Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CUE22-A1A (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Turbimax CUE22 online turbidity meter with sample condition adjustment. White Light Measurement. 0 - 100 NTU measurement range. 100-240 VAC. Automatic ultrasonic cleaning function. ABS Housing. IP66.

Please Email us your request for quote   

  Availability 4 Days  ]

Application

On-line continuous monitoring of clean water:

  • Drinking water
  • Treated process water
Your benefits
  • Versions with white light source and infrared light source
  • available
  • Fast and easy calibration
    • Complete primary calibration in less than 5 minutes
    • Verification in seconds
  • Reduced calibration costs and quick response times thanks to low
  • volume sample chamber
  • Automatic continuous ultrasonic cleaning (Autoclean) increases
  • cleaning intervals dramatically
  • Simple modular design
  • Easy to use and service
  • Affordable thanks to modular microprocessor based technology
  • Digital high-speed connections through RS-485 with Modbus Optional Features:
    • Flow chamber for bubble suppression
    • Reusable calibration kit
Optional Features:
  • Flow chamber for bubble suppression
  • Reusable calibration kit
Measuring principle Turbidity measurement

For turbidity measurement a light beam is sent through the medium and is diverted from its original direction by optically denser particels, e.g. solid matter particles.

Measuring Principle Single beam scattered light
Application Online continuous monitoring of clean water :
- Drinking water
- Treated process water
Installation Compact device for bypass-installations.
Characteristic " Versions with white light source
" Fast and easy calibration
" Complete primary calibration in less than 5 minutes
" Verification in seconds
" Reduced calibration costs and quick response times thanks to low volume sample chamber
" Automatic continuous ultrasonic cleaning (Autoclean)increases cleaning intervals dramatically
" Simple modular design
" Easy to use and service
" Affordable thanks to modular microprocessor based technology
" Digital high-speed connections through RS-485 with Modbus
Optional Features:
" Flow chamber for bubble suppression
" Reusable calibration kit

Measurement range 0 - 100 NTU
Measuring principle Turbidity measurement using standardised 90 scattered light method acc. to U.S.EPA180.1 (White Light)
Design The transmitted white light beam is scattered by the solid matter particles in the medium. The scattered light beams are detected by scattered light receivers which are arranged at an angle of 90 to the white light source.
Material Housing: ABS
Flow-through head: Nylon
Sample cuvette: Borosilicate glass
Sample cuvette seal: Silicone
Flow-through fittings: Polypropylene
Flow-through lock down pins: Stainless steel (AISI 304 or AISI 303)
Inlet tube: Stainless steel (AISI 316)
Dimension 347,16 x 207,65 x 196,85 mm
(13.66 x 8.17 x 7.75 inches)
Process temperature 1C - 50C
(34 - 122F)
Process pressure max. 13.78 bar / 200 psicontrolled by integral pressure regulator
Ingres protection IP66
Output 4-20mA, galvanic isolated
Bi-directional RS-485, Modbus optional.

  • TURBIDITY METERS > GENERAL PURPOSE
    CUE21-A1A EH Turbimax CUE21 online turbidity meter with sample condition adjustment. Infrared Measurement. 0 - 1000 NTU measurement range. 100-240 VAC. 4-20 mA or RS-485 output. Automatic ultrasonic cleaning function. ABS Housing. IP66...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> TURBIDITY METERS > GENERAL PURPOSE :    34 Items found.
CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CCS142D-AAS80
(330)

ENDRESS+HAUSER  CCS142D-AAS80

EH Chloromax CCS142D Digital disinfection memosens sensor for determining free chlorine in drinking water applications. Thread NPT 3/4 head. Amperometric and membrane-covered. Corrosion and moisture resistant. Integrated temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CUE26-A
(320)

ENDRESS+HAUSER  CUE26-A

EH Turbimax CUE26 Handheld turbidity meter for on-site quality control. White Light Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

OUSAF11-AA105A1A10A
(323)

ENDRESS+HAUSER  OUSAF11-AA105A1A10A

EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range.

CCS241-N
(328)

ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CCS141-N
(172)

ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

CAT810-AAD1A11
(337)

ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

CUE24-A
(318)

ENDRESS+HAUSER  CUE24-A

EH Turbimax CUE24 laboratory turbidity meter for quality control. White Light measurement. 0 - 1000 NTU measurement range. RS232 Output. ABS Housing.



 
Page: 1 | 2 | All