Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CLS30-D1C4A (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Condumax W CLS30 2-electrode conductivity sensor for waste water and concentrate applications. Pt100 temperature sensor. 0,1-200,0mS/cm measuring range. 10ft cable connection. PP/PTFE Material. DN25 Process connection. IP65. ATEX and qualitity certifications.

Part# with Options:        CLS30-D1C4A
Price with Options:        Please Email us your request for quote   

Options:    

Process Connection
(1) Process Connection for EH Condumax W CLS30

  Availability 4 Days  ]

Application

Measurements in media of high or medium conductivities:

  • Process water
  • Wastewater treatment
  • Concentrate monitoring

The cell constant k of the sensor is 10 cm 1 . The measuring range reaches from 0.1 mS/cm to 200 mS/cm.

Sensors with temperature sensors are used together with conductivity transmitters equipped with automatic temperature compensation:

  • Mycom S CLM153
  • Liquisys M CLM223/253
  • Liquiline M CM42
Your benefits
  • Various designs guarantee optimum adaptation to the process conditions and
  • methods of installation
  • Installation in pipes or flow chambers
  • High chemical, thermal and mechanical stability
  • Compact design
  • Quality certificate with statement of the individual cell constant
Measuring Principle

The conductivity of liquids is measured with the following measurement setup: Two electrodes are immersed in the medium. An AC voltage is applied to these electrodes which generates a current in the medium.

The electric resistance or its reciprocal value, the conductance G, is calculated according to Ohms law. The specific conductivity κ is determined using the cell constant k that is dependent on the sensor geometry.

Measuring Principle Conductive
Application Water, concentrate
Characteristic 2-electrode system for controlling of industrial water or concentrates.
Measurement range k=10: 0,1 mS/cm - 200 mS/cm
Measuring principle Conductiv conductivity cell with graphite electrodes.
Design Punctual arranged graphite electrodes under PTFE protective cover.
Material Cell shaft: PTFE / PP
Electrode: graphite
Temperature sensor: titanium
Dimension Diameter: 22 mm
(0.85 inch)
Lenghth: 105 mm or 120 mm
(4.09 inch or 4.68 inch)
Process temperature max. 125C
(max. 257F)
Process pressure max. 16 bar
(max. 232 psi)
temperature sensor Pt100
Ex certification ATEX
Connection Process connection: G1", DN25,
fixed cable connection.
Ingres protection IP65
Additional Certifications Quality certification

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HAZARDOUS LOCATIONS :    41 Items found.
CPS41-1AB2SSA
(379)

ENDRESS+HAUSER  CPS41-1AB2SSA

EH Ceraliquid CPS41 analog pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS19-A1A1D
(370)

ENDRESS+HAUSER  CLS19-A1A1D

EH Condumax CLS19 2-electrode Analog conductive conductivity sensor for pure and ultrapure water applications. NPT 1/2" Process Connection. IP65. ATEX Approval.

CPS42-0PB2SSA
(381)

ENDRESS+HAUSER  CPS42-0PB2SSA

EH Ceraliquid CPS42 analog ORP glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12-0NA2ESA
(376)

ENDRESS+HAUSER  CPS12-0NA2ESA

EH Orbisint CPS12 Analog ORP glass electrode sensor for standard applications in process and environmental technology. PTFE diaphragm. -1500 mV to +1500 mV measurement range. 230 psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12D-7NA2C
(377)

ENDRESS+HAUSER  CPS12D-7NA2C

EH Orbisint CPS12D Digital ORP glass electrode Memosens sensor for standard applications in process and environmental technology. Teflon diaphragm. -1500 mV to +1500 mV measurement range. 16bar max pressure. Pt1000 Temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS71D-7TB2C
(363)

ENDRESS+HAUSER  CPS71D-7TB2C

EH Ceragel CPS71D Digital pH Memosens glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. NTC 30k temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS42D-7PB4AC
(382)

ENDRESS+HAUSER  CPS42D-7PB4AC

EH Ceraliquid CPS42D digital ORP Memosens glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS41D-7AB4AC
(380)

ENDRESS+HAUSER  CPS41D-7AB4AC

EH Ceraliquid CPS41D Memosens digital pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. NTC 30k Temperature Sensor. IP68. ATEX, FM and CSA approvals.

CPS471-2ESB1
(385)

ENDRESS+HAUSER  CPS471-2ESB1

EH Tophit CPS471 analog pH sensor with ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS171D-AA7NTP2
(353)

ENDRESS+HAUSER  CPS171D-AA7NTP2

EH Memosens CPS171D Digital Sensor with glass electrode for pH measurement on hygienic and sterile applications (bioreactors and fermenters). 0 - 14 pH measurement range. 0 to 102 psi process pressure. NTC 30k temperature sensor. ATEX, CSA, FM and IECEx approvals.

CPS491-2ESB2
(387)

ENDRESS+HAUSER  CPS491-2ESB2

EH Tophit CPS491 analog pH sensor with ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS471D-721C
(386)

ENDRESS+HAUSER  CPS471D-721C

EH Tophit CPS471D digital pH sensor with Memosens ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. Pt1000 temperatura sensor. IP68. ATEX, FM and CSA approvals.

CPS72D-7PT2C
(391)

ENDRESS+HAUSER  CPS72D-7PT2C

EH Ceragel CPS72D Digital ORP Memosens glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68. ATEX, FM and CSA approval.

CPS491D-722C
(388)

ENDRESS+HAUSER  CPS491D-722C

EH Tophit CPS4901D digital pH sensor with Memosens ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. Pt1000 temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS441-2ESC1
(383)

ENDRESS+HAUSER  CPS441-2ESC1

EH Tophit CPS441 analog pH sensor with ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS441D-72B1C
(384)

ENDRESS+HAUSER  CPS441D-72B1C

EH Tophit CPS441D Digital pH sensor with Memosens ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

Page: 1 | 2 | 3 | All