EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

Part# with Options:        CPS16D-7AT2C
Price with Options:        Please Email us your request for quote   

Options:    

Application Range
(1) Application Range for EH Memosens CPS16D
Shaft Length
(2) Shaft Length for EH Memosens CPS16D
Approval
(3) Approval for EH Memosens CPS16D

  Availability 4 Weeks  ]

Application
  • Long-term monitoring or limit control in processes with stable process conditions
    • Chemical processes
    • Pulp and paper industry
    • Power stations (e.g. flue gas cleaning)
    • Incinerator plants
    • Mining
    • Wastewater
  • Water treatment
    • Drinking water
    • Cooling water
    • Well water

With ATEX, IEC, FM and CSA approval for use in hazardous areas.

Your benefits
  • Simultaneous measurement of pH, ORP and rH value (in rH mode)
  • Additional electrode made of platinum, for measuring reference impedance
  • Low-maintenance and robust thanks to large PTFE ring junction
  • Can be used at pressures up to 17 bar (246 psi), absolute
  • Process glass also for very alkaline applications
  • Integrated temperature sensor for effective temperature compensation
  • Long service life thanks to poison-resistant reference with ion trap
  • Glass breakage and blockage detection by measuring:
    • Resistance of glass membrane
    • Reference impedance
Other advantages of Memosens technology
  • Maximum process safety owing to non-contact, inductive signal transmission
  • Data security thanks to digital data transmission
  • Very easy to use as sensor data saved in the sensor
  • Predictive maintenance possible as sensor load data logged in the sensor
Measuring principle pH measurement

The pH value is used as a unit of measurement for the acidity or alkalinity of a liquid medium. The membrane glass of the electrode supplies an electrochemical potential which is dependent upon the pH value of the medium. This potential is generated by the selective penetration of H + ions through the outer layer of the membrane. An electrochemical boundary layer with an electric potential forms at this point. An integrated Ag/AgCl reference system serves as the required reference electrode. The transmitter converts the measured voltage into the corresponding pH value using the Nernst equation.

ORP measurement

The ORP potential is a unit of measurement for the state of equilibria between oxidizing and reducing components of a medium. The ORP is measured using a platinum or gold electrode instead of the pH-sensitive glass membrane. Analog to the pH measurement, an integrated Ag/AgCl reference system is used as a reference electrode.

rH measurement

The rH value is defined as the negative logarithm of partial pressure of hydrogen in a solution. The pH value and ORP value of a solution must be measured simultaneously to calculate the rH value. The value is calculated using the following equation:

rH = 2 . (mV/S) + 2 pH
pH = measured pH value
mV = measured ORP value in mV + 207 mV (Ag/AgCl system)
S = slope of pH electrode

The rH value is an indicator of the oxidation or reducing ability of a process solution. The measuring range is from 0 to 42. A process medium with rH values between 0 and 9 has a high reducing ability; a low reducing ability with rH 9-17; an indeterminate ability with rH 17-25; a low oxidation ability with rH 25-34, and a high oxidation ability with rH 34-42.

Measuring Principle Glass electrode
Application Standard applications in process and environment. Long-term monitoring, processes with little change.
Characteristic Very robust with ion trap and dirt repellent PTFE diaphragm.
Measuring principle Gel compact electrode with PTFE ring-diaphragm with ion trap. Pt-disc as additional ORP element. rH measurment and control of the reference impedance.
Design - all shaft lengths with temperature sensor, advanced gel technology - digital electrode with Memosens technology
Material Glass / PTFE
Dimension Durchmesser : 12mmSchaftlängen : 120, 225, 360 und 425mm
Process temperature max. 135°C (274°F)
Process pressure max. 16 bar (230 psi)
temperature sensor NTC 30k
Connection Inductive, digital connection head with Memosens technology.
Ingres protection IP68


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> PH & ORP ELECTRODES > HAZARDOUS LOCATIONS :    20 Items found.
CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

CLS16-3C1A1P
(298)

ENDRESS+HAUSER  CLS16-3C1A1P

EH Condumax CLS16D 2-electrode Analog conductive conductivity sensor for hygienic applications. DN50 Process Connection. IP68. ATEX Approval.

CLS15D-A1A1
(271)

ENDRESS+HAUSER  CLS15D-A1A1

EH Condumax CLS15D 2-electrode Digital conductive conductivity sensor for applications in pure and ultrapure water. Memosens technology. 1/2"NPT or 3/4" NPT Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS50-A1B1
(303)

ENDRESS+HAUSER  CLS50-A1B1

EH Indumax CLS50 Analog toroidal conductivity sensor for standard, hazardous and high-temperature chemistry applications. Inductive cell. PEEK or PFA material. Integrated Pt100 temperature sensor. IP67. ATEX, FM and CSA approvals.

CLS21-C1E4A
(297)

ENDRESS+HAUSER  CLS21-C1E4A

EH Condumax CLS21 2-electrode Analog conductive conductivity sensor for medium and high measuring ranges. NPT 1" or G1 Process Connection. IP65/67. ATEX Approval.

CLS54-AMV5012
(302)

ENDRESS+HAUSER  CLS54-AMV5012

EH Indumax CLS54 Analog toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. DN40 to DN125 Process Connection. Integrated Pt1000 temperature sensor. 100 µS/cm - 2000 mS/cm Measurement range. IP68. ATEX, FM and CSA Approvals.

CLS52-A1MV1A1
(168)

ENDRESS+HAUSER  CLS52-A1MV1A1

EH Indumax CLS52 analog toroidal conductivity sensor for hygienic and sterile applications. Stainless steel Pt100 temperature sensor. Inductive measuring cell. 0 - 2000 mS/cm measuring range. IP67. ATEX and qualitity certifications.

CLS50D-AA1B11
(188)

ENDRESS+HAUSER  CLS50D-AA1B11

EH Indumax CLS50D Digital Memosens toroidal inductive conductivity sensor for hazardous and high-temperature chemistry applications. Corrosion and moisture resistant. PEEK or PFA material. Integrated Pt1000 temperature sensor. IP67. ATEX, CSA, FM and IECEx approvals.

CLS16D-3C1P1
(296)

ENDRESS+HAUSER  CLS16D-3C1P1

EH Condumax CLS16D 2-electrode Digital conductive conductivity sensor for hygienic applications. Memosens technology. DN50 Process Connection. IP68. ATEX, FM and CSA Approvals.

COS51D-AS800
(179)

ENDRESS+HAUSER  COS51D-AS800

EH Oxymax COS51D digital memosens amperometric sensor for the measurment of Oxygen (O2) in water, wastewater and utilities applications. Corrosion and moisture resistant. 0 to 2000 hPa measuring range. Thread NPT 3/4 Head. POM sensor body and membrane cap.

CLS21D-C1E1
(295)

ENDRESS+HAUSER  CLS21D-C1E1

EH Condumax CLS21D 2-electrode Digital conductive conductivity sensor for medium and high measuring ranges. Memosens technology. NPT 1" or G1 Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS30-D1C4A
(167)

ENDRESS+HAUSER  CLS30-D1C4A

EH Condumax W CLS30 2-electrode conductivity sensor for waste water and concentrate applications. Pt100 temperature sensor. 0,1-200,0mS/cm measuring range. 10ft cable connection. PP/PTFE Material. DN25 Process connection. IP65. ATEX and qualitity certifications.

COS22D-AA1A2B22
(178)

ENDRESS+HAUSER  COS22D-AA1A2B22

EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals.

OUSAF44-B0A0
(325)

ENDRESS+HAUSER  OUSAF44-B0A0

EH OUSAF44 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 254-365 nm wavelenght range. 0-2,5 AU measurement range. CIP, SIP, FM and ATEX approvals. IP65.

OUSAF22-B0C0A
(322)

ENDRESS+HAUSER  OUSAF22-B0C0A

EH OUSAF22 Optical sensor combined with OUA260 flow assembly for the measurement of color concentrations in liquids. 390-1100 nm wavelenght range. 0-2,5 AU measurement range. Embedded validation filter. FM and ATEX approvals.

OUSAF21-D0C0D1D1D1A1A
(321)

ENDRESS+HAUSER  OUSAF21-D0C0D1D1D1A1A

EH OUSAF21 Optical sensor for the measurement of low color concentrations in water. 390-1100 nm wavelength range. Embedded validation filter. Female NPT Process Connection. 0,75" nominal diameter. FM and ATEX approvals.

CPS341D-7A1B1
(292)

ENDRESS+HAUSER  CPS341D-7A1B1

EH Ceramax CPS341D Digital non-glass pH memosens electrode for hygienic applications. Corrosion, moisture resistant. 87psi max pressure. IP68. ATEX approval. 0-10pH; 0-140oC; 6 bar.