EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

Part# with Options:        FTL50-AGE2AA1E4A
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FTL5X & FTL5XH
Process Connection
(2) Process Connection for EH FTL5H
Probe Length & Type
(3) Probe Length & Type for EH FTL50
Electronics & Output
(4) Electronics & Output for EH FTL5X & FTL5XH
Housing & Cable Entry
(5) Housing & Cable Entry for EH FTL5X
Additional Option
(6) Additional Option for EH FTL50

  Availability 8 Days  ]

Applications
  • Process temperatures from 50 C to 150 C (-58 to 302 F)
  • Pressures up to 100 bar (1450 psi)
  • Viscosities up to 10,000 mm2 /s (cSt)
  • For liquids with densities >= 0.5 g/cm3 (SGU)

FTL50: Compact design
FTL51: Extension pipe up to 3 m (9.8 ft) and up to 6 m (20 ft) on request
FTL50H, FTL51H: Certified for the food and pharmaceutical industries

Ideal substitute for float switches, as reliable function not affected by flow, turbulence, bubbles, foam, vibration, solids content or buildup.

Your Benefits
  • Recommended for safety systems requiring functional safety to SIL2/SIL3 as per IEC 61508/IEC 61511-1
  • Design in accordance with ASME B31.3
  • Recommended for use in sterile applications in the life science industry (design in accordance with ASME BPE)
  • No adjustment: quick, low-cost startup
  • No mechanically moving parts: no maintenance, no wear, long operating life
  • Functional safety: Monitoring of tuning fork for damage
  • Compact stainless steel housing (optional): the IP69 protection rating guarantees that the unit remains impermeable, even in the event of intensive cleaning or flooding for several hours
Point level detection

Maximum or minimum detection in tanks or pipes containing all kinds of liquids, including use in hazardous areas, food and pharmaceuticals.

Measuring principle

The sensor's fork vibrates at its intrinsic frequency. This frequency is reduced when covered with liquid. This change in frequency causes the point level switch to switch.

Measuring Principle Vibration Liquids
Characteristic / Application Modular housing concept
wide range of process connections
Analogue and bus interfaces
Extensive certificate range (e.g. Ex,WHG)
compact, e.g. pipes
Specialities Foamdetection
Detekt a densitychange
second line of defense
Supply / Communication PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC or 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM
Ambient temperature -50 C...+70 C
(-58 F...+158 F)
Process temperature -50 C...+150 C
(-58 F...+302 F)
Process pressure absolute / max. overpressure limit Vacuum...64 bar
(Vacuum...928 psi)
Min. density of medium 0.5g/cm(0.4g/cm option)
Main wetted parts 316L, Alloy
Process connection Thread:
G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
Flange:
DN25...DN100,
ASME 1"...4",
JIS 25A...100A
Process connection hygienic Tri-Clamp ISO2852
Communication PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC or 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM
Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
Safety approvals Overfill prevention WHG
SIL2/ SIL3
Design approvals EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000
Marine approval GL/ ABS
Options Heavy duty stainless steel housing mainly for the oil and gas industry
Components FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR

  • SWITCHING UNITS > HAZARDOUS LOCATIONS
    FTL325P-O1A1 EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals...


  • SWITCHING UNITS > HAZARDOUS LOCATIONS
    FTL375P-F1E1 EH Nivotester FTL375P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. 19" circuit board. Intrinsically safe signal circuit. 20-30VDC. Racksyst 4HP Housing. SIL3 safety approval. ATEX approval...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> VIBRATION SWITCHES > HAZARDOUS LOCATIONS :    47 Items found.
FTW31-A1A2EA0A
(264)

ENDRESS+HAUSER  FTW31-A1A2EA0A

EH Liquipoint FTW31 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTL325N-O1A1
(250)

ENDRESS+HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

FTW325-A2A1A
(266)

ENDRESS+HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

FMI21-A1D1A1
(233)

ENDRESS+HAUSER  FMI21-A1D1A1

EH Liquicap FMI21 Capacitive rod probe for continuos level measurement in conductive liquids. 316L, 1.4404 or PP wetted parts. NPT 1 1/2 or G 1 1/2 Process Connection. ATEX and CSA Approvals.

FTC262-AA32B1
(232)

ENDRESS+HAUSER  FTC262-AA32B1

EH Minicap FTC262 Capacitive rope probe for point level detection in light bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1 1/2 or R 1 1/2 Process Connection. PNP transistor and relay outputs. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

11375Z-RXG1A5A5
(257)

ENDRESS+HAUSER  11375Z-RXG1A5A5

EH 11375Z One rod probe for point level detection of conductive liquids with higher temperatures. 316Ti Rod. PTFE Partial Insulaion. G 1/2 Process Connection. Relay Communication. ATEX Approval.

11362Z-R1AA4A11CA
(259)

ENDRESS+HAUSER  11362Z-R1AA4A11CA

EH 11362Z Double rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FDU90-RG1AA
(211)

ENDRESS+HAUSER  FDU90-RG1AA

EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTC325-A2A31
(231)

ENDRESS+HAUSER  FTC325-A2A31

EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

FTM20-AA22A
(254)

ENDRESS+HAUSER  FTM20-AA22A

EH Soliphant FTM20 Vibronic Compact Point level limit switch for bulk solids in dust or hazardous areas. 1 1/4" NPT, 1 1/2" NPT or R Process Connection. ATEX, FM, CSA and IECEx approvals.

FDU91-RG1AA
(212)

ENDRESS+HAUSER  FDU91-RG1AA

EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

11961Z-RCG1AB5
(256)

ENDRESS+HAUSER  11961Z-RCG1AB5

EH 11961Z One rod probe for point level detection of conductive liquids steam boilers. Highly resistant. 316Ti Rod. G 1/2 Process Connection. Relay Communication. ATEX Approval.

FTL51-AGE2DB1E4A
(241)

ENDRESS+HAUSER  FTL51-AGE2DB1E4A

EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11363Z-R1AA4A111CA
(260)

ENDRESS+HAUSER  11363Z-R1AA4A111CA

EH 11363Z Triple rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FTM21-AM622A
(255)

ENDRESS+HAUSER  FTM21-AM622A

EH Soliphant FTM21 Vibronic Compact Point level limit switch with extension tube for bulk solids in dust or hazardous areas. Stainless Steel Housing (316L). 1 1/4" NPT or 1 1/2" NPT Process Connection. ATEX, FM, CSA and IECEx approvals.

FTL325P-O1A1
(248)

ENDRESS+HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.

FTL50H-AGQ2AC1E4A
(238)

ENDRESS+HAUSER  FTL50H-AGQ2AC1E4A

EH Liquiphant FTL50H Vibronic Compact Point level switch for liquids in food industry (hygienic). Hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.