EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.
Measure Tube Material
A-Stainl. steel C-Stainl. steel, mat. certificate (wetted parts) P-Stainl. steel, PED Cat.III R-Stainl. steel, PED Cat.III, mat. certificate 9-Special version, TSP no. to be spec.
(1) Measure Tube Material for EH 83E
Process Connection
AAS-Cl.150, 316L/1.4404, flange ANSI B16.5 ABS-Cl.300, 316L/1.4404, flange ANSI B16.5 ACS-Cl.600, 316L/1.4404, flange ANSI B16.5 D2N-PN40, NAMUR NE132 insertion length 316L/1.4404,EN10921B1 D2S-PN40, 316L/1.4404, EN10921B1 (DIN2501) flange D3S-PN63, 316L/1.4404, EN10921B2 (DIN2501) flange D4S-PN100, 316L/1.4404, EN10921B2 (DIN2501) flange D6N-PN40 groove,NAMUR NE132 insertion length 316L/1.4404,EN10921D D6S-PN40 groove, 316L/1.4404, EN10921D (DIN2512N) flange D7S-PN63 groove, 316L/1.4404, EN10921D (DIN2512N) flange D8S-PN100 groove, 316L/1.4404, EN10921D (DIN2512N) flange FJA-ISO2853 thread, ISO2037, 0.8um/150grit 3A, 316L/1.4404 FJW-ISO2853 thread, ISO2037, 1.4404/316L FKA-DIN11864 2A flange, DIN11866, 0.8um/ 150grit , line A, flang FKW-DIN11864 2A flange, DIN11866 line A, flange with notch, 1.44 FLA-DIN11864 1A thread, 0.8um/150grit DIN11866 line A, 3A, 1.440 FLW-DIN11864 1A thread DIN11866 line A, 1.4404/316L FMA-DIN11851, thread, 3A, DIN11866 line A 0.8um/150grit, 1.4404/ FMW-DIN11851, thread, 1.4404/316L DIN11866 line A FSA-SMS1145, thread, 0.8um/150grit, 3A 1.4404/316L FSW-SMS1145, thread, 1.4404/316L NDS-10K, SUS316L, flange JIS B2220 NES-20K, SUS316L, flange JIS B2220 NGS-40K, SUS316L, flange JIS B2220 999-Special version, TSP no. to be spec.
(2) Process Connection for EH 83E
Additional Test & Certificate
A-Basic version B-pressure test (tube) C-Cleaned from oil+grease (wetted parts) D-Cleaned from oil+grease (wetted parts) + Pressure test (tube) E-EAC marking N-EAC marking + pressure test (tube) Q-Rupture disk + basic version R-Rupture disk + pressure test (tube) S-marine certificate T-marine certificate + pressure test (tube) 5-CRN approval 6-CRN approval + pressure test (tube) 7-Rupture disk + CRN aproval + pressure test ( tube) 9-Special version, TSP no. to be spec.
(3) Additional Test & Certificate for EH 83E
Calibration
A-0.15%, 0.0005g/cc C-0.15% 5pt, 0.0005g/cc G-0.15% 5pt, 0.0005g/cc, traceable ISO/IEC17025 P-0.1%, 0.0005g/cc 9-Special version, TSP no. to be spec.
(4) Calibration for EH 83E
Approval
A-Non hazardous area B-ATEX II 2GD+ IECEx Z1,21 Ex dia IIC Ex tD A21 Z= Zone D-ATEX II 2GD+ IECEx Z1,21 Ex deia IIC Ex tD A21 Z= Zone H-ATEX II 3G EEx n IIC K-NEPSI Ex dia IIC N-XP FM Cl.I Div.1/CSA Cl.I Div.1, ABCD + Zone 1 R-FM NI Cl.I Div.2/CSA Cl.I Div.2, ABCD + Zone 2 S-NEPSI Ex deia IIC U-TIIS Ex dia IIC 9-Special version, TSP no. to be spec.
(5) Approval for EH 83E
Housing
A-Compact IP67 NEMA4X, Aluminium C-Remote, wall IP67 NEMA4X + 10m/30ft cable D-Remote, Wall IP67 NEMA4X+ 20m/65ft cable E-Remote, field IP67 NEMA4X + 10m/30ft Cable F-Remote, field IP67 NEMA4X + 20m/65ft Cable 1-Compact IP67 NEMA4X, Alu, (40)oC/oF T amb. 3-Remote, wall IP67 NEMA4X,(40)oC/oF T amb. + 20m/65ft cable 4-Compact IP67 NEMA 4X, Alu, HE, (40)oC/oF T amb., HE = harsh env 6-Remote, wall IP67 NEMA4X, HE, (40)oC/oF T amb. + 20m/65 ft cabl 7-Remote,field IP67 NEMA4X,(40)oC/oF T amb. + 20m/65ft cable 8-Remote, field IP67 NEMA4X, HE, (40)oC/oF T amb. + 20m/65 ft cab 9-Special version, TSP no. to be spec.
(6) Housing for EH 83E
Cable Entry
A-Gland M20 (EEx d > thread M20) B-Thread NPT 1/2 C-Thread G 1/2 F-Gland G 1/2 Ex d Shimada, T4 K-Bus plug + gland M20 L-Bus plug + thread NPT 1/2 M-Bus plug + thread G 1/2 Q-2 x Bus plug + gland M20 R-2 x Bus plug + thread NPT 1/2 S-2 x Bus plug + thread G 1/2 X-Not used, sensor only 9-Special version, TSP no. to be spec.
(7) Cable Entry for EH 83E
Power Supply & Display
A-85 to 260VAC; WEA, 4 line + Touch control WEA B-20 to 55VAC / 16 to 62VDC; WEA, 4 line + Touch control, WEA C-85 to 260VAC; SEA, 4 line + Touch control SEA D-20 to 55VAC / 16 to 62VDC; SEA, 4 line + Touch control, SEA E-85 to 260VAC; EES, 4 line + Touch control EES F-20 to 55VAC / 16 to 62VDC; EES, 4 line + Touch control, EES G-85 to 260VAC; CN, 4 line + Touch control, CN H-20 to 55VAC / 16 to 62VDC; CN, 4 line + Touch control, CN P-HART 7; 85 to 260VAC; 4 line + Touch control Q-HART 7; 20 to 55VAC /16 to 62VDC; 4 line + Touch control R-HART 7; 85 to 260VAC; 4 line + Touch control S-HART 7; 20 to 55VAC /16 to 62VDC; 4 line + Touch control T-HART 7; 85 to 260VAC; 4 line + Touch control U-HART 7; 20 to 55VAC /16 to 62VDC; 4 line + Touch control 4-HART 7; 85 to 260VAC; 4 line + Touch control 5-HART 7; 20 to 55VAC /16 to 62VDC; 4 line + Touch control 7-85 to 260VAC; WEA, w/o display, Remote configuration, WEA 8-20 to 55VAC / 16 to 62VDC; WEA, w/o display, rem. configuration X-Sensor only 9-Special version, TSP no. to be spec.
(8) Power Supply & Display for EH 83E
Adjustment & Software Feature
A-Default liquid; Basic version B-Default gas; Basic version C-Default liquid; Concentration measurement D-Default gas; Advanced diagnostics E-Default liquid; Advanced diagnostics J-Default liquid; Batching K-Default gas; Batching L-Default liquid; Batching + Concentration measurement N-Default liquid; Batching + Advanced diagnostics R-Default liquid; Advanced diagnostics + Concentration measureme T-Default liquid; Batching + Diagnostics+ Concentration measurem X-Sensor only 9-Special version, TSP no. to be spec.
(9) Adjustment & Software Feature for EH 83E
Output & Input
A-4 to 20mA SIL HART + frequency B-4 to 20mA SIL HART + freq. + 2x relay C-4 to 20mA SIL HART + freq. + 2x relay M= modules exchangeable D-4 to 20mA SIL HART + freq.+ relay+stat.In modules exchangeable E-4 to 20mA SIL HART + 20mA+ relay+stat.In modules exchangeable F-PROFIBUS PA, Ex i G-FOUNDATION Fieldbus, Ex i H-PROFIBUS PA I-EtherNet/IP J-PROFIBUS DP K-FOUNDATION Fieldbus L-4 to 20mA SIL HART + 2x relay + stat.In modules exchangeable M-4 to 20mA SIL HART + 2x freq. + stat.In modules exchangeable N-Modbus RS485 + 20mA +freq.+stat.In modules exchangeable P-PROFIBUS DP + 20mA + freq.+ stat.In modules exchangeable Q-Modbus RS485 + stat.In R-4 to 20mA SIL HART + 0/4 to 20mA, active Ex i S-4 to 20mA SIL HART active + freq., Ex i, freq. = passive T-4 to 20mA SIL HART passive + freq., Ex i, freq. = passive U-4 to 20mA SIL HART + 0/4 to 20mA, passive Ex i V-PROFIBUS DP + 2x relay + stat.In modules exchangeable W-4 to 20mA SIL HART + 2x 20mA + relay modules exchangeable X-Sensor only 0-4 to 20mA SIL HART + 2x 20mA + stat.In modules exchangeable 9-Special version, TSP no. to be spec.
(10) Output & Input for EH 83E