Process Control Instruments, Field Devices and Industrial Automation
SKU# (199)

ENDRESS+HAUSER  FMR533-AAXXJAC2RA




ENDRESS+HAUSER FMR533-AAXXJAC2RA (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Micropilot FMR533 Radar for high precision level measurement in custody transfer (up to 40m). DN150 to DN250 Process Connection. 4-wire HART communication. 450mm/20" Parabolic Antenna. 316L + PTFE main wetted parts. T12 Alu Housing IP65/68. ATEX, IECEx, FM and CSA approvals.

Part# with Options:        FMR533-AAXXJAC2RA
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMR530/533
Process Connection
(2) Process Connection for EH FMR533
Cable Entry
(3) Cable Entry for EH FMR530/532/533
Weight & Measure Approval
(4) Weight & Measure Approval for EH FMR530/532/533

  Availability 3 Weeks  ]

Application

The Micropilot S is used for highly accurate level measurement in storage tanks and can be applied in custody transfer applications. It meets the relevant requirements according to OIML R85 and API 3.1B

The FMR533 with parabolic antenna is excellently suited for free space applications up to 40 m (131 ft).

Your benefits
  • 0.5 mm (0.02 in) accuracy (2 value)
  • National approvals (NMi, PTB) for custody transfer.
  • Easy integration into tank gauging systems via the Tank Side Monitor NRF590.
  • Easy and safe local operation via menu-guided alphanumeric display.
  • Easy commissioning, documentation and maintenance via FDT/DTM technology (FieldCare).
  • Low-cost, easy installation via 4-wire cable with HART and 24 V DC (intrinsically safe).
  • Gas-tight process connection (second line of defense) standard for any antenna version.
  • Inventory Control version with reduced accuracy (3 mm [0.12 in]) available for all device versions.
Measuring principle

The Micropilot is a "downward-looking" measuring system, operating based on the time-of-flight method. It measures the distance from the reference point (process connection) to the product surface. Radar impulses are emitted by an antenna, reflected off the product surface and received again by the radar system.

Measuring Principle Level radar
Characteristic / Application Ideal for high precision measurement in storage tanks
Supply / Communication 4-wire (HART)
Frequency C-band (~6 GHz)
Accuracy +/- 1 mm, custody transfer
Ambient temperature Standard:
-40 C ... 80 C
(-40 F ... 176 F)
For calibration to regulatory standards:
-25 C ... 60 C
(-13 F ... 131 F)
Process temperature -40 C ... 200 C
(-40 F ... 392 F)
Process pressure absolute / max. overpressure limit Vacuum ... 16 bar
(Vacuum ... 232 psi)
Main wetted parts 316L + PTFE
Process connection DN150 ... DN250 / 6" ... 10"
Max. measurement distance 40 m (131 ft)
Communication 4 ... 20 mA HART
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI
Safety approvals Overfill prevention WHG
Application limits Maximum measuring range is dependent on the tank form and/or application

Free space and many baffles
FMR540


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> RADAR TRANSMITTERS > HAZARDOUS LOCATIONS :    47 Items found.
FTW31-A1A2EA0A
(264)

ENDRESS+HAUSER  FTW31-A1A2EA0A

EH Liquipoint FTW31 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTL325N-O1A1
(250)

ENDRESS+HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

FTW325-A2A1A
(266)

ENDRESS+HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

FMI21-A1D1A1
(233)

ENDRESS+HAUSER  FMI21-A1D1A1

EH Liquicap FMI21 Capacitive rod probe for continuos level measurement in conductive liquids. 316L, 1.4404 or PP wetted parts. NPT 1 1/2 or G 1 1/2 Process Connection. ATEX and CSA Approvals.

FTC262-AA32B1
(232)

ENDRESS+HAUSER  FTC262-AA32B1

EH Minicap FTC262 Capacitive rope probe for point level detection in light bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1 1/2 or R 1 1/2 Process Connection. PNP transistor and relay outputs. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

11375Z-RXG1A5A5
(257)

ENDRESS+HAUSER  11375Z-RXG1A5A5

EH 11375Z One rod probe for point level detection of conductive liquids with higher temperatures. 316Ti Rod. PTFE Partial Insulaion. G 1/2 Process Connection. Relay Communication. ATEX Approval.

11362Z-R1AA4A11CA
(259)

ENDRESS+HAUSER  11362Z-R1AA4A11CA

EH 11362Z Double rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FDU90-RG1AA
(211)

ENDRESS+HAUSER  FDU90-RG1AA

EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTC325-A2A31
(231)

ENDRESS+HAUSER  FTC325-A2A31

EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

FTM20-AA22A
(254)

ENDRESS+HAUSER  FTM20-AA22A

EH Soliphant FTM20 Vibronic Compact Point level limit switch for bulk solids in dust or hazardous areas. 1 1/4" NPT, 1 1/2" NPT or R Process Connection. ATEX, FM, CSA and IECEx approvals.

FDU91-RG1AA
(212)

ENDRESS+HAUSER  FDU91-RG1AA

EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTL50-AGE2AA1E4A
(237)

ENDRESS+HAUSER  FTL50-AGE2AA1E4A

EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11961Z-RCG1AB5
(256)

ENDRESS+HAUSER  11961Z-RCG1AB5

EH 11961Z One rod probe for point level detection of conductive liquids steam boilers. Highly resistant. 316Ti Rod. G 1/2 Process Connection. Relay Communication. ATEX Approval.

FTL51-AGE2DB1E4A
(241)

ENDRESS+HAUSER  FTL51-AGE2DB1E4A

EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11363Z-R1AA4A111CA
(260)

ENDRESS+HAUSER  11363Z-R1AA4A111CA

EH 11363Z Triple rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FTM21-AM622A
(255)

ENDRESS+HAUSER  FTM21-AM622A

EH Soliphant FTM21 Vibronic Compact Point level limit switch with extension tube for bulk solids in dust or hazardous areas. Stainless Steel Housing (316L). 1 1/4" NPT or 1 1/2" NPT Process Connection. ATEX, FM, CSA and IECEx approvals.

FTL325P-O1A1
(248)

ENDRESS+HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.

Page: 1 | 2 | 3 | All