Process Control Instruments, Field Devices and Industrial Automation
SKU# (221)

ENDRESS+HAUSER  FMU90-L12KA111AA1A




ENDRESS+HAUSER FMU90-L12KA111AA1A (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Documents

EH Prosonic FMU90 Ultrasonic Time-of-Flight Transmitter for continuous and non-contact level measurement with up to 2 FDU90/91/92/93/95 sensors. Field or top hat rail housing. Up to 6 relays. 2-wire HART communication. IP66 / NEMA 4x. ATEX and CSA approvals.

Part# with Options:        FMU90-L12KA111AA1A
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMU90/95
Application
(2) Application for EH FMU90
Housing & Material
(3) Housing & Material for EH FMU90/95
Operation
(4) Operation for EH FMU90/95
Power Supply
(5) Power Supply for EH FMU90/95
Level Input
(6) Level Input for EH FMU90
Switch Output
(7) Switch Output for EH FMU90
Output
(8) Output for EH FMU90
Additional Input
(9) Additional Input for EH FMU90
Language
(10) Language for EH FMU90
Additional Option
(11) Additional Option EH FMU90

  Availability 7 Days  ]

Field of application

Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45 m (148 ft) and level limit detection. Pump control, rake control and as option: additional pump control function.

  • Calculations: average, difference, sum
  • Application flow: Flow measurement in open channels and weirs with 1 or 2 sensors
  • Flow measurement with back water or sludge detection
  • Up to 3 totalizers and 3 counters
  • Counting or time pulse output for control of external units
  • Transmitter available with field housing or top hat rail housing for control cabinet
  • instrumentation
Benefits
  • Simple, menu-guided operation with 6-line plain text display, 15 languages selectable
  • Envelope curves on the display for simple diagnosis
  • Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program
  • Time-of-flight correction via integrated or external temperature sensors
  • Linearisation (up to 32 points, freely configurable) for the most common flumes and weirs pre-programmed and selectable
  • Online calculation of the flume-/weir-flows via integrated flow curves
  • Field housing aluminium with ATEX II 3D certificate

Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake / limit control, 1 or 2 channel version
Specialities Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors
option: flow measurement for open channel and weirs or additional pump control functions
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
up to 2x 4...20mA HART
Profibus DP
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 C ... 60 C
(-40 F ... 140 F)
Communication up to 2x 4 ... 20 mA HART
Profibus DP
Certificates / Approvals ATEX, CSA
Options Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
Components Sensors FDU9x

  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU90-RG1AA EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/..
  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU91-RG1AA EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" P..
  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU91F-RF1A EH Prosonic FDU91F Ultrasonic Time-of-Flight level and flow hygienic sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-20mA HART communication. 316L main wetted parts. ..
  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU92-RG1A EH Prosonic FDU92 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 65ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1" P..
  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU93-RG1A EH Prosonic FDU93 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 85ft) with FMU9X. 4-20mA HART communication. UP main wetted parts. G/NPT 1" Pro..
  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU95-R1G1A EH Prosonic FDU95 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 148ft) with FMU9X. 4-20mA HART communication. UP main wetted parts. G/NPT 1" Pr..

  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU90-RG1AA EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, IN..


  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU91-RG1AA EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx ap..


  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU91F-RF1A EH Prosonic FDU91F Ultrasonic Time-of-Flight level and flow hygienic sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-20mA HART communication. 316L main wetted parts. G, NPT, DN80 or DN100 Process Connection. IP68. ATEX, FM, CS..


  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU92-RG1A EH Prosonic FDU92 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 65ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx ap..


  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU93-RG1A EH Prosonic FDU93 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 85ft) with FMU9X. 4-20mA HART communication. UP main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx appr..


  • ULTRASONIC SENSORS > HAZARDOUS LOCATIONS
    FDU95-R1G1A EH Prosonic FDU95 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 148ft) with FMU9X. 4-20mA HART communication. UP main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx app..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ULTRASONIC TRANSMITTERS > HAZARDOUS LOCATIONS :    47 Items found.
FTW31-A1A2EA0A
(264)

ENDRESS+HAUSER  FTW31-A1A2EA0A

EH Liquipoint FTW31 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTL325N-O1A1
(250)

ENDRESS+HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

FTW325-A2A1A
(266)

ENDRESS+HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

FMI21-A1D1A1
(233)

ENDRESS+HAUSER  FMI21-A1D1A1

EH Liquicap FMI21 Capacitive rod probe for continuos level measurement in conductive liquids. 316L, 1.4404 or PP wetted parts. NPT 1 1/2 or G 1 1/2 Process Connection. ATEX and CSA Approvals.

FTC262-AA32B1
(232)

ENDRESS+HAUSER  FTC262-AA32B1

EH Minicap FTC262 Capacitive rope probe for point level detection in light bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1 1/2 or R 1 1/2 Process Connection. PNP transistor and relay outputs. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

11375Z-RXG1A5A5
(257)

ENDRESS+HAUSER  11375Z-RXG1A5A5

EH 11375Z One rod probe for point level detection of conductive liquids with higher temperatures. 316Ti Rod. PTFE Partial Insulaion. G 1/2 Process Connection. Relay Communication. ATEX Approval.

11362Z-R1AA4A11CA
(259)

ENDRESS+HAUSER  11362Z-R1AA4A11CA

EH 11362Z Double rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FDU90-RG1AA
(211)

ENDRESS+HAUSER  FDU90-RG1AA

EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTC325-A2A31
(231)

ENDRESS+HAUSER  FTC325-A2A31

EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

FTM20-AA22A
(254)

ENDRESS+HAUSER  FTM20-AA22A

EH Soliphant FTM20 Vibronic Compact Point level limit switch for bulk solids in dust or hazardous areas. 1 1/4" NPT, 1 1/2" NPT or R Process Connection. ATEX, FM, CSA and IECEx approvals.

FDU91-RG1AA
(212)

ENDRESS+HAUSER  FDU91-RG1AA

EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTL50-AGE2AA1E4A
(237)

ENDRESS+HAUSER  FTL50-AGE2AA1E4A

EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11961Z-RCG1AB5
(256)

ENDRESS+HAUSER  11961Z-RCG1AB5

EH 11961Z One rod probe for point level detection of conductive liquids steam boilers. Highly resistant. 316Ti Rod. G 1/2 Process Connection. Relay Communication. ATEX Approval.

FTL51-AGE2DB1E4A
(241)

ENDRESS+HAUSER  FTL51-AGE2DB1E4A

EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11363Z-R1AA4A111CA
(260)

ENDRESS+HAUSER  11363Z-R1AA4A111CA

EH 11363Z Triple rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FTM21-AM622A
(255)

ENDRESS+HAUSER  FTM21-AM622A

EH Soliphant FTM21 Vibronic Compact Point level limit switch with extension tube for bulk solids in dust or hazardous areas. Stainless Steel Housing (316L). 1 1/4" NPT or 1 1/2" NPT Process Connection. ATEX, FM, CSA and IECEx approvals.

FTL325P-O1A1
(248)

ENDRESS+HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.

Page: 1 | 2 | 3 | All