InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

Online Shop for Process Instrumentation by Endress+Hauser supported by our 20+ years of experience with PLC-based industrial automation and control instrumentation.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(146) Be the First to Review this Item

ENDRESS-HAUSER  8DF08AG15AAAAA70M

FLOW / CORIOLIS TRANSMITTERS
HAZARDOUS LOCATIONS

$14,968.96     Availability: 3 Weeks
 Information Request
 Shipping Rates
 Volume discount
      



ENDRESS-HAUSER 8DF08AG15AAAAA70M (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH CNGmass DCI Coriolis flowmeter with seamless system integration. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.

Part# with Options:        8DF08AG15AAAAA70M
Price with Options:        14,968.96

Options:    

Measure Tube Material
(1) Measure Tube Material for EH CNGmass & LPGmass
Additional Test
(2) Additional Test for EH CNGmass
Calibration
(3) Calibration for EH CNGmass DCI
Approval
(4) Approval for EH CNGmass DCI
Housing
(5) Housing for EH CNGmass DCI
Cable Entry
(6) Cable Entry for EH CNGmass DCI
Power Supply & Display
(7) Power Supply & Display for EH CNGmass
Custody Transfer Approval
(8) Custody Transfer Approval for EH CNGmass DCI
Output/Input
(9) Output/Input for EH CNGmass DCI

  Availability 3 Weeks  ]

Area of Application
  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • Accurate measurement of compressed natural gas (CNG) in high-pressure refueling applications
Device properties
  • Flow rates up to 150 kg/min (330 lb/min)
  • Process pressure up to 350 bar (5080 psi)
  • Rupture disc available
  • Device in compact or remote version
  • Flexible outputs and Modbus RS485
  • Transmitter for custody transfer
Your benefits
  • Excellent operational safety - reliable under extreme process conditions
  • Fewer process measuring points multivariable measurement (flow, density, temperature)
  • Space-saving installation no in/outlet run needs
  • High flexibility in system integration - wide range of communication interfaces
  • Fast commissioning pre-configured devices
  • Automatic recovery of data for servicing
Measuring principle

The measuring principle is based on the controlled generation of Coriolis forces. These forces are always present when both translational and rotational movements are superimposed.

The amplitude of the Coriolis force depends on the moving mass Δm, its velocity v in the system, and thus on the mass flow. Instead of a constant angular velocity ω, oscillation occurs.

In the sensor, two parallel measuring tubes containing flowing fluid oscillate in antiphase, acting like a tuning fork. The Coriolis forces produced at the measuring tubes cause a phase shift in the tube oscillations (see illustration):

  • At zero flow, in other words when the fluid is at a standstill, the tubes oscillate in phase (1).two
  • Mass flow causes deceleration of the tube oscillation at the inlet (2) and acceleration at the outlet (3).

The phase difference (A-B) increases with increasing mass flow. Electrodynamic sensors register the tube oscillations at the inlet and outlet. System balance is ensured by the antiphase oscillation of the two measuring tubes. The measuring principle works independently of temperature, pressure, viscosity, conductivity and flow profile.

Measuring Principle Coriolis
Product headline The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
Sensor features Excellent operational safety reliable under extreme process conditions. Fewer process measuring points multivariable measurement (flow, density, temp). Space‐saving installation no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
Transmitter features High flexibility in system integration wide range of communication interfaces. Fast commissioning preconfigured devices. Automatic recovery of data for servicing. Device in compact or remote version. Flexible outputs and Modbus RS485.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measured error Mass flow: 0.5 % of batch
Measuring range 0 to 150 kg/min (0 to 330 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range 50 to +150 C (58 to +302 F)
Ambient temperature range Standard: 20 to +60 C (4 to +140 F)
Option: 40 to +60 C (40 to +140 F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive), phase‐shifted pulse
Relay
Inputs 1 modular input: status
Digital communication HART, Modbus RS485
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer
CRN


B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CORIOLIS TRANSMITTERS > HAZARDOUS LOCATIONS :    4 Items found.
8F1B08AADBAAASAAASA (140) ENDRESS-HAUSER  8F1B08AADBAAASAAASA

EH Proline Promass F100 Coriolis flowmeter with premium accuracy, robustness and an ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

  

$7,713.24        

 
83E50AAASAAAAAAAA (189) ENDRESS-HAUSER  83E50AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

  

$8,125.92        

 
8FE08AAASAABAA10N (147) ENDRESS-HAUSER  8FE08AAASAABAA10N

EH LPGmass Coriolis flowmeter with easy system integration for measurement of LPG for dispensing and truck unloading. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

  

$9,072.33        

 
8FF08AG15AABAA1AN (145) ENDRESS-HAUSER  8FF08AG15AABAA1AN

EH CNGmass Coriolis flowmeter with easy system integration and highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

  

$10,138.51        

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
8DF08AG15AAAAA70M

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Contact Us | Get a Quote | Downloads | Sell Here | Mobile View Mobile view |   LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site
|