Process Control Instruments, Field Devices and Industrial Automation
SKU# (246)

ENDRESS+HAUSER  FTL85-AASAABN1NBNEZN




ENDRESS+HAUSER FTL85-AASAABN1NBNEZN (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Liquiphant FTL85 Vibronic Coated Point level switch for liquids in hazardous areas. FailSafe overfill prevention. DN25 to DN100 Process Connection. SIL3 safety approval. FM and CSA approvals.

Part# with Options:        FTL85-AASAABN1NBNEZN
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FTL8X
Housing
(2) Housing for EH FTL8X
Electrical Connection
(3) Electrical Connection for EH FTL8X
Application
(4) Application for EH FTL85
Sensor Material
(5) Sensor Material for EH FTL85
Surface Refinement
(6) Surface Refinement for EH FTL85
Sensor Type
(7) Sensor Type for EH FTL85
Process Connection
(8) Process Connection for EH FTL85

  Availability 3 Weeks  ]

Applications

The Liquiphant FailSafe is a point level switch for minimum and maximum detection (MIN/MAX) which can be used in liquids:

  • Process temperatures 60 to 280 C (76 to 536 F)
  • Ambient temperatures 60 to 70 C (76 to 158 F)
  • For highly corrosive media
  • Pressures up to 100 bar (1450 psi)
  • Viscosity up to 10000 mPas
  • Density from 0.4 g/cm3 (0.4 SGU)

Liquiphant FailSafe is the reliable point level switch for MIN and MAX safety applications up to SIL3.

Outstanding features of the point level switch are its fail- safe design and its high availability.

A permanent LIVE signal also monitors function safety.

Your Benefits
  • 4-20 mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
  • Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
  • Proof test: proof testing interval up to 12 years
  • Slave devices tested at the press of a button
  • Permanent self-monitoring/internal redundancy
  • No adjustment: quick, low-cost startup
  • No mechanically moving parts: no maintenance, no wear, long operating life
  • Monitoring of fork for damage, corrosion, buildup and mechanical blocking
  • 2. process seal (2 nd line of defense) is provided as standard in the high-temperature version or can be optionally selected for all other versions
Point level detection

Maximum or minimum detection for liquids in tanks or pipes (leak monitoring, dry running protection/pump protection or overfill protection), particularly for the chemical, energy and oil & gas industry.

Special versions are suitable for use in hazardous areas and for applications with high pressures. As a coated version, the Liquiphant FailSafe is highly resistant to corrosion, making it particularly suitable for very aggressive liquids.

The point level switches make a distinction between two states: "covered" and "exposed" Depending on whether you have selected the MIN (minimum detection) or MAX (maximum detection) operating mode, this results in two specific scenarios in each case: the "Good" state and demand mode.

"Good" state:
The fork is covered in the MIN operating mode (e.g. pump protection).
The fork is exposed (uncovered) in the MAX operating mode (e.g. overfill protection).

Demand mode:
The fork is exposed (uncovered) in the MIN operating mode (e.g. pump protection).
The fork is covered in the MAX operating mode (e.g. overfill protection).

Measuring principle

The sensor's fork vibrates at its intrinsic frequency. When the tuning fork is immersed in a liquid, its intrinsic frequency changes due to the change in density of the surrounding medium. This change in frequency causes the current signal to switch.

Measuring Principle Vibration Liquids
Characteristic / Application Coated point level switch for MIN and MAX safety applications up to SIL3,
Dual Sealing/ Second line of defense,
Modular housing concept
Specialities Outstanding features: - permanent LIVE signal monitors function safety
- failsafe design and
- high availability of the measuring values
Supply / Communication 2-wire 4...20 mA
Ambient temperature -50C...+70C
(-58F...+160F)
Process temperature 50C...+150C
(58F...+300F)
Process pressure absolute / max. overpressure limit Vacuum...40 bar
(580 psi)
Min. density of medium Density from 0.4 g/cm3
(0.4 SGU)
Main wetted parts With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials
Process connection Flange:
DN25...DN100,
ASME 1"...4",
JIS 10K...20K
Sensor length Extension pipe up to 3 m (9.8 ft)
Communication 2-wire 4...20 mA
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI
Safety approvals Overfill prevention WHG
Leakage Detection
SIL3
Options AlloyC Material
PWIS free
Pressure tight feed through
Weather protection
Components Nivotester FTL825, Transmitter

  • SWITCHING UNITS > HAZARDOUS LOCATIONS
    FTL825-AA3A4 EH Nivotester FTL825 Vibronic Point level switching unit for Liquiphant FTL80, FTL81 and FTL85. DIN-Rail. FailSafe overfill prevention. 2 SPST safety contact point level, 1 SPST signal contact and 1 SPDT fault contact. SIL3 safety approval. ATEX, FM and C..


  • SWITCHING UNITS > HAZARDOUS LOCATIONS
    FTL325P-O1A1 EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals...


  • SWITCHING UNITS > HAZARDOUS LOCATIONS
    FTL375P-F1E1 EH Nivotester FTL375P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. 19" circuit board. Intrinsically safe signal circuit. 20-30VDC. Racksyst 4HP Housing. SIL3 safety approval. ATEX approval...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> VIBRATION SWITCHES > FM-CSA :    25 Items found.
FTI55-AAK1RG1W2A1A
(225)

ENDRESS+HAUSER  FTI55-AAK1RG1W2A1A

EH Solicap FTI55 Capacitive Point Level Rod Probe for bulk solids. NPT 1 1/2 Process Connection. PE, PPS, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI56-AAM1RG1W2A1A
(230)

ENDRESS+HAUSER  FTI56-AAM1RG1W2A1A

EH Liquicap FTI56 Capacitive Point Level Rope Probe for bulk solids. R/NPT 1 1/2 Process Connection. PTFE, PA, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI51-AAH1GCJW2A1A
(224)

ENDRESS+HAUSER  FTI51-AAH1GCJW2A1A

EH Liquicap FTI51 Capacitive Point Level Rod Probe for highly viscous liquids. G/NPT 1/2 to G/NPT 1 1/2 Process Connection. PTFE, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FTI52-AAC1GDJW2A1A
(228)

ENDRESS+HAUSER  FTI52-AAC1GDJW2A1A

EH Liquicap FTI52 Capacitive Point Level Rope Probe for highly viscous liquids. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. FEP, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FMI52-A1CGDJV2A1A
(229)

ENDRESS+HAUSER  FMI52-A1CGDJV2A1A

EH Liquicap FMI52 Capacitive Rod Probe for continuous level measurement in liquids (large ranges). HART communication. FEP, PFA or 316L main wetted parts. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. IP66/67. FM and CSA approvals.

FMI51-A1HGCJV2A1A
(223)

ENDRESS+HAUSER  FMI51-A1HGCJV2A1A

EH Liquicap FMI51 Capacitive Rod Probe for continuous level measurement in liquids (extremely high temperatures). HART communication. PFA or 316L main wetted parts. DN50 to D100 Process Connection. IP66. FM and CSA approvals.

FMU40-ANB1A2
(217)

ENDRESS+HAUSER  FMU40-ANB1A2

EH Prosonic FMU40 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 16ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. G/NPT 1 1/2" Process Connection. FM and CSA approvals.

FMP50-AAAAAAAAA1GDJ
(201)

ENDRESS+HAUSER  FMP50-AAAAAAAAA1GDJ

EH Levelflex FMP50 Guided Time-of-Flight Radar for level measurement in liquids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 316L, PPS or Viton main wetted parts. IP66/68 NEMA4X/6P. FM and CSA approvals.

FTI77-A1AVVRG1W2A1A
(227)

ENDRESS+HAUSER  FTI77-A1AVVRG1W2A1A

EH Solicap FTI77 Capacitive Point Level Rod Probe for bulk solids in high temperatures. R 1 1/2 or NPT 1 1/2 Process Connection. Ceramic, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FMU42-AMB1A22A
(218)

ENDRESS+HAUSER  FMU42-AMB1A22A

EH Prosonic FMU42 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 33ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN80 or DN100 Process Connection. FM and CSA approvals.

FMP56-AAAAAALBABGDE
(206)

ENDRESS+HAUSER  FMP56-AAAAAALBABGDE

EH Levelflex FMP56 Guided Time-of-Flight Radar for continuos level measurement in bulk solids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMP51-AAAAAAABA4GDJ
(202)

ENDRESS+HAUSER  FMP51-AAAAAAABA4GDJ

EH Levelflex FMP51 Guided Time-of-Flight Radar for level measurement for highest demands in liquids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 316, 316L, Alloy C, Ceramic or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR50-AAAAAABMGGF
(190)

ENDRESS+HAUSER  FMR50-AAAAAABMGGF

EH Micropilot FMR50 Time-of-Flight Radar for continuos level measurement in liquids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. Encapsulated PVDF or PP clad horn antenna. FM and CSA approvals.

FMU44-AMB1A22A
(220)

ENDRESS+HAUSER  FMU44-AMB1A22A

EH Prosonic FMU44 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 66ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN100 to DN200 Process Connection. FM and CSA approvals.

FMR56-AAAAAABNXR0
(195)

ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

FMP57-AAAAAAAFA4GGE
(207)

ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FTL80-AASAABA1AAJVBJ
(240)

ENDRESS+HAUSER  FTL80-AASAABA1AAJVBJ

EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CSA approvals.

FTL81-AASAABA1ABJVBJ
(245)

ENDRESS+HAUSER  FTL81-AASAABA1ABJVBJ

EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals.

FMP52-AAAAAACBTJK
(203)

ENDRESS+HAUSER  FMP52-AAAAAACBTJK

EH Levelflex FMP52 Guided Time-of-Flight Radar for level measurement with coated probe in aggressive liquids. DN50 to DN100 Process Connection. 2-wire or 4-wire HART communication. 304, 304L, 316, 316L, PTFE or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR57-AAAAAABCA6RGJ1
(196)

ENDRESS+HAUSER  FMR57-AAAAAABCA6RGJ1

EH Micropilot FMR57 Time-of-Flight Radar for continuous non-contact level measurement in bulk solids (highest demands). DN80 to DN100 Process Connection. 2-wire or 4-wire HART communication. 316L, PEEK, PTFE, Polyamid Main wetted parts. FM and CSA approvals.

Page: 1 | 2 | All