EH Levelflex FMP53 Guided wave radar for Level measurement in hygienic applications. Rod probe. HistoROM data management. International explosion protection certificates. INMETRO approval.

Part# with Options:        FMP53-MAAAAADBADTDJ
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMR51 & FMR53 (INMETRO)
Power Supply
(2) Power Supply for EH FMP Level Radars
Display & Operation
(3) Display & Operation for EH FMP Level Radars
Housing
(4) Housing for EH FMP50/53
Electrical Connection
(5) Electrical Connection for EH FMP Level Radars
Probe Length
(6) Probe Length for EH FMP53 (rod 0.31in 316L)
Seal
(7) Seal for EH FMP53
Process Connection
(8) Process Connection for EH FMP53

  Availability 5 Days  ]

Application
  • Rod probe
  • Process connections for hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO, Varivent N, SMS)
  • Temperature: 20 to +150 C (4 to +302 F)
  • Pressure: 1 to +16 bar (14.5 to +232 psi)
  • Maximum measuring range: Rod 6 m (20 ft)
  • Accuracy: 2 mm (0.08 in)
  • International explosion protection certificates; WHG; EN10204-3.1; EHEDG; 3-A; CoC ASME-BPE
  • Linearity protocol (3-point, 5-point)
Your benefits
  • Reliable measurement even for changing product and process conditions
  • HistoROM data management for easy commissioning, maintenance and diagnostics
  • Highest reliability due to Multi-Echo Tracking
  • Hardware and software developed according to IEC 61508 (up to SIL3)
  • Seamless integration into control or asset management systems
  • Intuitive user interface in national languages
  • Easy proof test for SIL and WHG
Measuring principle

The Levelflex is a "downward-looking" measuring system that functions according to the ToF method (ToF = Time of Flight). The distance from the reference point to the product surface is measured. High-frequency pulses are injected to a probe and led along the probe. The pulses are reflected by the product surface, received by the electronic evaluation unit and converted into level information. This method is also known as TDR (Time Domain Reflectometry).

Specifications
Measuring PrincipleGuided radar
Characteristic / ApplicationPremium device. Hygiene
Rod probe, ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head.
Supply / Communication2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
AccuracyRod probe:+/- 2 mm (0.08 in)
Ambient temperature-40...+80 C
(-40...+176 F)
Process temperature20...+150 C
( 4...+302 F)
Process pressure absolute / max. overpressure limitVacuum...16 bar
(Vacuum...232 psi)
Main wetted partsRod probe:
304, 304L, 316L, PEEK
Process connectionThread:
M24
Process connection hygienicTri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
Sensor lengthRod probe: 6 m (20 ft)
Max. measurement distanceRod: 6 m (20 ft)
Min DK>1.6
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC
Safety approvalsOverfill prevention WHG
SIL
Design approvalsEN 10204-3.1
Hygienic approvals3A, EHEDG
CoC ASME-BPE
OptionsSensor remote with 3 m/9 ft or 6 m/18 ft cable
Weld-in adpater


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> RADAR TRANSMITTERS > INMETRO :    5 Items found.
FMU41-7NB1A2
(121)

ENDRESS+HAUSER  FMU41-7NB1A2

EH Prosonic FMU41 Ultrasonic Transmitter for non-contact Level Measurement. HART. PROFIBUS PA. Multilingual Plain Text Display. Easy remote operation. Suitable for explosion hazardous areas. INMETRO Approval.

FMP53-MAAAAAEBADTDJ
(136)

ENDRESS+HAUSER  FMP53-MAAAAAEBADTDJ

EH Levelflex FMP53 Guided wave radar for Level measurement in hygienic applications. Rod probe (electro polished). HistoROM data management. International explosion protection certificates. INMETRO approval.

FMR51-MAAAAABAA5CFJ
(109)

ENDRESS+HAUSER  FMR51-MAAAAABAA5CFJ

EH Micropilot FMR51 Free space radar for Level measurement in liquids. For high temperature and high pressure conditions. Horn antenna. International explosion protection certificates. INMETRO approval. DN50 (Metric) Process Connection.

FMR51-MAAAAABAA5AFJ
(108)

ENDRESS+HAUSER  FMR51-MAAAAABAA5AFJ

EH Micropilot FMR51 Free space radar for Level measurement in liquids. For high temperature and high pressure conditions. Horn antenna. International explosion protection certificates. INMETRO approval. NPS (US) Process Connection.

FMR53-MAAAAACACFJ
(113)

ENDRESS+HAUSER  FMR53-MAAAAACACFJ

EH Micropilot FMR53 Free space radar for Level measurement in liquids. Rod antenna. HistoROM data management. International explosion protection certificates. INMETRO approval. DN50 (Metric) Process Connection.