Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CLS30-D1C4A (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Condumax W CLS30 2-electrode conductivity sensor for waste water and concentrate applications. Pt100 temperature sensor. 0,1-200,0mS/cm measuring range. 10ft cable connection. PP/PTFE Material. DN25 Process connection. IP65. ATEX and qualitity certifications.

Part# with Options:        CLS30-D1C4A
Price with Options:        Please Email us your request for quote   

Options:    

Process Connection
(1) Process Connection for EH Condumax W CLS30

  Availability 4 Days  ]

Application

Measurements in media of high or medium conductivities:

  • Process water
  • Wastewater treatment
  • Concentrate monitoring

The cell constant k of the sensor is 10 cm 1 . The measuring range reaches from 0.1 mS/cm to 200 mS/cm.

Sensors with temperature sensors are used together with conductivity transmitters equipped with automatic temperature compensation:

  • Mycom S CLM153
  • Liquisys M CLM223/253
  • Liquiline M CM42
Your benefits
  • Various designs guarantee optimum adaptation to the process conditions and
  • methods of installation
  • Installation in pipes or flow chambers
  • High chemical, thermal and mechanical stability
  • Compact design
  • Quality certificate with statement of the individual cell constant
Measuring Principle

The conductivity of liquids is measured with the following measurement setup: Two electrodes are immersed in the medium. An AC voltage is applied to these electrodes which generates a current in the medium.

The electric resistance or its reciprocal value, the conductance G, is calculated according to Ohms law. The specific conductivity κ is determined using the cell constant k that is dependent on the sensor geometry.

Measuring Principle Conductive
Application Water, concentrate
Characteristic 2-electrode system for controlling of industrial water or concentrates.
Measurement range k=10: 0,1 mS/cm - 200 mS/cm
Measuring principle Conductiv conductivity cell with graphite electrodes.
Design Punctual arranged graphite electrodes under PTFE protective cover.
Material Cell shaft: PTFE / PP
Electrode: graphite
Temperature sensor: titanium
Dimension Diameter: 22 mm
(0.85 inch)
Lenghth: 105 mm or 120 mm
(4.09 inch or 4.68 inch)
Process temperature max. 125C
(max. 257F)
Process pressure max. 16 bar
(max. 232 psi)
temperature sensor Pt100
Ex certification ATEX
Connection Process connection: G1", DN25,
fixed cable connection.
Ingres protection IP65
Additional Certifications Quality certification

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS :    20 Items found.
CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

CLS16-3C1A1P
(298)

ENDRESS+HAUSER  CLS16-3C1A1P

EH Condumax CLS16D 2-electrode Analog conductive conductivity sensor for hygienic applications. DN50 Process Connection. IP68. ATEX Approval.

CLS15D-A1A1
(271)

ENDRESS+HAUSER  CLS15D-A1A1

EH Condumax CLS15D 2-electrode Digital conductive conductivity sensor for applications in pure and ultrapure water. Memosens technology. 1/2"NPT or 3/4" NPT Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS50-A1B1
(303)

ENDRESS+HAUSER  CLS50-A1B1

EH Indumax CLS50 Analog toroidal conductivity sensor for standard, hazardous and high-temperature chemistry applications. Inductive cell. PEEK or PFA material. Integrated Pt100 temperature sensor. IP67. ATEX, FM and CSA approvals.

CLS21-C1E4A
(297)

ENDRESS+HAUSER  CLS21-C1E4A

EH Condumax CLS21 2-electrode Analog conductive conductivity sensor for medium and high measuring ranges. NPT 1" or G1 Process Connection. IP65/67. ATEX Approval.

CLS54-AMV5012
(302)

ENDRESS+HAUSER  CLS54-AMV5012

EH Indumax CLS54 Analog toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. DN40 to DN125 Process Connection. Integrated Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm Measurement range. IP68. ATEX, FM and CSA Approvals.

CLS52-A1MV1A1
(168)

ENDRESS+HAUSER  CLS52-A1MV1A1

EH Indumax CLS52 analog toroidal conductivity sensor for hygienic and sterile applications. Stainless steel Pt100 temperature sensor. Inductive measuring cell. 0 - 2000 mS/cm measuring range. IP67. ATEX and qualitity certifications.

CLS50D-AA1B11
(188)

ENDRESS+HAUSER  CLS50D-AA1B11

EH Indumax CLS50D Digital Memosens toroidal inductive conductivity sensor for hazardous and high-temperature chemistry applications. Corrosion and moisture resistant. PEEK or PFA material. Integrated Pt1000 temperature sensor. IP67. ATEX, CSA, FM and IECEx approvals.

CLS16D-3C1P1
(296)

ENDRESS+HAUSER  CLS16D-3C1P1

EH Condumax CLS16D 2-electrode Digital conductive conductivity sensor for hygienic applications. Memosens technology. DN50 Process Connection. IP68. ATEX, FM and CSA Approvals.

COS51D-AS800
(179)

ENDRESS+HAUSER  COS51D-AS800

EH Oxymax COS51D digital memosens amperometric sensor for the measurment of Oxygen (O2) in water, wastewater and utilities applications. Corrosion and moisture resistant. 0 to 2000 hPa measuring range. Thread NPT 3/4 Head. POM sensor body and membrane cap.

CLS21D-C1E1
(295)

ENDRESS+HAUSER  CLS21D-C1E1

EH Condumax CLS21D 2-electrode Digital conductive conductivity sensor for medium and high measuring ranges. Memosens technology. NPT 1" or G1 Process Connection. IP68. ATEX, FM and CSA Approvals.

COS22D-AA1A2B22
(178)

ENDRESS+HAUSER  COS22D-AA1A2B22

EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals.

OUSAF44-B0A0
(325)

ENDRESS+HAUSER  OUSAF44-B0A0

EH OUSAF44 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 254-365 nm wavelenght range. 0-2,5 AU measurement range. CIP, SIP, FM and ATEX approvals. IP65.

OUSAF22-B0C0A
(322)

ENDRESS+HAUSER  OUSAF22-B0C0A

EH OUSAF22 Optical sensor combined with OUA260 flow assembly for the measurement of color concentrations in liquids. 390-1100 nm wavelenght range. 0-2,5 AU measurement range. Embedded validation filter. FM and ATEX approvals.

OUSAF21-D0C0D1D1D1A1A
(321)

ENDRESS+HAUSER  OUSAF21-D0C0D1D1D1A1A

EH OUSAF21 Optical sensor for the measurement of low color concentrations in water. 390-1100 nm wavelength range. Embedded validation filter. Female NPT Process Connection. 0,75" nominal diameter. FM and ATEX approvals.

CPS341D-7A1B1
(292)

ENDRESS+HAUSER  CPS341D-7A1B1

EH Ceramax CPS341D Digital non-glass pH memosens electrode for hygienic applications. Corrosion, moisture resistant. 87psi max pressure. IP68. ATEX approval. 0-10pH; 0-140oC; 6 bar.