Process Control Instruments and Field Devices
ENDRESS+HAUSER 5H2B15-AAAACA00000A (1)
  • Overview
  • Features
  • Specs
  • Related
  • Literature

EH Proline Promag H 200 Electromagnetic Flowmeter with loop-powered technology for smallest flow rates. 0.06 dm³/min to 300 m³/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

Part# with Options:        5H2B15-AAAACA00000A
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH Promag H200
Output
(2) Output for EH Promag H200
Display & Operation
(3) Display & Operation for EH Promag H200
Housing
(4) Housing for EH Promag H200
Electrical Connection
(5) Electrical Connection for EH Promag H200
Seal
(6) Seal for EH Promag H200 & H300
Process Connection
(7) Process Connection for EH Promag H200
Electrodes
(8) Electrodes for EH Promag H200
Calibration Flow
(9) Calibration Flow for EH Promag H200

  Availability 10 Days  ]

The measuring device for smallest flow rates with genuine two-wire technology

Application
  • The measuring principle is virtually independent of pressure, density, temperature and viscosity
  • For the smallest flow quantities and demanding hygienic applications
Device properties
  • Liner made of PFA
  • Sensor housing made of stainless steel (3A, EHEDG)
  • Wetted materials CIP, SIP cleanable
  • Loop-powered technology
  • Robust two-chamber housing
  • Plant safety: worldwide approvals (SIL, Haz. area)
Your benefits
  • Flexible installation concept – numerous hygienic process connections
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction
  • Maintenance-free – no moving parts
  • Convenient device wiring – separate connection compartment
  • Safe operation – no need to open the device due to display with touch control, background lighting
  • Integrated verification – Heartbeat TechnologyTM
Measuring principle

Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field.

Ue: Induced voltage
B: Magnetic induction (magnetic field)
L: Electrode spacing
I: Current
v: Flow velocity

In the electromagnetic measuring principle, the flowing medium is the moving conductor. The voltage induced (U e ) is proportional to the flow velocity (v) and is supplied to the amplifier by means of two measuring electrodes. The flow volume (Q) is calculated via the pipe cross-section (A). The DC magnetic field is created through a switched direct current of alternating polarity.

Formulae for calculation

Induced voltage Ue = B · L · v
Volume flow Q = A · v

Measuring system

The device consists of a transmitter and a sensor.

The device is available as a compact version:
The transmitter and sensor form a mechanical unit.

Measuring principle

Electromagnetic

Product headline

Flowmeter for smallest flow rates with genuine loop-powered technology. Dedicated to the measurement of the smallest flow quantities.

Sensor features

Flexible installation concept – numerous process connections. Energy-saving flow measurement – no pressure loss due to cross-section constriction. Maintenance-free – no moving parts. Liner made of PFA. Sensor housing made of stainless steel.

Transmitter features

Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop‐powered technology. Robust dual‐compartment housing.

Nominal diameter range

DN 2 to 25 (¹⁄₁₂ to 1")

Wetted materials

Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum

Measured variables

Volume flow, mass flow

Max. measurement error

Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)

Measuring range

0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min)

Max. process pressure

PN 40, Class 150, 20K

Medium temperature range

–20 to +150 °C (–4 to +302 °F)

Ambient temperature range

–40 to +60 °C (–40 to +140 °F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

AlSi10Mg, coated

Degree of protection

IP66/67, type 4X enclosure

Display/Operation

4‐line backlit display with touch control (operation from outside)

Configuration via local display and operating tools possible

Remote display available

Outputs

4‐20 mA HART (passive)

Pulse/frequency/switch output (passive)

Inputs

None

Digital communication

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)

Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN

Product safety

CE, C-Tick

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)

Pressure approvals and certificates

CRN

Material certificates

3.1 material

Export Info
Made inFrance
Harmonized Tariff Code (HTC)9026107000

  • FLOW > BATCH CONTROLLERS
    RA33-AA1-AA EH RA33 Batch Controller for flow and control output signals. 1 4-20mA or Pulse Flow input, 1 RTD or 4-20mA Temperature input, 1 4-20mA Density input, 2 digital inputs, 2 open collector and 2 relay outputs. Temperature and density compensation function. I ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HAZARDOUS LOCATIONS :    18 Items found.
6BABL1-AADAAAASAGA1G
(144)

ENDRESS+HAUSER  6BABL1-AADAAAASAGA1G

EH Proline t-mass B 150 Thermal Mass Flowmeter for measurement on large pipelines or rectangular ventilation ducts. 20 to 720 000 kg/h measuring range. DN80 Nominal Diameter. 18-30VDC. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display with push buttons. ATEX, IECEx and 0cCSAus approvals.

DTI200-A16A1A
(148)

ENDRESS+HAUSER  DTI200-A16A1A

EH Magphant Electromagnetic compact Flowmeter and Limit Switch for repeatable flow monitoring. 0...56'550 m3/h measuring range. DN15 to DN2000 Nominal Diameter. IP66 NEMA 4X Enclosure. Includes 4-20mA and relay outputs. FM and CSA approvals.

5H1B02-AADBAAA00000A
(139)

ENDRESS+HAUSER  5H1B02-AADBAAA00000A

EH Proline Promag H 100 Electromagnetic Flowmeter for the smallest flow rates with ultra compact transmitter. 0.06 dm3/min to 600 m3/h measuring range. DN 2 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24 VDC. Includes 4-20ma and switch outputs. Optional 4 line backlit display and Modbus RS485 communication. ATEX, IECEx, cCSAus, INMETRO and EAC approvals.

5H3B02-AAIBAAAAAA00000AA1
(415)

ENDRESS+HAUSER  5H3B02-AAIBAAAAAA00000AA1

EH Proline Promag H 300 Electromagnetic Flowmeter with compact transmitter for hygienic applications. 0.06 dm³/min to 600 m³/h measuring range. DN 02 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) or stainless steel housing. Includes 4-20ma, pulse/frequency/switch and double pulse outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

7F2C15-AAAACAAAAAAAASKA1
(143)

ENDRESS+HAUSER  7F2C15-AAAACAAAAAAAASKA1

EH Proline Prowirl F 200 Vortex Flowmeter with wet steam detection for heavy duty applications. Compact or remote version. 0.16 to 2412 m3/h measuring range. DN15 Nominal Diameter. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display. ATEX, IECEx and cCSAus approvals.

5E1B80-AADBAAA8A1KGA
(413)

ENDRESS+HAUSER  5E1B80-AADBAAA8A1KGA

EH Proline Promag E 100 Electromagnetic Flowmeter with ultra-compact transmitter. 4 dm³/min to 9600 m³/h measuring range. DN 80 Nominal Diameter. 24VDC. IP66. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

5W3B25-AAEIBAAAAAAUA1KGAA1
(409)

ENDRESS+HAUSER  5W3B25-AAEIBAAAAAAUA1KGAA1

EH Proline Promag W 300 Electromagnetic Flowmeter with compact transmitter for water and wastewater applications. 9 dm³/min to 162 000 m³/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX and cCSAus approvals.

5H5B15-AAIBAAAAFAAAAA00000AA1
(416)

ENDRESS+HAUSER  5H5B15-AAIBAAAAFAAAAA00000AA1

EH Proline Promag H 500 Electromagnetic Flowmeter for hygienic applications as remote version with up to 4 I/Os. 0.06 dm³/min to 600 m³/h measuring range. DN 15 (1/2") Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, pulse/frequency/switch and relay outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

5P3B15-AAIBAAAAAAEA1KGAA1
(407)

ENDRESS+HAUSER  5P3B15-AAIBAAAAAAEA1KGAA1

EH Proline Promag P 300 Electromagnetic Flowmeter for highest medium temperatures with compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. PTFE Liner. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

9B2B80-AAAACA1W0W1
(141)

ENDRESS+HAUSER  9B2B80-AAAACA1W0W1

EH Proline Prosonic Flow B 200 Ultrasonic Flowmeter for biogas measurement with loop-powered technology. 1 to 30 m/s measuring range. DN 80 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display. ATEX, IECEx, cCSAus, NEPSI and INMETRO approvals.

8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8FF08-AG15AABAA10N
(145)

ENDRESS+HAUSER  8FF08-AG15AABAA10N

EH CNGmass Coriolis Flowmeter with the highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8F1B08-AADBAAASAAASA
(140)

ENDRESS+HAUSER  8F1B08-AADBAAASAAASA

EH Proline Promass F 100 Coriolis Flowmeter with premium accuracy, robustness and ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

8P1B15-AADBAAABBAAWA
(411)

ENDRESS+HAUSER  8P1B15-AADBAAABBAAWA

EH Proline Promass P 100 Coriolis Flowmeter with ultra-compact transmitter for applications in sterile environments. 0 to 70000 kg/h measuring range. DN 08 Nominal Diameter. 24VDC. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, pulse and frequency outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

83E50-AAASAAAAAAAA
(189)

ENDRESS+HAUSER  83E50-AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

8F3B25-AAIBAAAAAASAAASAA1
(408)

ENDRESS+HAUSER  8F3B25-AAIBAAAAAASAAASAA1

EH Proline Promass F 300 Coriolis Flowmeter with highly accurate sensor and robust compact transmitter. 0 to 2 200000 kg/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

8DF08-AG15AAAAA70M
(146)

ENDRESS+HAUSER  8DF08-AG15AAAAA70M

EH CNGmass DCI Coriolis Flowmeter. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.