Process Control Instruments, Field Devices and Industrial Automation
SKU# (217)

ENDRESS+HAUSER  FMU40-ANB1A2




ENDRESS+HAUSER FMU40-ANB1A2 (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Prosonic FMU40 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 16ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. G/NPT 1 1/2" Process Connection. FM and CSA approvals.

Part# with Options:        FMU40-ANB1A2
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMU40/42
Process Connection
(2) Process Connection for EH FMU40
Power Supply
(3) Power Supply for EH FMU40/41/42/44
Operation
(4) Operation for EH FMU4X
Housing
(5) Housing for EH FMU40/41/42/44
Cable Entry
(6) Cable Entry for EH FMU41X

  Availability 2 Weeks  ]

Application
  • Continuous, non-contact level measurement in fluids, pastes, sullages and coarse bulk materials
  • Flow measurement in open channels and measuring weirs
  • System integration via:
    • HART (standard), 4 to 20mA
    • PROFIBUS PA
    • FOUNDATION Fieldbus
  • Maximum measuring range:
    • FMU40: 5 m (16 ft) in fluids, 2 m (6.6 ft) in bulk materials
    • FMU41: 8 m (26 ft) in fluids, 3,5 m (11 ft) in bulk materials
    • FMU42: 10 m (33 ft) in fluids, 5 m (16 ft) in bulk materials
    • FMU43: 15 m (49 ft) in fluids, 7 m (23 ft) in bulk materials
    • FMU44: 20 m (66 ft) in fluids, 10 m (33 ft) in bulk materials
Features and benefits
  • Quick and simple commissioning via menu-guided on-site operation with four-line, multilingual plain text display
  • Envelope curves on the on-site display for simple diagnosis
  • Easy remote operation, diagnosis and measuring point documentation with the free operating program FieldCare supplied.
  • Suitable for explosion hazardous areas (Gas-Ex, Dust-Ex)
  • Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
  • Non-contact measurement method minimizes service requirements
  • Optional remote display and operation (up to 20 m (66 ft) from transmitter)
  • Installation possible from thread G 11⁄2 or 11⁄2 NPT upwards
  • Integrated temperature sensor for automatic correction of the temperature dependent sound velocity

Measuring Principle Ultrasonic
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus
Accuracy +/- 2 mm or +/- 0.2 % of set measuring range
Ambient temperature -40 C ... 80 C
(-40 F ... 176 F)
Process temperature -40 C ... 80 C
(-40 F ... 176 F)
Process pressure absolute / max. overpressure limit 0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Main wetted parts PVDF
Process connection G / NPT 1 1/2"
Blocking distance 0.25 m (0.8 ft)
Max. measurement distance 5 m (16 ft)
Communication 4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, TIIS, INMETRO, NEPSI
Application limits For higher resistance:
FMU42/FDU9x
Foam / high turbulence possible:
FMU41/FDU91
Fast filling and discharging rate:
FMU90 + FDU9x
Level limit detection:
FMU90 + FDU9x


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ULTRASONIC TRANSMITTERS > FM-CSA :    25 Items found.
FTI55-AAK1RG1W2A1A
(225)

ENDRESS+HAUSER  FTI55-AAK1RG1W2A1A

EH Solicap FTI55 Capacitive Point Level Rod Probe for bulk solids. NPT 1 1/2 Process Connection. PE, PPS, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI56-AAM1RG1W2A1A
(230)

ENDRESS+HAUSER  FTI56-AAM1RG1W2A1A

EH Liquicap FTI56 Capacitive Point Level Rope Probe for bulk solids. R/NPT 1 1/2 Process Connection. PTFE, PA, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI51-AAH1GCJW2A1A
(224)

ENDRESS+HAUSER  FTI51-AAH1GCJW2A1A

EH Liquicap FTI51 Capacitive Point Level Rod Probe for highly viscous liquids. G/NPT 1/2 to G/NPT 1 1/2 Process Connection. PTFE, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FTI52-AAC1GDJW2A1A
(228)

ENDRESS+HAUSER  FTI52-AAC1GDJW2A1A

EH Liquicap FTI52 Capacitive Point Level Rope Probe for highly viscous liquids. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. FEP, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FMI52-A1CGDJV2A1A
(229)

ENDRESS+HAUSER  FMI52-A1CGDJV2A1A

EH Liquicap FMI52 Capacitive Rod Probe for continuous level measurement in liquids (large ranges). HART communication. FEP, PFA or 316L main wetted parts. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. IP66/67. FM and CSA approvals.

FMI51-A1HGCJV2A1A
(223)

ENDRESS+HAUSER  FMI51-A1HGCJV2A1A

EH Liquicap FMI51 Capacitive Rod Probe for continuous level measurement in liquids (extremely high temperatures). HART communication. PFA or 316L main wetted parts. DN50 to D100 Process Connection. IP66. FM and CSA approvals.

FMP50-AAAAAAAAA1GDJ
(201)

ENDRESS+HAUSER  FMP50-AAAAAAAAA1GDJ

EH Levelflex FMP50 Guided Time-of-Flight Radar for level measurement in liquids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 316L, PPS or Viton main wetted parts. IP66/68 NEMA4X/6P. FM and CSA approvals.

FTI77-A1AVVRG1W2A1A
(227)

ENDRESS+HAUSER  FTI77-A1AVVRG1W2A1A

EH Solicap FTI77 Capacitive Point Level Rod Probe for bulk solids in high temperatures. R 1 1/2 or NPT 1 1/2 Process Connection. Ceramic, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FMU42-AMB1A22A
(218)

ENDRESS+HAUSER  FMU42-AMB1A22A

EH Prosonic FMU42 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 33ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN80 or DN100 Process Connection. FM and CSA approvals.

FMP56-AAAAAALBABGDE
(206)

ENDRESS+HAUSER  FMP56-AAAAAALBABGDE

EH Levelflex FMP56 Guided Time-of-Flight Radar for continuos level measurement in bulk solids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMP51-AAAAAAABA4GDJ
(202)

ENDRESS+HAUSER  FMP51-AAAAAAABA4GDJ

EH Levelflex FMP51 Guided Time-of-Flight Radar for level measurement for highest demands in liquids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 316, 316L, Alloy C, Ceramic or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR50-AAAAAABMGGF
(190)

ENDRESS+HAUSER  FMR50-AAAAAABMGGF

EH Micropilot FMR50 Time-of-Flight Radar for continuos level measurement in liquids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. Encapsulated PVDF or PP clad horn antenna. FM and CSA approvals.

FMU44-AMB1A22A
(220)

ENDRESS+HAUSER  FMU44-AMB1A22A

EH Prosonic FMU44 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 66ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN100 to DN200 Process Connection. FM and CSA approvals.

FMR56-AAAAAABNXR0
(195)

ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

FMP57-AAAAAAAFA4GGE
(207)

ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FTL80-AASAABA1AAJVBJ
(240)

ENDRESS+HAUSER  FTL80-AASAABA1AAJVBJ

EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CSA approvals.

FTL81-AASAABA1ABJVBJ
(245)

ENDRESS+HAUSER  FTL81-AASAABA1ABJVBJ

EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals.

FMP52-AAAAAACBTJK
(203)

ENDRESS+HAUSER  FMP52-AAAAAACBTJK

EH Levelflex FMP52 Guided Time-of-Flight Radar for level measurement with coated probe in aggressive liquids. DN50 to DN100 Process Connection. 2-wire or 4-wire HART communication. 304, 304L, 316, 316L, PTFE or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR57-AAAAAABCA6RGJ1
(196)

ENDRESS+HAUSER  FMR57-AAAAAABCA6RGJ1

EH Micropilot FMR57 Time-of-Flight Radar for continuous non-contact level measurement in bulk solids (highest demands). DN80 to DN100 Process Connection. 2-wire or 4-wire HART communication. 316L, PEEK, PTFE, Polyamid Main wetted parts. FM and CSA approvals.

FMR52-AAAAAABOCFK
(193)

ENDRESS+HAUSER  FMR52-AAAAAABOCFK

EH Micropilot FMR52 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids. DN50 to DN150 Process Connection. 2-wire or 4-wire HART communication. PTFE-filled and flush-mounted horn antenna. FM and CSA approvals.

Page: 1 | 2 | All