Process Control Instruments and Field Devices
Flow, Pressure Level, Mass Flow, Radar,Differential Pressure, Temperature, pH, Conductivity, Density, Viscosity, Oxygen
Process Control Instruments and Field Devices
FMR533-AAXXJAC2RA
(199)

ENDRESS+HAUSER  FMR533-AAXXJAC2RA

EH Micropilot FMR533 Radar for high precision level measurement in custody transfer (up to 40m). DN150 to DN250 Process Connection. 4-wire HART communication. 450mm/20" Parabolic Antenna. 316L + PTFE main wetted parts. T12 Alu Housing IP65/68. ATEX, IECEx, FM and CSA approvals.

FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

FTL51H-AGW2DC1E4A
(243)

ENDRESS+HAUSER  FTL51H-AGW2DC1E4A

EH Liquiphant FTL51H Vibronic Point level switch with extension tube for liquids in food industry (hygienic). Hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

FTM52-AGG2F1A12AA
(253)

ENDRESS+HAUSER  FTM52-AGG2F1A12AA

EH Soliphant FTM52 Vibronic Point level switch with rope extension for fine-grained bulk solids measurement in hazardous areas. DN50 to DN100 Process Connection. SIL safety approval. ATEX, FM and CSA approvals.

CLM223-CD0005
(307)

ENDRESS+HAUSER  CLM223-CD0005

EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

COM253-DX0005
(313)

ENDRESS+HAUSER  COM253-DX0005

EH Liquisys COM253 Dissolved Oxygen field transmitter for use with COS41 and COS61 sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

FMU40-ANB1A2
(217)

ENDRESS+HAUSER  FMU40-ANB1A2

EH Prosonic FMU40 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 16ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. G/NPT 1 1/2" Process Connection. FM and CSA approvals.

CLS50-A1B1
(303)

ENDRESS+HAUSER  CLS50-A1B1

EH Indumax CLS50 Analog toroidal conductivity sensor for standard, hazardous and high-temperature chemistry applications. Inductive cell. PEEK or PFA material. Integrated Pt100 temperature sensor. IP67. ATEX, FM and CSA approvals.

FMU41-CNB1A2
(119)

ENDRESS+HAUSER  FMU41-CNB1A2

EH Prosonic FMU41 Ultrasonic Transmitter for non-contact Level Measurement. HART. PROFIBUS PA. Multilingual Plain Text Display. Easy remote operation. Suitable for explosion hazardous areas. IECEx Approval.

FQR56-AAAAAVEA1
(267)

ENDRESS+HAUSER  FQR56-AAAAAVEA1

EH Soliwave FQR56 Microwave barrier emitter for non-contact point level detection in bulk solids. Up to 100m measurement range. Suitable as level limit switch. ATEX, CSA and IECEx Approvals.

CLS21D-C1E1
(295)

ENDRESS+HAUSER  CLS21D-C1E1

EH Condumax CLS21D 2-electrode Digital conductive conductivity sensor for medium and high measuring ranges. Memosens technology. NPT 1" or G1 Process Connection. IP68. ATEX, FM and CSA Approvals.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

FTG20-AA14A1AA
(235)

ENDRESS+HAUSER  FTG20-AA14A1AA

EH Gammapilot FTG20 Radiometric Geiger-Mueller counter for non-contact point level detection with separate transmitter. Highest sensitivity. DPDT Relay. 4-20mA HART communication. ATEX, CSA and IECEx Approvals.

FMP53-IAAAAAEBADTDJ
(135)

ENDRESS+HAUSER  FMP53-IAAAAAEBADTDJ

EH Levelflex FMP53 Guided wave radar for Level measurement in hygienic applications. Rod probe (electro polished). HistoROM data management. International explosion protection certificates. IECEx approval.

FMP57-AAAAAAAFA4GGE
(207)

ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

5W4C25-AAALHA0AUA1KGA
(137)

ENDRESS+HAUSER  5W4C25-AAALHA0AUA1KGA

EH Proline Promag W 400 Electromagnetic Flowmeter Sensor with corrosion protection and transmitter for Water and Wastewater. 9 dm3/min to 110000 m3/h measuring range. DN 25 Nominal Diameter. IP68. Polycarbonate or aluminum housing. Includes 4-line backlit display, 4-20ma and switch outputs and Integrated data logger. Optional Modbus RS485 communication. cCSAus approval.

CUS71D-AA1A
(315)

ENDRESS+HAUSER  CUS71D-AA1A

EH Turbimax CUS71D Ultrasonic Memosens Immersion Smart sensor for sedimentation tanks. 0.3 - 10 m measurement range. ABS Epoxy sensor. IP68. CE certification.

CAS40D-AA1A1A1
(339)

ENDRESS+HAUSER  CAS40D-AA1A1A1

EH ISEmax CAS40D digital memosens Ion-sensitive sensor for continuous measurement of ammonium and nitrate in the wastewater industry. Self-cleaning functionality. Temperature sensor.

8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.