EH Proline t-mass B150 Thermal Mass Flowmeter for measurement on large pipelines or rectangular ventilation ducts. 20 to 720 000 kg/h measuring range. DN80 Nominal Diameter. 18-30VDC. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display with push buttons. ATEX, IECEx and 0cCSAus approvals.

Part# with Options:        6BABL1-AADAAAASAGA1G
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH Proline t-mass B150
Output
(2) Output for EH Proline t-mass B150
Display & Operation
(3) Display & Operation for EH Proline t-mass B150
Electrical Connection
(4) Electrical Connection for EH Proline t-mass B150
Process Connection
(5) Process Connection for EH Proline t-mass B150
Calibration Flow
(6) Calibration Flow for EH Proline t-mass B150

  Availability 3 Weeks  ]

Area of Application
  • Cost-effective measuring device for different utility gas applications
  • System optimization due to targeted monitoring of utility gases
  • Leakage detection in gas networks
  • Suitable for in-house consumption accountancy
Device properties
  • Direct mass flow measurement (kg/h, lbs/h, Scf/min, Nm 3 , etc.)
  • Selection of gases: air, carbon dioxide, nitrogen and argon
  • Nominal diameters: DN 80 to 1500 (3 to 60")
  • 3⁄4"- and 1" compression fittings
  • Process temperature up to +100 C (+212 F)
  • Process pressure: 500 mbar a to 20 bar g (7.25 psi a to 290 psi g)
  • Calibration accuracy up to 3% o.r. and operable flow range up to 150:1
  • 4-20 mA HART, pulse/frequency/status
  • cCSAus Cl. 1 Div. 2, CRN
  • IP 66/67
Your benefits

The device enables direct measurement of the mass flow of utility gases. Minimum maintenance and negligible pressure loss drive down operating costs.

Sizing - correct product selection
Applicator - the reliable, easy-to-use tool for selecting measuring devices for every application
Installation - simple and efficient "Hot tap" mounting tool for installation and removal of device under operating conditions
Commissioning - reliable and intuitive

  • Intuitive configuration and simple operation
  • Preconfigured in accordance with individual requirements

Operation - Multivariable output values measured: mass flow, corrected volume flow, FAD volume flow and temperature
Life Cycle Management (W@M) for your plant

Measuring principle

The thermal measuring principle is based on the cooling of a heated resistance thermometer (PT100), from which heat is extracted by the passing gas. The gas passes two PT100 resistance thermometers in the measurement section. One of these is used in the conventional way as a temperature probe, while the other serves as a heating element. The temperature probe monitors and records the effective process temperature while the heated resistance thermometer is kept at a constant differential temperature (compared to the measured gas temperature) by controlling the electrical current used by the heating element. The greater the mass current passing over the heated resistance thermometer, the greater the extent to which cooling takes place and therefore the stronger the current required to maintain a constant differential temperature. This means that the heat current measured is an indicator of the mass flow rate of the gas.

Measuring Principle Thermal
Product headline The flowmeter for cost‐effective measurement and easy monitoring of utility gases. Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
Sensor features Optimal process monitoring easy measurement even at low pressures and flow velocities. Cost‐effective measurement easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending multivariable measurement. Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption.
Transmitter features Fast and efficient commissioning guided operating menus. High plant availability self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output.
Nominal diameter range DN 80 to 1500 (3 to 60")
Wetted materials Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G
Measured variables Mass flow, temperature, corrected volume flow, FAD volume flow
Max. measured error 3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
Measuring range 20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
Max. process pressure 20 bar g (290 psi g)
Medium temperature range 40 to +100 C (40 to +212 F)
Ambient temperature range 40 to +60 C (40 to +140 F)
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line display with push Buttons
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
Power supply DC 18 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates CRN

  • FLOW > BATCH CONTROLLERS
    RA33-AA1-AA EH RA33 Batch Controller for flow and control output signals. 1 4-20mA or Pulse Flow input, 1 RTD or 4-20mA Temperature input, 1 4-20mA Density input, 2 digital inputs, 2 open collector and 2 relay outputs. Temperature and density compensation function. I..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> THERMAL TRANSMITTERS > HAZARDOUS LOCATIONS :    11 Items found.
DTI200-A16A1A
(148)

ENDRESS+HAUSER  DTI200-A16A1A

EH Magphant Electromagnetic compact Flowmeter and Limit Switch for repeatable flow monitoring. 0...56'550 m3/h measuring range. DN15 to DN2000 Nominal Diameter. IP66 NEMA 4X Enclosure. Includes 4-20mA and relay outputs. FM and CSA approvals.

5H1B02-AADBAAA00000A
(139)

ENDRESS+HAUSER  5H1B02-AADBAAA00000A

EH Proline Promag H 100 Electromagnetic Flowmeter for the smallest flow rates with ultra compact transmitter. 0.06 dm3/min to 600 m3/h measuring range. DN 2 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24 VDC. Includes 4-20ma and switch outputs. Optional 4 line backlit display and Modbus RS485 communication. ATEX, IECEx, cCSAus, INMETRO and EAC approvals.

7F2B15-AAAACA1AASK
(143)

ENDRESS+HAUSER  7F2B15-AAAACA1AASK

EH Proline Prowirl F 200 Vortex Flowmeter with wet steam detection for heavy duty applications. Compact or remote version. 0.16 to 2412 m3/h measuring range. DN15 Nominal Diameter. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display. ATEX, IECEx and cCSAus approvals.

5W4C25-AAALHA0AUA1KGA
(137)

ENDRESS+HAUSER  5W4C25-AAALHA0AUA1KGA

EH Proline Promag W 400 Electromagnetic Flowmeter Sensor with corrosion protection and transmitter for Water and Wastewater. 9 dm3/min to 110000 m3/h measuring range. DN 25 Nominal Diameter. IP68. Polycarbonate or aluminum housing. Includes 4-line backlit display, 4-20ma and switch outputs and Integrated data logger. Optional Modbus RS485 communication. cCSAus approval.

5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

9B2B80-AAAACA1W0W1
(141)

ENDRESS+HAUSER  9B2B80-AAAACA1W0W1

EH Proline Prosonic Flow B200 Ultrasonic Flowmeter for biogas measurement with loop-powered technology. 1 to 30 m/s measuring range. DN 80 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display. ATEX, IECEx, cCSAus, NEPSI and INMETRO approvals.

8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8FF08-AG15AABAA10N
(145)

ENDRESS+HAUSER  8FF08-AG15AABAA10N

EH CNGmass Coriolis Flowmeter with the highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8F1B08-AADBAAASAAASA
(140)

ENDRESS+HAUSER  8F1B08-AADBAAASAAASA

EH Proline Promass F100 Coriolis Flowmeter with premium accuracy, robustness and ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

83E50-AAASAAAAAAAA
(189)

ENDRESS+HAUSER  83E50-AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

8DF08-AG15AAAAA70M
(146)

ENDRESS+HAUSER  8DF08-AG15AAAAA70M

EH CNGmass DCI Coriolis Flowmeter. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.