Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CLS52-A1MV1A1 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Indumax CLS52 analog toroidal conductivity sensor for hygienic and sterile applications. Stainless steel Pt100 temperature sensor. Inductive measuring cell. 0 - 2000 mS/cm measuring range. IP67. ATEX and qualitity certifications.

Part# with Options:        CLS52-A1MV1A1
Price with Options:        Please Email us your request for quote   

Options:    

Process Connection
(1) Process Connection for EH Indumax CLS52
Cable Connection
(2) Cable Connection for EH Indumax CLS52

  Availability 5 Days  ]

Application

The CLS52 conductivity sensors are intended specifically for use in the food industry. They are injection-molded and made from high-resistance PEEK, thereby meeting the strict hygienic requirements of the food industry.

  • Concentration control in the remaking of acids and alkalis
  • Phase separation of product/water and product/product mixtures in pipe systems
  • Monitoring and control of bottle cleaning systems
  • Product monitoring in breweries, dairies and the beverage industry
  • Control and monitoring of CIP systems
  • Use with Liquiline CM42 and Liquisys CLM223/253 transmitters; part of the Smartec CLD132 measuring system
Your benefits
  • Insensitive to electrode contamination and polarization thanks to inductive measuring principle
  • Food-safe and hygienic thanks to design without joints or crevices
  • Hydrodynamic sensor design for low flow resistance
  • Maintenance-free due to non-contact measurement
  • Very short temperature response time (t 90 <5s)
  • Easy installation directly in-line using standardized process connections common in the food industry
Measuring Principle

An oscillator (1) generates an alternating magnetic field in the primary coil (5), which induces a current flow (4) in the medium. The strength of the current depends on the conductivity and thus on the ion concentration in the medium. The current flow in the medium, in turn, generates a magnetic field in the secondary coil (3). The resulting induced current is measured by the receiver (2) and used to determine the conductivity.

Measuring Principle Inductive
Application Food, pharmaceuticals
Characteristic Hygienic inductive measuring cell for conductivity measurements, concentration control, CIP-control, cleaning and phase separation.
Measurement range 0 - 2000 mS/cm
Measuring principle Inductive conductivity measurement.
Design Hygienic inductive conductivity cell with an outside temperature sensor for a faster temperature reading.
Material Sensor: PEEK
Heat contact nut: stainless steel 1.4435
Sealing: Chemraz
Dimension Coil: outside diameter: appr. 47 mm inside diameter: appr. 15 mm
Process temperature max. 125C (short time up to 140C)
max. 257F (short time up to 284F)
Process pressure max. 16 bar at 90C
max. 232 psi at 194F
temperature sensor Integrated Pt100 in a heat contact nut
Ex certification ATEX
Connection Process connections: dairy fitting, Clamp, thread 1,5", Varivent, APV, Perlick, SMS cable: fixed cable connection.
Ingres protection IP67
Additional Certifications Calibration certification.

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..


  • ANALYSIS > TRANSMITTERS
    CLM223-CD0005 EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval...


  • ANALYSIS > TRANSMITTERS
    CLM223F-CF0005 EH Liquisys CLM223F Conductivity transmitter for use with all analog conductive and inductive sensors 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval...


  • ANALYSIS > TRANSMITTERS
    CLM253-CD0005 EH Liquisys CLM253 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS :    20 Items found.
CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

CLS16-3C1A1P
(298)

ENDRESS+HAUSER  CLS16-3C1A1P

EH Condumax CLS16D 2-electrode Analog conductive conductivity sensor for hygienic applications. DN50 Process Connection. IP68. ATEX Approval.

CLS15D-A1A1
(271)

ENDRESS+HAUSER  CLS15D-A1A1

EH Condumax CLS15D 2-electrode Digital conductive conductivity sensor for applications in pure and ultrapure water. Memosens technology. 1/2"NPT or 3/4" NPT Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS50-A1B1
(303)

ENDRESS+HAUSER  CLS50-A1B1

EH Indumax CLS50 Analog toroidal conductivity sensor for standard, hazardous and high-temperature chemistry applications. Inductive cell. PEEK or PFA material. Integrated Pt100 temperature sensor. IP67. ATEX, FM and CSA approvals.

CLS21-C1E4A
(297)

ENDRESS+HAUSER  CLS21-C1E4A

EH Condumax CLS21 2-electrode Analog conductive conductivity sensor for medium and high measuring ranges. NPT 1" or G1 Process Connection. IP65/67. ATEX Approval.

CLS54-AMV5012
(302)

ENDRESS+HAUSER  CLS54-AMV5012

EH Indumax CLS54 Analog toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. DN40 to DN125 Process Connection. Integrated Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm Measurement range. IP68. ATEX, FM and CSA Approvals.

CLS50D-AA1B11
(188)

ENDRESS+HAUSER  CLS50D-AA1B11

EH Indumax CLS50D Digital Memosens toroidal inductive conductivity sensor for hazardous and high-temperature chemistry applications. Corrosion and moisture resistant. PEEK or PFA material. Integrated Pt1000 temperature sensor. IP67. ATEX, CSA, FM and IECEx approvals.

CLS16D-3C1P1
(296)

ENDRESS+HAUSER  CLS16D-3C1P1

EH Condumax CLS16D 2-electrode Digital conductive conductivity sensor for hygienic applications. Memosens technology. DN50 Process Connection. IP68. ATEX, FM and CSA Approvals.

COS51D-AS800
(179)

ENDRESS+HAUSER  COS51D-AS800

EH Oxymax COS51D digital memosens amperometric sensor for the measurment of Oxygen (O2) in water, wastewater and utilities applications. Corrosion and moisture resistant. 0 to 2000 hPa measuring range. Thread NPT 3/4 Head. POM sensor body and membrane cap.

CLS21D-C1E1
(295)

ENDRESS+HAUSER  CLS21D-C1E1

EH Condumax CLS21D 2-electrode Digital conductive conductivity sensor for medium and high measuring ranges. Memosens technology. NPT 1" or G1 Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS30-D1C4A
(167)

ENDRESS+HAUSER  CLS30-D1C4A

EH Condumax W CLS30 2-electrode conductivity sensor for waste water and concentrate applications. Pt100 temperature sensor. 0,1-200,0mS/cm measuring range. 10ft cable connection. PP/PTFE Material. DN25 Process connection. IP65. ATEX and qualitity certifications.

COS22D-AA1A2B22
(178)

ENDRESS+HAUSER  COS22D-AA1A2B22

EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals.

OUSAF44-B0A0
(325)

ENDRESS+HAUSER  OUSAF44-B0A0

EH OUSAF44 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 254-365 nm wavelenght range. 0-2,5 AU measurement range. CIP, SIP, FM and ATEX approvals. IP65.

OUSAF22-B0C0A
(322)

ENDRESS+HAUSER  OUSAF22-B0C0A

EH OUSAF22 Optical sensor combined with OUA260 flow assembly for the measurement of color concentrations in liquids. 390-1100 nm wavelenght range. 0-2,5 AU measurement range. Embedded validation filter. FM and ATEX approvals.

OUSAF21-D0C0D1D1D1A1A
(321)

ENDRESS+HAUSER  OUSAF21-D0C0D1D1D1A1A

EH OUSAF21 Optical sensor for the measurement of low color concentrations in water. 390-1100 nm wavelength range. Embedded validation filter. Female NPT Process Connection. 0,75" nominal diameter. FM and ATEX approvals.

CPS341D-7A1B1
(292)

ENDRESS+HAUSER  CPS341D-7A1B1

EH Ceramax CPS341D Digital non-glass pH memosens electrode for hygienic applications. Corrosion, moisture resistant. 87psi max pressure. IP68. ATEX approval. 0-10pH; 0-140oC; 6 bar.