InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(194) Be the First to Review this Item

ENDRESS+HAUSER  FMR54-AAAAAAAAA8CGJ

LEVEL / RADAR TRANSMITTERS
FM-CSA


 Information Request
 Shipping Rates
 Volume discount
      



ENDRESS+HAUSER FMR54-AAAAAAAAA8CGJ (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Micropilot FMR54 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids (strong steam, ammonia). High temperature and high pressure applications. DN80 to DN300 Process Connection. 2-wire or 4-wire HART communication. 316L Main wetted parts. FM and CSA approvals.

Part# with Options:        FMR54-AAAAAAAAA8CGJ
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMR50 & FMR54
Power Supply
(2) Power Supply for EH FMR50/52/54/56
Display & Operation
(3) Display & Operation for EH FMR50/52/54/56
Housing
(4) Housing for EH FMR52/54/57
Electrical Connection
(5) Electrical Connection for EH FMR50/52/54/56
Antenna
(6) Antenna for EH FMR54
Seal
(7) Seal for EH FMR54
Process Connection
(8) Process Connection for EH FMR54

  Availability 10 Days  ]

Application
  • Continuous, non-contact level measurement of liquids, pastes and slurries
  • Rod antenna (FMR53); horn or planar antenna (FMR54)
  • Maximum measuring range: 20 m (66 ft); for FMR54 with planar antenna in stilling well: 38 m (125 ft)
  • Temperature: 196 to +400 C (321 to +752 F)
  • Pressure: 1 to +160 bar (14.5 to +2 320 psi)
  • Accuracy: 6 mm
  • International explosion protection certificates; WHG; marine approvals
  • Linearity protocol (3-point, 5-point)
Your benefits
  • Reliable measurement even for changing product and process conditions
  • HistoROM data management for easy commissioning, maintenance and diagnostics
  • Highest reliability due to Multi-Echo Tracking
  • SIL2 according to IEC 61508, SIL3 in case of homogeneous or heterogeneous redundancy
  • Seamless integration into control or asset management systems
  • Intuitive user interface in national languages
  • Easy proof test for SIL and WHG
Measuring principle

The Micropilot is a "downward-looking" measuring system, operating based on the time-of-flight method (ToF). It measures the distance from the reference point (process connection) to the product surface. Radar impulses are emitted by an antenna, reflected off the product surface and received again by the radar system.

Measuring Principle Level radar
Characteristic / Application Continuous non contact level measurement for use in high-pressure and high-temperature applications,
Horn or planar antenna
Specialities SIL 2 according to IEC 61508,
Safety and reliability with Multi-Echo Tracking
HistoROM
Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Frequency C-band (~6 GHz)
Accuracy +/- 6 mm (0.24 in)
Ambient temperature -40...+80 C
(-40...+176 F)
Process temperature -60...+400C
(-76...+752F)
Process pressure absolute / max. overpressure limit Vacuum...160 bar
(Vacuum...2320 psi)
Main wetted parts 316L
Process connection Flange:
DN80...DN300,
ASME 3"...12",
JIS 10K, 20K
Max. measurement distance 20 m (65 ft)
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, KC
Safety approvals Overfill prevention WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000
Marine approval GL/ ABS/ LR/ BV/ DNV
Options Display,
Customized parameterization
PWIS free
Gastight feed through
Application limits Maximum measuring range is dependent on the tank form and/or application
Free space with nozzle FMR51, FMR52, FMR53
Stilling well with ball valve:
FMR51, FMR52
Hygiene requirements:
FMR52, FMR53
316L or Alloy C non-resistant:
FMR52, FMR53


B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> RADAR TRANSMITTERS > FM-CSA :    11 Items found.
FMP50-AAAAAAAAA1GDJ (201) ENDRESS+HAUSER  FMP50-AAAAAAAAA1GDJ

EH Levelflex FMP50 Guided Time-of-Flight Radar for level measurement in liquids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 316L, PPS or Viton main wetted parts. IP66/68 NEMA4X/6P. FM and CSA approvals.

  

 

 
FMP56-AAAAAALBABGDE (206) ENDRESS+HAUSER  FMP56-AAAAAALBABGDE

EH Levelflex FMP56 Guided Time-of-Flight Radar for continuos level measurement in bulk solids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

  

 

 
FMP51-AAAAAAABA4GDJ (202) ENDRESS+HAUSER  FMP51-AAAAAAABA4GDJ

EH Levelflex FMP51 Guided Time-of-Flight Radar for level measurement for highest demands in liquids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 316, 316L, Alloy C, Ceramic or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

  

 

 
FMR50-AAAAAABMGGF (190) ENDRESS+HAUSER  FMR50-AAAAAABMGGF

EH Micropilot FMR50 Time-of-Flight Radar for continuos level measurement in liquids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. Encapsulated PVDF or PP clad horn antenna. FM and CSA approvals.

  

 

 
FMR56-AAAAAABNXR0 (195) ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

  

 

 
FMP57-AAAAAAAFA4GGE (207) ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

  

 

 
FMP52-AAAAAACBTJK (203) ENDRESS+HAUSER  FMP52-AAAAAACBTJK

EH Levelflex FMP52 Guided Time-of-Flight Radar for level measurement with coated probe in aggressive liquids. DN50 to DN100 Process Connection. 2-wire or 4-wire HART communication. 304, 304L, 316, 316L, PTFE or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

  

 

 
FMR57-AAAAAABCA6RGJ1 (196) ENDRESS+HAUSER  FMR57-AAAAAABCA6RGJ1

EH Micropilot FMR57 Time-of-Flight Radar for continuous non-contact level measurement in bulk solids (highest demands). DN80 to DN100 Process Connection. 2-wire or 4-wire HART communication. 316L, PEEK, PTFE, Polyamid Main wetted parts. FM and CSA approvals.

  

 

 
FMR52-AAAAAABOCFK (193) ENDRESS+HAUSER  FMR52-AAAAAABOCFK

EH Micropilot FMR52 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids. DN50 to DN150 Process Connection. 2-wire or 4-wire HART communication. PTFE-filled and flush-mounted horn antenna. FM and CSA approvals.

  

 

 
FMP54-AAAAAAAFD1GIJ (204) ENDRESS+HAUSER  FMP54-AAAAAAAFD1GIJ

EH Levelflex FMP54 Guided Time-of-Flight Radar for continuos level measurement on high temperature and high pressure applications. DN50 to DN100 Process Connection with ceramic-graphite seal. 2-wire or 4-wire HART communication. 304, 316, 316L, Alloy C or Ceramic main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

  

 

 
FMP55-AAAAAACBCQK (205) ENDRESS+HAUSER  FMP55-AAAAAACBCQK

EH Levelflex FMP55 Multiparameter Time-of-Flight Radar with SensorFusion for level measurement in liquids with capacitance and guided principles. DN50 to DN150 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316L, PTFEor PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
FMR54-AAAAAAAAA8CG

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site