Process Control Instruments and Field Devices
ENDRESS+HAUSER CPS72D-7PT2C (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Ceragel CPS72D Digital ORP Memosens glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68. ATEX, FM and CSA approval.

Part# with Options:        CPS72D-7PT2C
Price with Options:        Please Email us your request for quote   

Options:    

Shaft Length
(1) Shaft Length for EH CPS72D
Approval
(2) Approval for EH CPS41D/42D/72D

  Availability 4 Weeks  ]

For process technology, hygienic and sterile applications with poison-resistant reference with ion trap

Application
  • Hygienic and sterile applications (sterilizable, autoclavable)
    • Fermenters
    • Biotechnology
    • Pharmaceutical industry
    • Food industry
  • Process technology and monitoring of processes with:
    • Rapidly changing ORP measured values
    • High proportion of electrode poisons such as H 2 S

With ATEX, FM and CSA approval for use in hazardous areas

Your benefits
  • Certified biocompatibility, no cytotoxicity
  • Acrylamide-free bridging electrolyte
  • Integrated temperature sensor in the case of Memosens
  • Poison-resistant reference with ion trap, resulting in a very long service life
  • Bridging electrolyte free of silver ions
  • Suitable for CIP/SIP cleaning and autoclavable, depending on version up to 140 C (284 F)
Measuring principle ORP measurement

The oxidation-reduction potential is an indicator of the equilibrium between oxidizing and reducing substances in the medium. The oxidation-reduction potential is measured with a gold or platinum electrode instead of the pH-sensitive glass membrane. As in the case of pH measurement, an integrated Ag/AgCl reference system is used as the reference electrode.

Measuring system

A complete measuring system comprises:

  • ORP electrode CPS72 or CPS72D
  • Transmitter, e.g. Liquiline CM42 or Liquiline CM44x (for CPS72D with Memosens technology)
  • Special measuring cable. e.g. CPK9 or Memosens data cable CYK10 for CPS72D
  • Immersion, flow or retractable assembly, e.g. Cleanfit H CPA475

Measuring principle

Sensor ORP / Redox

Application

- Hygienic and sterile applications - pharmaceuticals, biotechnology, fermenters, contaminating media.

Characteristic

- Digital electrode with Memosens-Technology.- Gel-compact-electrode with ceramic diaphragm.- Platinum-cap- CIP/SIP and autoclavable- high accuracy

Measurement range

-1500 mV - +1500 mV

Measuring principle

- ceramic diaphragm - double chamber and double gel reference - platinum-ring

Dimension

Diameter: 12 mm
Shaft lengths: 120, 225, 360 mm

Process temperature

-15C - 140C

Process pressure

max. 16bar

Ex certification

ATEX
FM
CSA

Connection

Inductive transmission of digital measuring signals.

Ingres protection

IP68

Additional certifications

EHEDG

Export Info
Made inGermany

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..

  • ORP ELECTRODES > GENERAL PURPOSE
    CPS72-0PT2ESA EH Ceragel CPS72 Analog ORP glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA250-A00 EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA450-0B110 EH Cleanfit CPA450 Manual retractable assembly for water & wastewater, chemical, pulp & paper and power industries. Accepts 12mm DO, pH and ORP sensors. DN32 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA472D-A4A1C1D1 EH Cleanfit CPA472D Manual or automatic process retractable heavy-duty assembly for chemical and power industries. Accepts pH and ORP electrodes. DN50/80 Process Connection. ..

  • PH ANALIZERS > CABLES
    CPK9-NHA1A EH CPK9 Measuring Cable for Analog Sensors. IP68 ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH-ORP-OXYGEN ELECTRODES > ASSEMBLY
    CPA442-A1D1B11 EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HAZARDOUS LOCATIONS :    41 Items found.
CPS41-1AB2SSA
(379)

ENDRESS+HAUSER  CPS41-1AB2SSA

EH Ceraliquid CPS41 analog pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS19-A1A1D
(370)

ENDRESS+HAUSER  CLS19-A1A1D

EH Condumax CLS19 2-electrode Analog conductive conductivity sensor for pure and ultrapure water applications. NPT 1/2" Process Connection. IP65. ATEX Approval.

CPS42-0PB2SSA
(381)

ENDRESS+HAUSER  CPS42-0PB2SSA

EH Ceraliquid CPS42 analog ORP glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12-0NA2ESA
(376)

ENDRESS+HAUSER  CPS12-0NA2ESA

EH Orbisint CPS12 Analog ORP glass electrode sensor for standard applications in process and environmental technology. PTFE diaphragm. -1500 mV to +1500 mV measurement range. 230 psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12D-7NA2C
(377)

ENDRESS+HAUSER  CPS12D-7NA2C

EH Orbisint CPS12D Digital ORP glass electrode Memosens sensor for standard applications in process and environmental technology. Teflon diaphragm. -1500 mV to +1500 mV measurement range. 16bar max pressure. Pt1000 Temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS71D-7TB2C
(363)

ENDRESS+HAUSER  CPS71D-7TB2C

EH Ceragel CPS71D Digital pH Memosens glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. NTC 30k temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS42D-7PB4AC
(382)

ENDRESS+HAUSER  CPS42D-7PB4AC

EH Ceraliquid CPS42D digital ORP Memosens glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS41D-7AB4AC
(380)

ENDRESS+HAUSER  CPS41D-7AB4AC

EH Ceraliquid CPS41D Memosens digital pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. NTC 30k Temperature Sensor. IP68. ATEX, FM and CSA approvals.

CPS471-2ESB1
(385)

ENDRESS+HAUSER  CPS471-2ESB1

EH Tophit CPS471 analog pH sensor with ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS171D-AA7NTP2
(353)

ENDRESS+HAUSER  CPS171D-AA7NTP2

EH Memosens CPS171D Digital Sensor with glass electrode for pH measurement on hygienic and sterile applications (bioreactors and fermenters). 0 - 14 pH measurement range. 0 to 102 psi process pressure. NTC 30k temperature sensor. ATEX, CSA, FM and IECEx approvals.

CPS491-2ESB2
(387)

ENDRESS+HAUSER  CPS491-2ESB2

EH Tophit CPS491 analog pH sensor with ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS471D-721C
(386)

ENDRESS+HAUSER  CPS471D-721C

EH Tophit CPS471D digital pH sensor with Memosens ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. Pt1000 temperatura sensor. IP68. ATEX, FM and CSA approvals.

CPS491D-722C
(388)

ENDRESS+HAUSER  CPS491D-722C

EH Tophit CPS4901D digital pH sensor with Memosens ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. Pt1000 temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS441-2ESC1
(383)

ENDRESS+HAUSER  CPS441-2ESC1

EH Tophit CPS441 analog pH sensor with ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS441D-72B1C
(384)

ENDRESS+HAUSER  CPS441D-72B1C

EH Tophit CPS441D Digital pH sensor with Memosens ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

Page: 1 | 2 | 3 | All