Process Control Instruments, Field Devices and Industrial Automation
SKU# (143)

ENDRESS+HAUSER  7F2B15-AAAACA1AASK




ENDRESS+HAUSER 7F2B15-AAAACA1AASK (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Proline Prowirl F 200 Vortex Flowmeter with wet steam detection for heavy duty applications. Compact or remote version. 0.16 to 2412 m3/h measuring range. DN15 Nominal Diameter. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display. ATEX, IECEx and cCSAus approvals.

Part# with Options:        7F2B15-AAAACA1AASK
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH Prowirl F200
Output/Input
(2) Output/Input for EH Prowirl F200
Display & Operation
(3) Display & Operation for EH Prowirl F200
Housing
(4) Housing for EH Prowirl F200
Electrical Connection
(5) Electrical Connection for EH Prowirl B200
Sensor Version
(6) Sensor Version for EH Prowirl F200
Process Connection
(7) Process Connection for EH Prowirl F200
Calibration Flow
(8) Calibration Flow for EH Prowirl B200

  Availability 10 Days  ]

Application
  • Preferred measuring principle for wet/saturated/ superheated steam, gases & liquids (also cryogenic)
  • Suitable for a wide range of applications; optimized for steam applications
Device properties
  • Wet steam detection and measurement for DN 25 to 100 (1 to 4")
  • Inlet run compensation
  • Face-to-face length according to industry standard
  • Display module with data transfer function
  • Robust dual-compartment housing
  • Plant safety: worldwide approvals (SIL, Haz. area)
Your benefits
  • Integrated temperature measurement for mass/energy flow of saturated steam
  • Highest process safety dualsens version enables redundant measurement
  • High availability proven robustness, resistance to vibrations, temperature shocks & water hammer
  • No maintenance lifetime calibration
  • Convenient device wiring separate connection compartment
  • Safe operation no need to open the device due to display with touch control, background lighting
  • Integrated verification Heartbeat TechnologyTM
Measuring principle

The measuring system operates on the principle of transit time difference. In this measurement method, acoustic (ultrasonic) signals are transmitted between two sensors. The signals are sent in both directions, i.e. the sensor in question works as both a sound transmitter and a sound receiver.

As the propagation velocity of the waves is less when the waves travel against the direction of flow than along the direction of flow, a transit time difference occurs. This transit time difference is directly proportional to the flow velocity.

The measuring system calculates the volume flow of the fluid from the measured transit time difference and the pipe cross-sectional area. In addition to measuring the transit time difference, the system simultaneously measures the sound velocity of the fluid. This additional measured variable can be used to distinguish different fluids or as a measure of product quality.

The measuring device can be configured onsite to suit the specific application using Quick Setup menus.

Measuring Principle Ultrasonic flow
Measuring Principle Vortex
Product headline The flowmeter for accurate steam flow measurement with wet steam detection, available as compact or remote version. Integrated temp. measuring for mass/ energy flow of saturated steam. Suitable for a wide range of applications; optimized for steam applications.
Sensor features Highest process safety dualsens version enables redundant measurement. High availability proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance lifetime calibration. Wet steam detection and measurement for DN 25 to 100 (1 to 4"). Inlet run compensation.
Transmitter features Convenient device wiring separate connection compartment. Safe operation no need to open the device due to display with touch control, background lighting. Integrated verification Heartbeat Technology. Display module with data transfer function. Robust dual‐compartment housing.
Nominal diameter range DN 15 to 300 ( to 12")
Wetted materials Measuring tube: 1.4408 (C3FM); CX2MW similar to Alloy C22, 2.4602
DSC sensor: 1.4435 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
Connection: 1.4404 (F316/F316L); CX2MW similar to Alloy C22, 2.4602; 1.4408 (CF3M)
Measured variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measured error Volume flow (liquid): 0.75 %
Volume flow (steam, gas): 1.00 %
Mass flow (liquid): 0.85%
Mass flow (steam, gas): 1.7 %
Measuring range Liquid: 0.16 to 2412 m/h (0.09 to 1420 ft/min)
depending on medium: water with 1 bar a, 20 C (14.5 psi a, 68 F)
Steam, gas: 2 to 32 166 m/h (1.18 to 18 932 ft/min)
depending on medium: steam with 180 C, 10 bar a (356 F, 145 psi a); air with 25 C, 4.4 bar a (77 F, 63.8 psi a)
Max. process pressure PN 40, Class 300, 20K
Medium temperature range Standard: 40 to +260 C (40 to +500 F)
High/low temperature (option): 200 to +400 C (328 to +752 F)
High/low temperature (on request): 200 to +450 C (328 to +842 F)
Ambient temperature range Compact version (standard): 40 to +80 C (40 to +176 F)
Compact version (option): 50 to +80 C (58 to +176 F)
Remote version (standard): 40 to +85 C (40 to +185 F)
Remote version (option): 50 to +85 C (58 to +185 F)
Sensor housing material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material AlSi10Mg, coated; 1.4404 (316L)
Degree of protection Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs Current input 4‐20 mA (passive)
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals ATEX, IECEx, cCSAus
Other approvals and certificates
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 Section 7.6 a (TV attestation)
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)

  • FLOW > BATCH CONTROLLERS
    RA33-AA1-AA EH RA33 Batch Controller for flow and control output signals. 1 4-20mA or Pulse Flow input, 1 RTD or 4-20mA Temperature input, 1 4-20mA Density input, 2 digital inputs, 2 open collector and 2 relay outputs. Temperature and density compensation function. I..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> VORTEX TRANSMITTERS > HAZARDOUS LOCATIONS :    11 Items found.
6BABL1-AADAAAASAGA1G
(144)

ENDRESS+HAUSER  6BABL1-AADAAAASAGA1G

EH Proline t-mass B150 Thermal Mass Flowmeter for measurement on large pipelines or rectangular ventilation ducts. 20 to 720 000 kg/h measuring range. DN80 Nominal Diameter. 18-30VDC. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display with push buttons. ATEX, IECEx and 0cCSAus approvals.

DTI200-A16A1A
(148)

ENDRESS+HAUSER  DTI200-A16A1A

EH Magphant Electromagnetic compact Flowmeter and Limit Switch for repeatable flow monitoring. 0...56'550 m3/h measuring range. DN15 to DN2000 Nominal Diameter. IP66 NEMA 4X Enclosure. Includes 4-20mA and relay outputs. FM and CSA approvals.

5H1B02-AADBAAA00000A
(139)

ENDRESS+HAUSER  5H1B02-AADBAAA00000A

EH Proline Promag H 100 Electromagnetic Flowmeter for the smallest flow rates with ultra compact transmitter. 0.06 dm3/min to 600 m3/h measuring range. DN 2 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24 VDC. Includes 4-20ma and switch outputs. Optional 4 line backlit display and Modbus RS485 communication. ATEX, IECEx, cCSAus, INMETRO and EAC approvals.

5W4C25-AAALHA0AUA1KGA
(137)

ENDRESS+HAUSER  5W4C25-AAALHA0AUA1KGA

EH Proline Promag W 400 Electromagnetic Flowmeter Sensor with corrosion protection and transmitter for Water and Wastewater. 9 dm3/min to 110000 m3/h measuring range. DN 25 Nominal Diameter. IP68. Polycarbonate or aluminum housing. Includes 4-line backlit display, 4-20ma and switch outputs and Integrated data logger. Optional Modbus RS485 communication. cCSAus approval.

5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

9B2B80-AAAACA1W0W1
(141)

ENDRESS+HAUSER  9B2B80-AAAACA1W0W1

EH Proline Prosonic Flow B200 Ultrasonic Flowmeter for biogas measurement with loop-powered technology. 1 to 30 m/s measuring range. DN 80 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display. ATEX, IECEx, cCSAus, NEPSI and INMETRO approvals.

8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8FF08-AG15AABAA10N
(145)

ENDRESS+HAUSER  8FF08-AG15AABAA10N

EH CNGmass Coriolis Flowmeter with the highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8F1B08-AADBAAASAAASA
(140)

ENDRESS+HAUSER  8F1B08-AADBAAASAAASA

EH Proline Promass F100 Coriolis Flowmeter with premium accuracy, robustness and ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

83E50-AAASAAAAAAAA
(189)

ENDRESS+HAUSER  83E50-AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

8DF08-AG15AAAAA70M
(146)

ENDRESS+HAUSER  8DF08-AG15AAAAA70M

EH CNGmass DCI Coriolis Flowmeter. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.