Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CLD132-PMV110AA1 (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Smartec CLD132 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt100 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. Relay output and 2-line display. IP67.

Part# with Options:        CLD132-PMV110AA1
Price with Options:        Please Email us your request for quote   

Options:    

Housing
(1) Housing for EH Smartec S CLD132
Process Connection
(2) Process Connection for EH Smartec S CLD132
Cable Entry
(3) Cable Entry for EH Smartec S CLD132
Power Supply
(4) Power Supply for EH Smartec S CLD132
Output
(5) Power Supply for EH Smartec S CLD132
Additional Option
(6) Additional Option for EH Smartec S CLD132

  Availability 4 Days  ]

Measuring system with inductive sensor for conductivity and concentration measurement in the food industry

Application
  • Product monitoring in breweries, dairies and the beverage industry
  • CIP system control
  • Phase separation of product/water and product/product mixtures in pipe systems
  • Alkali and acid concentration control in remaking
  • Monitoring and control of bottle cleaning systems
Your benefits
  • Transmitter housing made of stainless steel
  • Sensor made of highly resistant plastic (PEEK)
  • Sterilisable sensor
  • High measuring reliability due to extensive self-monitoring functions
  • Insensitive to polarisation and soiling
  • Versions with ultrafast temperature response (t 90 < 5 s) available
  • Sensor versions for all process connections used in hygienic applications
  • Various operating possibilities:
    • Keys
    • HART hand-held terminal
    • PROFIBUS PA/DP
    • PC with Commuwin II software
  • Large two-line display allows simultaneous display of measured value and temperature
  • Standard version extendable by function extension with remote parameter set switching (measuring range switching)
Measuring Principle

A generator (1) generates an alternating magnetic field in the primary coil (2) which induces a current in the medium (3). The strength of the induced current depends on the conductivity and thus the ion concentration of the medium. The current flow in the medium generates another magnetic field in the secondary coil (4). The resulting current induced in the coil is measured by the receiver (5) and processed to determine the conductivity.

Measuring Principle Inductive
Application - Alkali/acid concentration control - phase separation in pipe systems - monitoring and control of bottle cleaning systems - product monitoring in breweries, dairies and the beverage industry - CIP system control
Characteristic Compact measuring system for an inductive conductivity measurement special made for media with a high conductivity.
Measurement range 100 S/cm - 2000 mS/cm
Measuring principle Inductive measuring system including transmitter and sensor.
Design Compact transmitter made of stainless steel with an inductive sensor made of PEEK in a separate or compact version.
Material Housing: Stainless steel 1.4301 polished Window: Polycarbonate Sensor: PEEK, stainless steel 1.4435 Sealing: Chemraz
Process temperature max. 140C (max. 30 min.)
284F (max. 30 min.)
Process pressure max. 12 bar (90C)
(174 psi(194F))
temperature sensor Pt100
Ex certification No
Ingres protection IP67
Input One-channel transmitter incl. temperature.
Output Conductivity and temperature 0/4-20 mA, HART, Profibus.


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > GENERAL PURPOSE :    34 Items found.
CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CCS142D-AAS80
(330)

ENDRESS+HAUSER  CCS142D-AAS80

EH Chloromax CCS142D Digital disinfection memosens sensor for determining free chlorine in drinking water applications. Thread NPT 3/4 head. Amperometric and membrane-covered. Corrosion and moisture resistant. Integrated temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CUE26-A
(320)

ENDRESS+HAUSER  CUE26-A

EH Turbimax CUE26 Handheld turbidity meter for on-site quality control. White Light Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

OUSAF11-AA105A1A10A
(323)

ENDRESS+HAUSER  OUSAF11-AA105A1A10A

EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range.

CCS241-N
(328)

ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CCS141-N
(172)

ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

CAT810-AAD1A11
(337)

ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

CUE24-A
(318)

ENDRESS+HAUSER  CUE24-A

EH Turbimax CUE24 laboratory turbidity meter for quality control. White Light measurement. 0 - 1000 NTU measurement range. RS232 Output. ABS Housing.



 