Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER DTI200-A16A1A (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Magphant Electromagnetic compact Flowmeter and Limit Switch for repeatable flow monitoring. 0...56'550 m3/h measuring range. DN15 to DN2000 Nominal Diameter. IP66 NEMA 4X Enclosure. Includes 4-20mA and relay outputs. FM and CSA approvals.

Part# with Options:        DTI200-A16A1A
Price with Options:        Please Email us your request for quote   

Options:    

Pipe Diameter
(1) Pipe Diameter for EH Magphant
Process Connection
(2) Process Connection for EH Magphant
Cable Entry
(3) Cable Entry for EH Magphant
Approval
(4) Approval for EH Magphant

  Availability 4 Days  ]

Monitoring and measurement
  • Flow monitoring with selectable limit values (relay output)
  • Flow measurement via 4...20 mA current output
Safe operation
  • Reliable monitoring (4 mA) even with empty piping
  • EMC tested according to IEC
  • Measuring system self-monitoring
  • Integrated testing to check correct functioning of the electronics
Universal application
  • One compact flow monitor for all applications
  • Mounted in
    • Steel piping from DN 25
    • Plastic piping from DN 15
Simple operation
  • Switchpoint setting via rotary switch
  • Local potentiometer setting of full scale value
  • Can be set-up before installation
Areas of application

Flow information is often required to ensure a process is running correctly and that preset limit values are not exceeded. The Magphant flow monitor reliably provides the necessary information on flow in your piping. The electromagnetic principle used determines the flow velocity of the conductive liquid at the tip of the sensor.

Measuring principle

In accordance with Faraday’s law of electromagnetic induction, a voltage is induced in a conductor that is moved through a magnetic field. In the electromagnetic principle of measurement the flowing and electrically conductive fluid represents the moving conductor. The induced voltage is proportional to the flow velocity and is fed to the amplifier by a pair of electrodes. Microprocessor-controlled electronics, with a stable zero-point, convert the voltage into an analogue 4...20-mA output signal.

Measuring Principle Electromagnetic
Product headline Volume flow monitoring of conductive liquids by means of limit value setting  
Nominal diameter range DN15...DN2000
1/2"...80"
Max. measured error 2%
Measuring range 0...56'550 m3/h
Max. process pressure 0...16 bar abs
Medium temperature range -20...+120°C
(-4...+248°F)
Degree of protection IP 66
NEMA 4x
Type 4X
Display/Operation Test function
Outputs 4...20 mA
Relay
Inputs -
Hazardous area approvals FM
CSA

  • FLOW > BATCH CONTROLLERS
    RA33-AA1-AA EH RA33 Batch Controller for flow and control output signals. 1 4-20mA or Pulse Flow input, 1 RTD or 4-20mA Temperature input, 1 4-20mA Density input, 2 digital inputs, 2 open collector and 2 relay outputs. Temperature and density compensation function. I..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ELECTROMAGNETIC TRANSMITTERS > HAZARDOUS LOCATIONS :    11 Items found.
6BABL1-AADAAAASAGA1G
(144)

ENDRESS+HAUSER  6BABL1-AADAAAASAGA1G

EH Proline t-mass B150 Thermal Mass Flowmeter for measurement on large pipelines or rectangular ventilation ducts. 20 to 720 000 kg/h measuring range. DN80 Nominal Diameter. 18-30VDC. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display with push buttons. ATEX, IECEx and 0cCSAus approvals.

5H1B02-AADBAAA00000A
(139)

ENDRESS+HAUSER  5H1B02-AADBAAA00000A

EH Proline Promag H 100 Electromagnetic Flowmeter for the smallest flow rates with ultra compact transmitter. 0.06 dm3/min to 600 m3/h measuring range. DN 2 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24 VDC. Includes 4-20ma and switch outputs. Optional 4 line backlit display and Modbus RS485 communication. ATEX, IECEx, cCSAus, INMETRO and EAC approvals.

7F2B15-AAAACA1AASK
(143)

ENDRESS+HAUSER  7F2B15-AAAACA1AASK

EH Proline Prowirl F 200 Vortex Flowmeter with wet steam detection for heavy duty applications. Compact or remote version. 0.16 to 2412 m3/h measuring range. DN15 Nominal Diameter. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display. ATEX, IECEx and cCSAus approvals.

5W4C25-AAALHA0AUA1KGA
(137)

ENDRESS+HAUSER  5W4C25-AAALHA0AUA1KGA

EH Proline Promag W 400 Electromagnetic Flowmeter Sensor with corrosion protection and transmitter for Water and Wastewater. 9 dm3/min to 110000 m3/h measuring range. DN 25 Nominal Diameter. IP68. Polycarbonate or aluminum housing. Includes 4-line backlit display, 4-20ma and switch outputs and Integrated data logger. Optional Modbus RS485 communication. cCSAus approval.

5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

9B2B80-AAAACA1W0W1
(141)

ENDRESS+HAUSER  9B2B80-AAAACA1W0W1

EH Proline Prosonic Flow B200 Ultrasonic Flowmeter for biogas measurement with loop-powered technology. 1 to 30 m/s measuring range. DN 80 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display. ATEX, IECEx, cCSAus, NEPSI and INMETRO approvals.

8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8FF08-AG15AABAA10N
(145)

ENDRESS+HAUSER  8FF08-AG15AABAA10N

EH CNGmass Coriolis Flowmeter with the highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8F1B08-AADBAAASAAASA
(140)

ENDRESS+HAUSER  8F1B08-AADBAAASAAASA

EH Proline Promass F100 Coriolis Flowmeter with premium accuracy, robustness and ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

83E50-AAASAAAAAAAA
(189)

ENDRESS+HAUSER  83E50-AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

8DF08-AG15AAAAA70M
(146)

ENDRESS+HAUSER  8DF08-AG15AAAAA70M

EH CNGmass DCI Coriolis Flowmeter. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.