EH Waterpilot FMX21 Hydrostatic Level probe with ceramic measuring cell. Reliable and robust. Automatic density compensation. 100 mbar to 20 bar measuring range. 10.5 to 35 VDC. Suspension clamp process connections. 4-20mA and HART communications. ATEX, FM, CSA, CSA C/US and IECEx Approvals.

Part# with Options:        FMX21-AA111CGB20A
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH Waterpilot FMX21
Output
(2) Output for EH Waterpilot FMX21
Probe Tube
(3) Probe Tube for EH Waterpilot FMX21
Sensor Range
(4) Sensor Range for EH Waterpilot FMX21
Reference Accuracy
(5) Reference Accuracy for EH Waterpilot FMX21
Calibration & Unit
(6) Calibration & Unit for EH Waterpilot FMX21
Probe Connection
(7) Probe Connection for EH Waterpilot FMX21
Seal
(8) Seal for EH Waterpilot FMX21

  Availability 5 Days  ]

Application

The Waterpilot FMX21 is a pressure sensor for hydrostatic level measurement.

Endress+Hauser offers three different versions of the device:

  • FMX21 with a stainless steel housing, external diameter of 22 mm (0.87 in): This version is excellently suited to drinking water applications and for use in bore holes and wells with small diameters
  • FMX21 with a stainless steel housing, external diameter of 42 mm (1.65 in): Heavy-duty version and easy to clean thanks to flush-mounted process isolating diaphragm, ideally suited to wastewater and wastewater treatment plants
  • FMX21 with plastic insulation, external diameter of 29 mm (1.14 in): Robust version for use in salt water and excellently suited to applications on ships (e.g. ballast water tanks)
Your benefits
  • High resistance to overload
  • High-precision, robust ceramic measuring cell with long-term stability
  • Climate proofed sensor thanks to completely potted electronics and 2-filter pressure compensation system
  • Simultaneous measurement of level and temperature with optionally integrated Pt100 temperature sensor
  • Accuracy
    • Standard reference accuracy 0.2 %
    • PLATINUM version 0.1 %
  • Automatic density compensation to increase accuracy
  • Usage in drinking water: KTW, NSF, ACS
  • Approvals: ATEX, FM, CSA
  • Marine approvals: GL, ABS, BV, DNV
  • Extensive range of accessories provides complete measuring point solutions
Measuring Principle

The ceramic measuring cell is a dry measuring cell i.e. the pressure acts directly on the robust, ceramic process isolating diaphragm of the Waterpilot FMX21. Changes in air pressure are guided via a pressure compensation tube through the extension cable to the rear of the ceramic process isolating diaphragm and are compensated for. A pressure-dependent change in capacitance, caused by the movement of the process isolating diaphragm, is measured at the electrodes of the ceramic carrier. The electronics unit then converts this to a signal that is proportional to the pressure and linear to the level.

Measuring Principle Hydrostatic
Characteristic / Application Compact probe with ceramic cell for hydrostatic level measurement,
Diameter = 22 mm: General applications, Fresh water
Diameter = 42 mm: Waste water applications
Diameter = 29 mm: Salt water applications

Specialities Automatic density compensation
Version w/o metal parts in contact to process
Supply / Communication 10.5 ...35 VDC

Accuracy 0.2%
0.1% (optional)
Long term stability 0.1% of URL/year
Ambient temperature -10C...70C
(14F...158F)
Diameter 29 mm (1.14"):
0C...50C
(32F...122F)
Process temperature -10C...70C
(14F...158F)
Diameter 29 mm (1.14"): 0C...50C
(32F...122F)
Pressure measuring range 100 mbar...20 bar
(1.5 psi...300 psi)
Main wetted parts Diameter 22 mm and 42 mm: Seal, 316L, Ceramic
Diameter 29 mm: Seal, PPS, Polyolefin, Ceramic
Extension cable: PE, PUR, FEP
Process connection Suspension clamp
Cable mounting screws
Max. measurement distance 200 m H2O
(656 ft H2O)
Communication 4...20 mA
4...20 mA HART

Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI

Marine approval GL/ ABS/ BV/ DNV
Drinking water approvals KTW/ NSF/ ACS
Options Absolute measuring cell
Integrated temperature sensor Pt100, 4-wire
customer specific adjustment
customer specific cable marking

Application limits Measuring cell: ceramics


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CERAMIC TRANSMITTERS > HAZARDOUS LOCATIONS :    47 Items found.
FTW31-A1A2EA0A
(264)

ENDRESS+HAUSER  FTW31-A1A2EA0A

EH Liquipoint FTW31 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTL325N-O1A1
(250)

ENDRESS+HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

FTW325-A2A1A
(266)

ENDRESS+HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

FMI21-A1D1A1
(233)

ENDRESS+HAUSER  FMI21-A1D1A1

EH Liquicap FMI21 Capacitive rod probe for continuos level measurement in conductive liquids. 316L, 1.4404 or PP wetted parts. NPT 1 1/2 or G 1 1/2 Process Connection. ATEX and CSA Approvals.

FTC262-AA32B1
(232)

ENDRESS+HAUSER  FTC262-AA32B1

EH Minicap FTC262 Capacitive rope probe for point level detection in light bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1 1/2 or R 1 1/2 Process Connection. PNP transistor and relay outputs. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

11375Z-RXG1A5A5
(257)

ENDRESS+HAUSER  11375Z-RXG1A5A5

EH 11375Z One rod probe for point level detection of conductive liquids with higher temperatures. 316Ti Rod. PTFE Partial Insulaion. G 1/2 Process Connection. Relay Communication. ATEX Approval.

11362Z-R1AA4A11CA
(259)

ENDRESS+HAUSER  11362Z-R1AA4A11CA

EH 11362Z Double rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FDU90-RG1AA
(211)

ENDRESS+HAUSER  FDU90-RG1AA

EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTC325-A2A31
(231)

ENDRESS+HAUSER  FTC325-A2A31

EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

FTM20-AA22A
(254)

ENDRESS+HAUSER  FTM20-AA22A

EH Soliphant FTM20 Vibronic Compact Point level limit switch for bulk solids in dust or hazardous areas. 1 1/4" NPT, 1 1/2" NPT or R Process Connection. ATEX, FM, CSA and IECEx approvals.

FDU91-RG1AA
(212)

ENDRESS+HAUSER  FDU91-RG1AA

EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTL50-AGE2AA1E4A
(237)

ENDRESS+HAUSER  FTL50-AGE2AA1E4A

EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11961Z-RCG1AB5
(256)

ENDRESS+HAUSER  11961Z-RCG1AB5

EH 11961Z One rod probe for point level detection of conductive liquids steam boilers. Highly resistant. 316Ti Rod. G 1/2 Process Connection. Relay Communication. ATEX Approval.

FTL51-AGE2DB1E4A
(241)

ENDRESS+HAUSER  FTL51-AGE2DB1E4A

EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11363Z-R1AA4A111CA
(260)

ENDRESS+HAUSER  11363Z-R1AA4A111CA

EH 11363Z Triple rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FTM21-AM622A
(255)

ENDRESS+HAUSER  FTM21-AM622A

EH Soliphant FTM21 Vibronic Compact Point level limit switch with extension tube for bulk solids in dust or hazardous areas. Stainless Steel Housing (316L). 1 1/4" NPT or 1 1/2" NPT Process Connection. ATEX, FM, CSA and IECEx approvals.

FTL325P-O1A1
(248)

ENDRESS+HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.