Process Control Instruments, Field Devices and Industrial Automation
SKU# (365)

ENDRESS+HAUSER  CYH112-AA11A11A1




ENDRESS+HAUSER CYH112-AA11A11A1 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Flexdip CYH112 Modular holder system for water and wastewater sensors and assemblies. Up to 6 bar pressure. Works for floor, wall or rail fixings. UV photometric measuring principle.

Part# with Options:        CYH112-AA11A11A1
Price with Options:        Please Email us your request for quote   

Options:    

Mounting of post
(1) Mounting of post for EH CYH112
Post (vertical 40mm)
(2) Post (vertical 40mm) for EH CYH112
Traverse Mounting
(3) Traverse Mounting for EH CYH112
Traverse (horizontal 40mm)
(4) Traverse (horizontal 40mm) for EH CYH112
Connection Immersion Pipe
(5) Connection Immersion Pipe for EH CYH112

  Availability 3 Days  ]

Holder system for water and wastewater assemblies

Application
  • Water treatment
  • Wastewater treatment
  • Plant design

CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks.

Sensors installed in assemblies get in this way directly immersed in the medium - the in-situ measurement allows direct and prompt measured values without detour via sampler.

A very flexible holder system is needed to be able to install the assembly at the right point.

The holder system CYH112 works for nearly any type of fixing - fixing on the floor, wall or directly on a rail.

Your benefits
  • Simple, cost-effective and flexible expandable
  • Modular construction system
  • Installation of the holder system on the floor, on the wall, on the rail
  • Installation of the sensor on a cantilever arm with chain, fixed immersion pipe or free swinging installation
  • Float-lever version for varying levels
  • Holder adjustable in height, position and orientation
  • Expandable, easy to retrofit
  • Stainless steel or plastic version
  • Captive screw joints
  • Easy to install and to maintain

Measuring principle

UV photometric

Application

Water treatment
Wastewater treatment
Plant design
Open channels
Basins
Open tanks and process vats
Fluctuating water levels

Installation

CYH112 is a modular holder system for sensors and assemblies
in open basins, channels and tanks.

Characteristic

simple and easy installation
universal and flexible

Design

The holder system CYH112 works for nearly any type of fixing
- fixing on the floor, wall or directly on a rail.

Material

stainless steel and plastic

Process temperature

-20 to +60 C
-4 to 140 F


  • CONDUCTIVITY ANALIZERS > ASSEMBLY
    CLA111-00A EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CYA112-AA11A1AA EH Flexdip CYA112 Immersion Modular assembly for water and wastewater. UV photometric measuring principle. Stainless steel or PVC versions. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ASSEMBLY :    31 Items found.
CPA450-0B110
(281)

ENDRESS+HAUSER  CPA450-0B110

EH Cleanfit CPA450 Manual retractable assembly for water & wastewater, chemical, pulp & paper and power industries. Accepts 12mm DO, pH and ORP sensors. DN32 Process Connection.

CYA680-1A1C1
(397)

ENDRESS+HAUSER  CYA680-1A1C1

EH CYA680 flow assembly for pH and conductivity measurement in pipelines of hygienic and sterile applications. Glass electrode measuring principle. Pipe mounting. 0,25" to 2" Clamp Connection.

COA451-A1A
(310)

ENDRESS+HAUSER  COA451-A1A

EH Cleanfit COA451 manually operated retractable assembly for Dissolved Oxygen sensors. Includes stop bolt, O-ring seals and a ball valve. Stainless Steel Holder.

CUA451-A1A
(316)

ENDRESS+HAUSER  CUA451-A1A

EH Cleanfit CUA451 Turbidity Retractable assembly for water and wastewater applications with CUS31/CUS41/CUS51D/CUS52D sensors. Manually operated. Includes Stop bolt, O-ring seals and ball valve. DN50 Process Connection.

CPA451-A3A
(280)

ENDRESS+HAUSER  CPA451-A3A

EH Cleanfit CPA451 Manual retractable assembly for water, wastewater and process media. Accepts pH and ORP sensors (CPF81/82). NPT 3/4" Sensor Connection. DN50 Process Connection.

CSA420-AA1A1A1A1A
(392)

ENDRESS+HAUSER  CSA420-AA1A1A1A1A

EH Samplefit CSA420 Sampling assembly for taking samples in pressurized pipes. 10, 30 or 50 ml fixed sample volume. 85mm immersion depth. DN50 Process Connection. Up to 90psi max pressure.

CPA474-A3A1A1G7
(277)

ENDRESS+HAUSER  CPA474-A3A1A1G7

EH Cleanfit CPA474 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50 Process Connection.

CPA875-AAC1E1CA1A1A
(276)

ENDRESS+HAUSER  CPA875-AAC1E1CA1A1A

EH Cleanfit CPA875 Manual or automatic process retractable assembly for sterile and hygienic applications. Accepts standard (12mm) pH, ORP, oxygen and NIR sensors. DN25/50/65/100 Process Connection.

CPA871-AACA1ACB1C
(275)

ENDRESS+HAUSER  CPA871-AACA1ACB1C

EH Cleanfit CPA871 Manual or automatic process retractable compact assembly for the water, wastewater and chemical industries. Suitable for vessels and pipes. Accepts standard 12mm pH and ORP sensors. NPT 1 1/2 or DN40/50/80 Process Connection.

CPA473-A3A1A1A7
(278)

ENDRESS+HAUSER  CPA473-A3A1A1A7

EH Cleanfit CPA473 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50/65 Process Connection.

CPA472D-A4A1C1D1
(279)

ENDRESS+HAUSER  CPA472D-A4A1C1D1

EH Cleanfit CPA472D Manual or automatic process retractable heavy-duty assembly for chemical and power industries. Accepts pH and ORP electrodes. DN50/80 Process Connection.

Page: 1 | 2 | All