Process Control Instruments, Field Devices and Industrial Automation
SKU# (223)

ENDRESS+HAUSER  FMI51-A1HGCJV2A1A




ENDRESS+HAUSER FMI51-A1HGCJV2A1A (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Liquicap FMI51 Capacitive Rod Probe for continuous level measurement in liquids (extremely high temperatures). HART communication. PFA or 316L main wetted parts. DN50 to D100 Process Connection. IP66. FM and CSA approvals.

Part# with Options:        FMI51-A1HGCJV2A1A
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMI51
Inactive Length L3
(2) Inactive Length L3 EH FMI51
Active Probe Length L1
(3) Active Probe Length L1 EH FMI51
Process Connection
(4) Process Connection EH FMI51
Electronics & Output
(5) Electronics & Output EH FMI51
Housing
(6) Housing EH FMI51
Cable Entry
(7) Cable Entry EH FMI51
Type of Probe
(8) Type of Probe EH FMI51
Additional Option
(9) Additional Option EH FMI51

  Availability 2 Weeks  ]

Application

The Liquicap M FMI5x compact transmitter is used for the continuous level measurement of liquids.

Thanks to its robust and tried-and-tested construction, the probe can be used both in vacuums and in overpressure up to 100 bar. The materials used allow operating temperatures in the medium container of 80 C to +200 C.

Used in conjunction with Fieldgate (remote measured value interrogation via the Internet), Liquicap M provides an ideal solution for inventorying materials and optimizing logistics (inventory control).

Your Benefits
  • No adjustment necessary for media with a conductivity of 100 μS/cm and higher. The probes are adjusted to the ordered probe length on leaving the factory (0 % to 100 %). This makes easy and fast commissioning possible.
  • Menu-guided local configuration via plain text display (optional)
  • Universal application thanks to wide range of certificates and approvals
  • Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
  • Corrosion-resistant, FDA-listed materials in contact with the process
  • Can be switched for media forming buildup
  • Short reaction times
  • No need for readjustment after replacing electronics
  • Automatic monitoring of electronics and possible damage to insulation, as well as rod breaking or rope tearing
  • Suitable for interface measurement
Measuring principle

The principle of capacitance level measurement is based on the change in capacitance of the capacitor due to the change in the level. The probe and container wall (conductive material) form an electric capacitor. When the probe is in air (1), a certain low initial capacitance is measured. When the container is filled, the capacitance increases the more the probe is covered (2), (3).

As of a conductivity of 100 μs/cm, the measurement is independent of the value for the dielectric constant (DK) of the liquid. As a result, fluctuations in the DK value do not affect the measured value display. Furthermore, the system also prevents the effect of medium buildup or condensate near the process connection for probes with an inactive length.

Measuring Principle Capacitive
Characteristic / Application Fully insulated rod probe, for standart- and extreme process conditions (temperature, pressure, build up)
Interface measurement Interfaces liquid / liquid also with emulsion layers
Specialities Inactive length
Factory calibrated
short response time by change of value
Supply / Communication 12-36V DC HART
PFM
Accuracy Repeatablity 0,1%
Linearity error for conductive liquids <0,25%
Ambient temperature -50C...+70C
-58F...+158F
Process temperature -80C...200C
-112F...392F
Process pressure absolute / max. overpressure limit Vacuum ... 100 bar
(Vaccum ... 1450 psi)
Main wetted parts Insulation material: PTFE,PFA
316L
Process connection G1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1", NPT1 1/2
Flanges from DN25.../ASME 1".../JIS...
Process connection hygienic Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal
Sensor length Total length: 6m (20ft)
Inactive length: max. 2m (7ft)
Max. measurement distance 0.1 m ... 4.0 m
(0.3 ft ... 13 ft)
Communication 4...20mA HART
PFM
Certificates / Approvals ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI
Safety approvals Overfill prevention WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175
Hygienic approvals 3A, EHEDG
Options Separate housing
gas-tight probe seal
Application limits Insufficient clearance towards ceiling
Changing, non-conductive media, conductivity < 100 μS/cm Notice the pressure and temperature derating


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CAPACITIVE PROBES > FM-CSA :    25 Items found.
FTI55-AAK1RG1W2A1A
(225)

ENDRESS+HAUSER  FTI55-AAK1RG1W2A1A

EH Solicap FTI55 Capacitive Point Level Rod Probe for bulk solids. NPT 1 1/2 Process Connection. PE, PPS, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI56-AAM1RG1W2A1A
(230)

ENDRESS+HAUSER  FTI56-AAM1RG1W2A1A

EH Liquicap FTI56 Capacitive Point Level Rope Probe for bulk solids. R/NPT 1 1/2 Process Connection. PTFE, PA, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI51-AAH1GCJW2A1A
(224)

ENDRESS+HAUSER  FTI51-AAH1GCJW2A1A

EH Liquicap FTI51 Capacitive Point Level Rod Probe for highly viscous liquids. G/NPT 1/2 to G/NPT 1 1/2 Process Connection. PTFE, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FTI52-AAC1GDJW2A1A
(228)

ENDRESS+HAUSER  FTI52-AAC1GDJW2A1A

EH Liquicap FTI52 Capacitive Point Level Rope Probe for highly viscous liquids. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. FEP, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FMI52-A1CGDJV2A1A
(229)

ENDRESS+HAUSER  FMI52-A1CGDJV2A1A

EH Liquicap FMI52 Capacitive Rod Probe for continuous level measurement in liquids (large ranges). HART communication. FEP, PFA or 316L main wetted parts. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. IP66/67. FM and CSA approvals.

FMU40-ANB1A2
(217)

ENDRESS+HAUSER  FMU40-ANB1A2

EH Prosonic FMU40 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 16ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. G/NPT 1 1/2" Process Connection. FM and CSA approvals.

FMP50-AAAAAAAAA1GDJ
(201)

ENDRESS+HAUSER  FMP50-AAAAAAAAA1GDJ

EH Levelflex FMP50 Guided Time-of-Flight Radar for level measurement in liquids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 316L, PPS or Viton main wetted parts. IP66/68 NEMA4X/6P. FM and CSA approvals.

FTI77-A1AVVRG1W2A1A
(227)

ENDRESS+HAUSER  FTI77-A1AVVRG1W2A1A

EH Solicap FTI77 Capacitive Point Level Rod Probe for bulk solids in high temperatures. R 1 1/2 or NPT 1 1/2 Process Connection. Ceramic, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FMU42-AMB1A22A
(218)

ENDRESS+HAUSER  FMU42-AMB1A22A

EH Prosonic FMU42 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 33ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN80 or DN100 Process Connection. FM and CSA approvals.

FMP56-AAAAAALBABGDE
(206)

ENDRESS+HAUSER  FMP56-AAAAAALBABGDE

EH Levelflex FMP56 Guided Time-of-Flight Radar for continuos level measurement in bulk solids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMP51-AAAAAAABA4GDJ
(202)

ENDRESS+HAUSER  FMP51-AAAAAAABA4GDJ

EH Levelflex FMP51 Guided Time-of-Flight Radar for level measurement for highest demands in liquids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 316, 316L, Alloy C, Ceramic or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR50-AAAAAABMGGF
(190)

ENDRESS+HAUSER  FMR50-AAAAAABMGGF

EH Micropilot FMR50 Time-of-Flight Radar for continuos level measurement in liquids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. Encapsulated PVDF or PP clad horn antenna. FM and CSA approvals.

FMU44-AMB1A22A
(220)

ENDRESS+HAUSER  FMU44-AMB1A22A

EH Prosonic FMU44 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 66ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN100 to DN200 Process Connection. FM and CSA approvals.

FMR56-AAAAAABNXR0
(195)

ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

FMP57-AAAAAAAFA4GGE
(207)

ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FTL80-AASAABA1AAJVBJ
(240)

ENDRESS+HAUSER  FTL80-AASAABA1AAJVBJ

EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CSA approvals.

FTL81-AASAABA1ABJVBJ
(245)

ENDRESS+HAUSER  FTL81-AASAABA1ABJVBJ

EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals.

FMP52-AAAAAACBTJK
(203)

ENDRESS+HAUSER  FMP52-AAAAAACBTJK

EH Levelflex FMP52 Guided Time-of-Flight Radar for level measurement with coated probe in aggressive liquids. DN50 to DN100 Process Connection. 2-wire or 4-wire HART communication. 304, 304L, 316, 316L, PTFE or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR57-AAAAAABCA6RGJ1
(196)

ENDRESS+HAUSER  FMR57-AAAAAABCA6RGJ1

EH Micropilot FMR57 Time-of-Flight Radar for continuous non-contact level measurement in bulk solids (highest demands). DN80 to DN100 Process Connection. 2-wire or 4-wire HART communication. 316L, PEEK, PTFE, Polyamid Main wetted parts. FM and CSA approvals.

FMR52-AAAAAABOCFK
(193)

ENDRESS+HAUSER  FMR52-AAAAAABOCFK

EH Micropilot FMR52 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids. DN50 to DN150 Process Connection. 2-wire or 4-wire HART communication. PTFE-filled and flush-mounted horn antenna. FM and CSA approvals.

Page: 1 | 2 | All