Process Control Instruments, Field Devices and Industrial Automation
SKU# (146)

ENDRESS+HAUSER  8DF08-AG15AAAAA70M

$16,226.38     Availability: 3 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



ENDRESS+HAUSER 8DF08-AG15AAAAA70M (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH CNGmass DCI Coriolis Flowmeter. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.

Part# with Options:        8DF08-AG15AAAAA70M
Price with Options:        16,226.38

Options:    

Measure Tube Material
(1) Measure Tube Material for EH CNGmass & LPGmass
Additional Test
(2) Additional Test for EH CNGmass
Calibration
(3) Calibration for EH CNGmass DCI
Approval
(4) Approval for EH CNGmass DCI
Housing
(5) Housing for EH CNGmass DCI
Cable Entry
(6) Cable Entry for EH CNGmass DCI
Power Supply & Display
(7) Power Supply & Display for EH CNGmass
Custody Transfer Approval
(8) Custody Transfer Approval for EH CNGmass DCI
Output/Input
(9) Output/Input for EH CNGmass DCI

  Availability 3 Weeks  ]

Area of Application
  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • Accurate measurement of compressed natural gas (CNG) in high-pressure refueling applications
Device properties
  • Flow rates up to 150 kg/min (330 lb/min)
  • Process pressure up to 350 bar (5080 psi)
  • Rupture disc available
  • Device in compact or remote version
  • Flexible outputs and Modbus RS485
  • Transmitter for custody transfer
Your benefits
  • Excellent operational safety - reliable under extreme process conditions
  • Fewer process measuring points multivariable measurement (flow, density, temperature)
  • Space-saving installation no in/outlet run needs
  • High flexibility in system integration - wide range of communication interfaces
  • Fast commissioning pre-configured devices
  • Automatic recovery of data for servicing
Measuring principle

The measuring principle is based on the controlled generation of Coriolis forces. These forces are always present when both translational and rotational movements are superimposed.

The amplitude of the Coriolis force depends on the moving mass Δm, its velocity v in the system, and thus on the mass flow. Instead of a constant angular velocity ω, oscillation occurs.

In the sensor, two parallel measuring tubes containing flowing fluid oscillate in antiphase, acting like a tuning fork. The Coriolis forces produced at the measuring tubes cause a phase shift in the tube oscillations (see illustration):

  • At zero flow, in other words when the fluid is at a standstill, the tubes oscillate in phase (1).two
  • Mass flow causes deceleration of the tube oscillation at the inlet (2) and acceleration at the outlet (3).

The phase difference (A-B) increases with increasing mass flow. Electrodynamic sensors register the tube oscillations at the inlet and outlet. System balance is ensured by the antiphase oscillation of the two measuring tubes. The measuring principle works independently of temperature, pressure, viscosity, conductivity and flow profile.

Measuring Principle Coriolis
Product headline The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
Sensor features Excellent operational safety reliable under extreme process conditions. Fewer process measuring points multivariable measurement (flow, density, temp). Space‐saving installation no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
Transmitter features High flexibility in system integration wide range of communication interfaces. Fast commissioning preconfigured devices. Automatic recovery of data for servicing. Device in compact or remote version. Flexible outputs and Modbus RS485.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measured error Mass flow: 0.5 % of batch
Measuring range 0 to 150 kg/min (0 to 330 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range 50 to +150 C (58 to +302 F)
Ambient temperature range Standard: 20 to +60 C (4 to +140 F)
Option: 40 to +60 C (40 to +140 F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive), phase‐shifted pulse
Relay
Inputs 1 modular input: status
Digital communication HART, Modbus RS485
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer
CRN
Export Info
Harmonized Tariff Code (HTC)9026107000

  • FLOW > BATCH CONTROLLERS
    RA33-AA1-AA EH RA33 Batch Controller for flow and control output signals. 1 4-20mA or Pulse Flow input, 1 RTD or 4-20mA Temperature input, 1 4-20mA Density input, 2 digital inputs, 2 open collector and 2 relay outputs. Temperature and density compensation function. I ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CORIOLIS TRANSMITTERS > HAZARDOUS LOCATIONS :    16 Items found.
6BABL1-AADAAAASAGA1G
(144)

ENDRESS+HAUSER  6BABL1-AADAAAASAGA1G

EH Proline t-mass B 150 Thermal Mass Flowmeter for measurement on large pipelines or rectangular ventilation ducts. 20 to 720 000 kg/h measuring range. DN80 Nominal Diameter. 18-30VDC. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display with push buttons. ATEX, IECEx and 0cCSAus approvals.

Configure

$1,421.41 
DTI200-A16A1A
(148)

ENDRESS+HAUSER  DTI200-A16A1A

EH Magphant Electromagnetic compact Flowmeter and Limit Switch for repeatable flow monitoring. 0...56'550 m3/h measuring range. DN15 to DN2000 Nominal Diameter. IP66 NEMA 4X Enclosure. Includes 4-20mA and relay outputs. FM and CSA approvals.

Configure

$1,631.37 
5H1B02-AADBAAA00000A
(139)

ENDRESS+HAUSER  5H1B02-AADBAAA00000A

EH Proline Promag H 100 Electromagnetic Flowmeter for the smallest flow rates with ultra compact transmitter. 0.06 dm3/min to 600 m3/h measuring range. DN 2 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24 VDC. Includes 4-20ma and switch outputs. Optional 4 line backlit display and Modbus RS485 communication. ATEX, IECEx, cCSAus, INMETRO and EAC approvals.

Configure

$2,780.88 
7F2C15-AAAACAAAAAAAASKA1
(143)

ENDRESS+HAUSER  7F2C15-AAAACAAAAAAAASKA1

EH Proline Prowirl F 200 Vortex Flowmeter with wet steam detection for heavy duty applications. Compact or remote version. 0.16 to 2412 m3/h measuring range. DN15 Nominal Diameter. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display. ATEX, IECEx and cCSAus approvals.

Configure

$3,094.96 
5H2B15-AAAACA00000A
(414)

ENDRESS+HAUSER  5H2B15-AAAACA00000A

EH Proline Promag H 200 Electromagnetic Flowmeter with loop-powered technology for smallest flow rates. 0.06 dm/min to 300 m/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

Configure

$3,501.57 
5E1B80-AADBAAA8A1KGA
(413)

ENDRESS+HAUSER  5E1B80-AADBAAA8A1KGA

EH Proline Promag E 100 Electromagnetic Flowmeter with ultra-compact transmitter. 4 dm/min to 9600 m/h measuring range. DN 80 Nominal Diameter. 24VDC. IP66. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

Configure

$3,669.24 
5W3B25-AAEIBAAAAAAUA1KGAA1
(409)

ENDRESS+HAUSER  5W3B25-AAEIBAAAAAAUA1KGAA1

EH Proline Promag W 300 Electromagnetic Flowmeter with compact transmitter for water and wastewater applications. 9 dm/min to 162 000 m/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX and cCSAus approvals.

Configure

$3,794.27 
5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

Configure

$3,965.44 
5P3B15-AAIBAAAAAAEA1KGAA1
(407)

ENDRESS+HAUSER  5P3B15-AAIBAAAAAAEA1KGAA1

EH Proline Promag P 300 Electromagnetic Flowmeter for highest medium temperatures with compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. PTFE Liner. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

Configure

$4,070.61 
9B2B80-AAAACA1W0W1
(141)

ENDRESS+HAUSER  9B2B80-AAAACA1W0W1

EH Proline Prosonic Flow B 200 Ultrasonic Flowmeter for biogas measurement with loop-powered technology. 1 to 30 m/s measuring range. DN 80 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display. ATEX, IECEx, cCSAus, NEPSI and INMETRO approvals.

Configure

$6,150.63 
8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

Configure

$7,658.78 
8FF08-AG15AABAA10N
(145)

ENDRESS+HAUSER  8FF08-AG15AABAA10N

EH CNGmass Coriolis Flowmeter with the highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

Configure

$7,803.71 
8F1B08-AADBAAASAAASA
(140)

ENDRESS+HAUSER  8F1B08-AADBAAASAAASA

EH Proline Promass F 100 Coriolis Flowmeter with premium accuracy, robustness and ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

Configure

$8,332.70 
8P1B15-AADBAAABBAAWA
(411)

ENDRESS+HAUSER  8P1B15-AADBAAABBAAWA

EH Proline Promass P 100 Coriolis Flowmeter with ultra-compact transmitter for applications in sterile environments. 0 to 70000 kg/h measuring range. DN 08 Nominal Diameter. 24VDC. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, pulse and frequency outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

Configure

$9,122.35 
83E50-AAASAAAAAAAA
(189)

ENDRESS+HAUSER  83E50-AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

Configure

$9,658.01 
8F3B25-AAIBAAAAAASAAASAA1
(408)

ENDRESS+HAUSER  8F3B25-AAIBAAAAAASAAASAA1

EH Proline Promass F 300 Coriolis Flowmeter with highly accurate sensor and robust compact transmitter. 0 to 2 200000 kg/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

Configure

$10,479.61