InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(249) Be the First to Review this Item

ENDRESS-HAUSER  FTL375P-F1E1

LEVEL / SWITCHING UNITS
HAZARDOUS LOCATIONS

$1,012.20     Availability: 5 Days
 Information Request
 Shipping Rates
 Volume discount
      



ENDRESS-HAUSER FTL375P-F1E1 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Nivotester FTL375P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. 19" circuit board. Intrinsically safe signal circuit. 20-30VDC. Racksyst 4HP Housing. SIL3 safety approval. ATEX approval.

Part# with Options:        FTL375P-F1E1
Price with Options:        1,012.20

Options:    

Approval
(1) Approval for EH FTL375P
Switch Output
(2) Switch Output for EH FTL375P

  Availability 5 Days  ]

Applications
  • Level limit detection in liquid tanks and bulk material silos, also in hazardous explosion areas
  • For Zone 0 or Zone 20 measuring cells
  • Liquid detection in pipes for dry running protection for pumps
  • Overspill protection for tanks with combustible or non-combustible liquids harmful to water
  • Two-point control and level limit detection with one switching instrument
  • Application in safety related systems with requirements for functional safety up to SIL3 in accordance to IEC 61508 when using Liquiphant M/S with electronic insert FEL 57
Your Benefits
  • Nivotester FTL 375 P for connecting one, two or three measuring cells (1-, 2- or 3-channel devices).
  • Intrinsically safe signal circuits [EEx ia] for installing measuring cells in explosion hazardous areas.
  • Functional safety to SIL (see also Functional Safety manual SD 113F) through the use of:
    • fail-safe PFM technology
    • line monitoring through to sensor
    • Monitoring for corrosion on tuning forks of Liquiphant M and Liquiphant S (HT) measuring cells
    • Simplified iterative testing to WHG when Liquiphant M or Liquiphant S (HT) connected: at the press of a button
  • Racksyst plug-in card in Europa card format to DIN 41494, 4 HP wide, 3 HU high
  • Same device for mounting either in 19" assembly rack or single Monorack housing for 1-channel and 2-channel devices
  • Intensive quality control measures: from isolating amplifier through to measuring cell
  • Inputs are galvanically isolated from each other, from the mains and from
  • the outputs compatible with Nivotester FTL 370/FTL 372
  • additional binary outputs
Signal transmission

The intrinsically safe signal inputs of the Nivotester FTL 375 P limit switch are galvanically isolated from each other, from the mains and from the outputs.

The Nivotester supplies direct current to the Liquiphant, Nivopuls or Soliphant measuring cells via two-wire cabling and receives a frequency which indicates whether the limit has been reached or not. The supply current is superimposed by the transmitters with current pulses (PFM signals) which have a pulse width of approx. 200 μs and a current intensity of approx. 10 mA.

Signal evaluation

The Nivotester evaluates the frequency and switches the output relay for the level alarm. At the same time the binary output transistor, which is parallel to the relay, switches. The switching state of the relay is displayed on the front panel of the Nivotester by means of a yellow light emitting diode.

Fail-safe mode

By selecting the "Maximum / Minimum" fail-safe circuit (the hook switch closes or opens), the output relay or the transistor outputs always operate safely in quiescent current.

Maximum safety: The relay drops off or the transistor output is disabled when the switch point is exceeded (measuring cell covered), a fault occurs or the line voltage fails.

Minimum safety: The relay drops off or the transistor output is disabled when the switch point is undershot (measuring cell uncovered), a fault occurs or the line voltage fails.

Measuring Principle Vibration Liquids
Characteristic / Application Level isolating switching amplifier
Function is monitored
SIL2/3 according to IEC61508/61511 (FDIS)
19" circuit board
Up to 3 measuring devices possible
Supply / Communication PFM
Relay
Ambient temperature -20 C ... 70 C
(-4 F ... 158 F)
Communication Up to 3 relays and 3 transistor outputs
Certificates / Approvals ATEX, TIIS
Safety approvals Overfill prevention WHG
SIL


  • VIBRATION SWITCHES > GENERAL PURPOSE
    FTL31-AA4M2AAVAJ EH Liquiphant FTL31 Vibronic Point Vibration Level Switch for liquids. Robust stainless steel housing and compact design. Not suitable for hazardous areas. LED indicator. CSA approval...


  • VIBRATION SWITCHES > GENERAL PURPOSE
    FTL33-AA4M2ABVAJ EH Liquiphant FTL33 Vibronic Point Vibration Level Switch for liquids in the food sector. Robust stainless steel housing. CIP and SIP cleanability guaranteed. LED indicator. 3-A and EHEDG certificates...


  • VIBRATION SWITCHES > HAZARDOUS LOCATIONS
    FTL50-AGE2AA1E4A EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals...


  • VIBRATION SWITCHES > HAZARDOUS LOCATIONS
    FTL70-AGE2AB1E4AL EH Liquiphant FTL70 Vibronic Compact Point level switch for liquids in high-temperature applications. Hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL safety approval. ATEX, FM and CSA approvals...


  • VIBRATION SWITCHES > FM-CSA
    FTL80-AASAABA1AAJVBJ EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CS..


  • VIBRATION SWITCHES > HAZARDOUS LOCATIONS
    FTL51-AGE2DB1E4A EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals...


  • VIBRATION SWITCHES > HAZARDOUS LOCATIONS
    FTL71-AGE2CB1E4AL EH Liquiphant FTL71 Vibronic Point level switch with extension tube for liquids in high-temperature applications. Hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL safety approval. ATEX, FM and CSA approvals...


  • VIBRATION SWITCHES > FM-CSA
    FTL81-AASAABA1ABJVBJ EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals...


  • VIBRATION SWITCHES > FM-CSA
    FTL85-AASAABN1NBNEZN EH Liquiphant FTL85 Vibronic Coated Point level switch for liquids in hazardous areas. FailSafe overfill prevention. DN25 to DN100 Process Connection. SIL3 safety approval. FM and CSA approvals...



B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> SWITCHING UNITS > HAZARDOUS LOCATIONS :    6 Items found.
FTL325N-O1A1 (250) ENDRESS-HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

  

$150.08        

 
FTW325-A2A1A (266) ENDRESS-HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

  

$177.39        

 
FTC325-A2A31 (231) ENDRESS-HAUSER  FTC325-A2A31

EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

  

$438.45        

 
FTL325P-O1A1 (248) ENDRESS-HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.

  

$607.15        

 
FTR325-B1A1 (270) ENDRESS-HAUSER  FTR325-B1A1

EH Nivotester FTR325 Microwave Barrier Switch amplifier for Soliwave FQR50/FDR50. 1 channel. Relay and DPDT communication. Rail Mounting. SPDT level and SPST alarm/level outputs. ATEX and IECEx Approvals.

  

$1,303.97        

 
FTL825-AA3A4 (247) ENDRESS-HAUSER  FTL825-AA3A4

EH Nivotester FTL825 Vibronic Point level switching unit for Liquiphant FTL80, FTL81 and FTL85. DIN-Rail. FailSafe overfill prevention. 2 SPST safety contact point level, 1 SPST signal contact and 1 SPDT fault contact. SIL3 safety approval. ATEX, FM and CSA approvals.

  

$2,104.12        

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
FTL375P-F1E1

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store