CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

CPS471-2ESB1
(385)

ENDRESS+HAUSER  CPS471-2ESB1

EH Tophit CPS471 analog pH sensor with ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

TST90-1U1S31S2E
(343)

ENDRESS+HAUSER  TST90-1U1S31S2E

EH Omnigrad TST90 Modular RTD thermometer and insert for high-precision measurement of temperature differences with matched sensor pairs. G1/2" Process Connection. PT100 Temperature Sensor. 316Ti Material Neck.

CPS171D-AA7NTP2
(353)

ENDRESS+HAUSER  CPS171D-AA7NTP2

EH Memosens CPS171D Digital Sensor with glass electrode for pH measurement on hygienic and sterile applications (bioreactors and fermenters). 0 - 14 pH measurement range. 0 to 102 psi process pressure. NTC 30k temperature sensor. ATEX, CSA, FM and IECEx approvals.

FDU91F-RF1A
(213)

ENDRESS+HAUSER  FDU91F-RF1A

EH Prosonic FDU91F Ultrasonic Time-of-Flight level and flow hygienic sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-20mA HART communication. 316L main wetted parts. G, NPT, DN80 or DN100 Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

PMD55-AA22AA27BGBHA4A1A
(410)

ENDRESS+HAUSER  PMD55-AA22AA27BGBHA4A1A

EH Deltabar PMD55 differential pressure transmitter with metal sensor for measurement of pressure differences. 10mbar to 40bar measuring range. NPT1/4-18 Process Connection. ATEX, FM, CSA and IECEx Approvals.

FMU41-SNB1A2
(120)

ENDRESS+HAUSER  FMU41-SNB1A2

EH Prosonic FMU41 Ultrasonic Transmitter for non-contact Level Measurement. HART. PROFIBUS PA. Multilingual Plain Text Display. Easy remote operation. Suitable for explosion hazardous areas. FM Approval.

FQR56-AAAAAVEA1
(267)

ENDRESS+HAUSER  FQR56-AAAAAVEA1

EH Soliwave FQR56 Microwave barrier emitter for non-contact point level detection in bulk solids. Up to 100m measurement range. Suitable as level limit switch. ATEX, CSA and IECEx Approvals.

FTG20-AA14A1AA
(235)

ENDRESS+HAUSER  FTG20-AA14A1AA

EH Gammapilot FTG20 Radiometric Geiger-Mueller counter for non-contact point level detection with separate transmitter. Highest sensitivity. DPDT Relay. 4-20mA HART communication. ATEX, CSA and IECEx Approvals.

CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
FMR56-AAAAAABNXR0
(195)

ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

FTL81-AASAABA1ABJVBJ
(245)

ENDRESS+HAUSER  FTL81-AASAABA1ABJVBJ

EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals.

FMR52-AAAAAABOCFK
(193)

ENDRESS+HAUSER  FMR52-AAAAAABOCFK

EH Micropilot FMR52 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids. DN50 to DN150 Process Connection. 2-wire or 4-wire HART communication. PTFE-filled and flush-mounted horn antenna. FM and CSA approvals.

5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

CSP44-AA1A1
(342)

ENDRESS+HAUSER  CSP44-AA1A1

EH Liquiport 2010 CSP44 Fully automatic portable sampler for liquids. Integrated multi-parameter controller with 2 measuring channels and optional digital Memosens technology. 2 0/4-20 mA analog inputs/outputs and 2 binary inputs/outputs. Plastic LDDPE Cabinet.

CAT820-AAE11A2A100A
(335)

ENDRESS+HAUSER  CAT820-AAE11A2A100A

EH Liquiline System CAT820 automatic in-situ filtration system for control of sample conditioning in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval.

8F3B25-AAIBAAAAAASAAASAA1
(408)

ENDRESS+HAUSER  8F3B25-AAIBAAAAAASAAASAA1

EH Proline Promass F 300 Coriolis Flowmeter with highly accurate sensor and robust compact transmitter. 0 to 2 200000 kg/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

CAS51D-AAA1A2
(338)

ENDRESS+HAUSER  CAS51D-AAA1A2

EH Viomax CAS51D digital memosens photometric sensor for optical nitrate or SAC measurement in water, wastewater and utilities. Self-cleaning functionality. IP68.