Process Control Instruments, Field Devices and Industrial Automation
SKU# (196)

ENDRESS+HAUSER  FMR57-AAAAAABCA6RGJ1




ENDRESS+HAUSER FMR57-AAAAAABCA6RGJ1 (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Micropilot FMR57 Time-of-Flight Radar for continuous non-contact level measurement in bulk solids (highest demands). DN80 to DN100 Process Connection. 2-wire or 4-wire HART communication. 316L, PEEK, PTFE, Polyamid Main wetted parts. FM and CSA approvals.

Part# with Options:        FMR57-AAAAAABCA6RGJ1
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMR57
Power Supply
(2) Power Supply for EH FMR50/52/54/56
Display & Operation
(3) Display & Operation for EH FMR50/52/54/56
Housing
(4) Housing for EH FMR52/54/57
Electrical Connection
(5) Electrical Connection for EH FMR50/52/54/56
Antenna
(6) Antenna for EH FMR57
Seal
(7) Seal for EH FMR57
Process Connection
(8) Process Connection for EH FMR57
Air Purge Connection
(9) Air Purge Connection for EH FMR57

  Availability 5 Days  ]

Application
  • Continuous, non-contact level measurement in powdery to granular bulk solids
  • PP-cladded horn antenna (FMR56); horn or parabolic antenna (FMR57)
  • Maximum measuring range: 70 m (230 ft)
  • Temperature: 40 to +400 C (40 to 752 F)
  • Pressure: 1 to +16 bar (14.5 to +232 psi)
  • Accuracy: 3 mm
  • International explosion protection certificates
  • Linearity protocol (3-point, 5-point)
Your benefits
  • Reliable measurement even for changing product and process conditions
  • HistoROM data management for easy commissioning, maintenance and diagnostics
  • Highest reliability due to Multi-Echo Tracking
  • SIL2 according to IEC 61508, SIL3 in case of homogeneous or heterogeneous redundancy
  • Seamless integration into control or asset management systems
  • Intuitive user interface in national languages
  • Easy proof test for SIL
  • Heartbeat TechnologyTM
Measuring principle

The Micropilot is a "downward-looking" measuring system, operating based on the time-of-flight method (ToF). It measures the distance from the reference point (process connection) to the product surface. Radar impulses are emitted by an antenna, reflected off the product surface and received again by the radar system.

Measuring Principle Level radar solid
Characteristic / Application For highest demands in measuring tasks of bulk solids:
Reliable, non-contact level measurement in high silos, bunkers or stockpiles also under extreme conditions like strongly dusting and buildup-forming media
Specialities Safety and reliability with Multi-Echo Tracking
Air purge connection
HistoROM
Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Frequency K-band (~26 GHz)
Antenna Parabolic DN200/8", DN250/10"
Horn DN80/3", DN100/4"
Accuracy +/- 3 mm (0.12 in)
Ambient temperature -40...+80 C
(-40...+176 F)
Process temperature -40...+400 C
(-40...+752 F)
Process pressure absolute / max. overpressure limit Vacuum...16 bar
(Vacuum...232 psi)
Main wetted parts 316L, PEEK, PTFE, Polyamid
Process connection Thread:
MNPT 1 1/2, R 1 1/2
Flange:
DN80...DN100,
ASME 3"...4",
JIS 10K,
UNI DN100/8"...DN250/10"
Max. measurement distance 70 m (230 ft)
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, KC
Safety approvals SIL
Design approvals EN 10204-3.1
Marine approval GL/ ABS/ LR/ BV/ DNV
Options Display,
Customized parameterization
Antenna extension
PWIS free
Application limits Dk < 1.6
Reduction of the max. possible measuring range through:
Media with poor reflection properties
Angle of repose
Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling
Build-up, above all of moist products


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> RADAR TRANSMITTERS > FM-CSA :    25 Items found.
FTI55-AAK1RG1W2A1A
(225)

ENDRESS+HAUSER  FTI55-AAK1RG1W2A1A

EH Solicap FTI55 Capacitive Point Level Rod Probe for bulk solids. NPT 1 1/2 Process Connection. PE, PPS, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI56-AAM1RG1W2A1A
(230)

ENDRESS+HAUSER  FTI56-AAM1RG1W2A1A

EH Liquicap FTI56 Capacitive Point Level Rope Probe for bulk solids. R/NPT 1 1/2 Process Connection. PTFE, PA, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI51-AAH1GCJW2A1A
(224)

ENDRESS+HAUSER  FTI51-AAH1GCJW2A1A

EH Liquicap FTI51 Capacitive Point Level Rod Probe for highly viscous liquids. G/NPT 1/2 to G/NPT 1 1/2 Process Connection. PTFE, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FTI52-AAC1GDJW2A1A
(228)

ENDRESS+HAUSER  FTI52-AAC1GDJW2A1A

EH Liquicap FTI52 Capacitive Point Level Rope Probe for highly viscous liquids. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. FEP, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FMI52-A1CGDJV2A1A
(229)

ENDRESS+HAUSER  FMI52-A1CGDJV2A1A

EH Liquicap FMI52 Capacitive Rod Probe for continuous level measurement in liquids (large ranges). HART communication. FEP, PFA or 316L main wetted parts. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. IP66/67. FM and CSA approvals.

FMI51-A1HGCJV2A1A
(223)

ENDRESS+HAUSER  FMI51-A1HGCJV2A1A

EH Liquicap FMI51 Capacitive Rod Probe for continuous level measurement in liquids (extremely high temperatures). HART communication. PFA or 316L main wetted parts. DN50 to D100 Process Connection. IP66. FM and CSA approvals.

FMU40-ANB1A2
(217)

ENDRESS+HAUSER  FMU40-ANB1A2

EH Prosonic FMU40 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 16ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. G/NPT 1 1/2" Process Connection. FM and CSA approvals.

FMP50-AAAAAAAAA1GDJ
(201)

ENDRESS+HAUSER  FMP50-AAAAAAAAA1GDJ

EH Levelflex FMP50 Guided Time-of-Flight Radar for level measurement in liquids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 316L, PPS or Viton main wetted parts. IP66/68 NEMA4X/6P. FM and CSA approvals.

FTI77-A1AVVRG1W2A1A
(227)

ENDRESS+HAUSER  FTI77-A1AVVRG1W2A1A

EH Solicap FTI77 Capacitive Point Level Rod Probe for bulk solids in high temperatures. R 1 1/2 or NPT 1 1/2 Process Connection. Ceramic, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FMU42-AMB1A22A
(218)

ENDRESS+HAUSER  FMU42-AMB1A22A

EH Prosonic FMU42 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 33ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN80 or DN100 Process Connection. FM and CSA approvals.

FMP56-AAAAAALBABGDE
(206)

ENDRESS+HAUSER  FMP56-AAAAAALBABGDE

EH Levelflex FMP56 Guided Time-of-Flight Radar for continuos level measurement in bulk solids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMP51-AAAAAAABA4GDJ
(202)

ENDRESS+HAUSER  FMP51-AAAAAAABA4GDJ

EH Levelflex FMP51 Guided Time-of-Flight Radar for level measurement for highest demands in liquids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 316, 316L, Alloy C, Ceramic or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR50-AAAAAABMGGF
(190)

ENDRESS+HAUSER  FMR50-AAAAAABMGGF

EH Micropilot FMR50 Time-of-Flight Radar for continuos level measurement in liquids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. Encapsulated PVDF or PP clad horn antenna. FM and CSA approvals.

FMU44-AMB1A22A
(220)

ENDRESS+HAUSER  FMU44-AMB1A22A

EH Prosonic FMU44 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 66ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN100 to DN200 Process Connection. FM and CSA approvals.

FMR56-AAAAAABNXR0
(195)

ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

FMP57-AAAAAAAFA4GGE
(207)

ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FTL80-AASAABA1AAJVBJ
(240)

ENDRESS+HAUSER  FTL80-AASAABA1AAJVBJ

EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CSA approvals.

FTL81-AASAABA1ABJVBJ
(245)

ENDRESS+HAUSER  FTL81-AASAABA1ABJVBJ

EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals.

FMP52-AAAAAACBTJK
(203)

ENDRESS+HAUSER  FMP52-AAAAAACBTJK

EH Levelflex FMP52 Guided Time-of-Flight Radar for level measurement with coated probe in aggressive liquids. DN50 to DN100 Process Connection. 2-wire or 4-wire HART communication. 304, 304L, 316, 316L, PTFE or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR52-AAAAAABOCFK
(193)

ENDRESS+HAUSER  FMR52-AAAAAABOCFK

EH Micropilot FMR52 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids. DN50 to DN150 Process Connection. 2-wire or 4-wire HART communication. PTFE-filled and flush-mounted horn antenna. FM and CSA approvals.

Page: 1 | 2 | All