Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CLS50D-AA1B11 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Indumax CLS50D Digital Memosens toroidal inductive conductivity sensor for hazardous and high-temperature chemistry applications. Corrosion and moisture resistant. PEEK or PFA material. Integrated Pt1000 temperature sensor. IP67. ATEX, CSA, FM and IECEx approvals.

Part# with Options:        CLS50D-AA1B11
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH Memosens CLS50D
Process Connection
(2) Process Connection for EH Memosens CLS50D
Sensor, Seal & Adapter Material
(3) Sensor, Seal & Adapter Material for EH Indumax CLS50D
Cable Lenght
(4) Cable Lenght for EH Indumax CLS50D
Cable Connection
(5) Cable Connection for EH Memosens CLS50D

  Availability 2 Weeks  ]

Application

Indumax CLS50/CLS50D is particularly suitable for use in the chemical industry and process engineering. The six-decade measuring range and the excellent chemical resistance properties of the materials in contact with the medium (PFA or PE

  • Concentration measurement of acids and bases
  • Quality monitoring of chemical products in tanks and pipes
  • Phase separation of product/product mixtures

The CLS50D digital sensor is used with Liquiline CM44x or Liquiline M CM42, while the CLS50 analog sensor is used with the Liquiline M CM42, Liquisys CLM223/253 or Mycom CLM153 transmitters.

Your benefits
  • High durability
    • High chemical resistance thanks to PFA coating
    • PEEK version for temperatures up to 180 C (356 F)
  • Low risk of soiling
    • Dirt-repellent PFA surface
    • Large sensor opening
  • Easy installation
    • Can be installed in pipes ≥ DN 80
    • Total cable length up to 55 m (180 ft)
  • Large measuring range from 2 μS/cm to 2000 mS/cm
  • Integrated, coated Pt 100 temperature sensor, error class A
  • Ex approval Ex ia IIC T4/T6
Other advantages of Memosens technology
  • Maximum process safety
  • Data security thanks to digital data transmission
  • Very easy to use as sensor data saved in the sensor
  • Predictive maintenance possible as sensor load data logged in the sensor
Measuring principle

An oscillator (1) generates an alternating magnetic field in the primary coil (5), which induces a current flow (4) in the medium. The strength of the current depends on the conductivity and thus on the ion concentration in the medium. The current flow in the medium, in turn, generates a magnetic field in the secondary coil (3). The resulting induced current is measured by the receiver (2) and used to determine the conductivity.

Measuring Principle Inductive
Application Waste water, process
Characteristic Inductive conductivity cell made of highly resistant material for conductivity and concentration neasurements in process applications.
Measurement range 2S/cm - 2000 mS/cm
Measuring principle Inductive conductivity measurement
Design - No direct contact with the media because of the sensor coating made of highly resistant material.
Material PEEK or PFA
Dimension Electrode: outside diameter: appr. 47 mm inside diameter: appr. 15 mm
Process temperature max. 125C (PEEK)
(254F)max. 125C (PFA)
(254F)
Process pressure max. 20 bar (PEEK)
(290 psi) max. 16 bar (PFA)
(233 psi)
temperature sensor Integrated Pt1000
Connection Process connection: NPT1", DN50, AINSI, JIScable: fixed cable connection.
Ingres protection IP67
Additional Certifications Calibration certification of the cell constant.

  • CONDUCTIVITY ANALIZERS > ASSEMBLY
    CLA140-3A1A110 EH Dipfit CLA140 immersion assembly for conductivity sensors in applications with aggressive media. Includes flange connection and holder with bayonet lock. Thread G3/4 sensor connection. IP65...


  • CONDUCTIVITY ANALIZERS > ASSEMBLY
    CLA111-00A EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS :    20 Items found.
CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

CLS16-3C1A1P
(298)

ENDRESS+HAUSER  CLS16-3C1A1P

EH Condumax CLS16D 2-electrode Analog conductive conductivity sensor for hygienic applications. DN50 Process Connection. IP68. ATEX Approval.

CLS15D-A1A1
(271)

ENDRESS+HAUSER  CLS15D-A1A1

EH Condumax CLS15D 2-electrode Digital conductive conductivity sensor for applications in pure and ultrapure water. Memosens technology. 1/2"NPT or 3/4" NPT Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS50-A1B1
(303)

ENDRESS+HAUSER  CLS50-A1B1

EH Indumax CLS50 Analog toroidal conductivity sensor for standard, hazardous and high-temperature chemistry applications. Inductive cell. PEEK or PFA material. Integrated Pt100 temperature sensor. IP67. ATEX, FM and CSA approvals.

CLS21-C1E4A
(297)

ENDRESS+HAUSER  CLS21-C1E4A

EH Condumax CLS21 2-electrode Analog conductive conductivity sensor for medium and high measuring ranges. NPT 1" or G1 Process Connection. IP65/67. ATEX Approval.

CLS54-AMV5012
(302)

ENDRESS+HAUSER  CLS54-AMV5012

EH Indumax CLS54 Analog toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. DN40 to DN125 Process Connection. Integrated Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm Measurement range. IP68. ATEX, FM and CSA Approvals.

CLS52-A1MV1A1
(168)

ENDRESS+HAUSER  CLS52-A1MV1A1

EH Indumax CLS52 analog toroidal conductivity sensor for hygienic and sterile applications. Stainless steel Pt100 temperature sensor. Inductive measuring cell. 0 - 2000 mS/cm measuring range. IP67. ATEX and qualitity certifications.

CLS16D-3C1P1
(296)

ENDRESS+HAUSER  CLS16D-3C1P1

EH Condumax CLS16D 2-electrode Digital conductive conductivity sensor for hygienic applications. Memosens technology. DN50 Process Connection. IP68. ATEX, FM and CSA Approvals.

COS51D-AS800
(179)

ENDRESS+HAUSER  COS51D-AS800

EH Oxymax COS51D digital memosens amperometric sensor for the measurment of Oxygen (O2) in water, wastewater and utilities applications. Corrosion and moisture resistant. 0 to 2000 hPa measuring range. Thread NPT 3/4 Head. POM sensor body and membrane cap.

CLS21D-C1E1
(295)

ENDRESS+HAUSER  CLS21D-C1E1

EH Condumax CLS21D 2-electrode Digital conductive conductivity sensor for medium and high measuring ranges. Memosens technology. NPT 1" or G1 Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS30-D1C4A
(167)

ENDRESS+HAUSER  CLS30-D1C4A

EH Condumax W CLS30 2-electrode conductivity sensor for waste water and concentrate applications. Pt100 temperature sensor. 0,1-200,0mS/cm measuring range. 10ft cable connection. PP/PTFE Material. DN25 Process connection. IP65. ATEX and qualitity certifications.

COS22D-AA1A2B22
(178)

ENDRESS+HAUSER  COS22D-AA1A2B22

EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals.

OUSAF44-B0A0
(325)

ENDRESS+HAUSER  OUSAF44-B0A0

EH OUSAF44 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 254-365 nm wavelenght range. 0-2,5 AU measurement range. CIP, SIP, FM and ATEX approvals. IP65.

OUSAF22-B0C0A
(322)

ENDRESS+HAUSER  OUSAF22-B0C0A

EH OUSAF22 Optical sensor combined with OUA260 flow assembly for the measurement of color concentrations in liquids. 390-1100 nm wavelenght range. 0-2,5 AU measurement range. Embedded validation filter. FM and ATEX approvals.

OUSAF21-D0C0D1D1D1A1A
(321)

ENDRESS+HAUSER  OUSAF21-D0C0D1D1D1A1A

EH OUSAF21 Optical sensor for the measurement of low color concentrations in water. 390-1100 nm wavelength range. Embedded validation filter. Female NPT Process Connection. 0,75" nominal diameter. FM and ATEX approvals.

CPS341D-7A1B1
(292)

ENDRESS+HAUSER  CPS341D-7A1B1

EH Ceramax CPS341D Digital non-glass pH memosens electrode for hygienic applications. Corrosion, moisture resistant. 87psi max pressure. IP68. ATEX approval. 0-10pH; 0-140oC; 6 bar.