Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CCA250-A0 (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing.

Part# with Options:        CCA250-A0
Price with Options:        Please Email us your request for quote   

Options:    

Process Connection & Adaptor
(1) Process Connection & Adaptor for EH CCA250
Proximity Switch
(2) Proximity Switch for EH CCA250

  Availability 5 Days  ]

Application

The flow assembly CCA250 has been specially designed to hold the chlorine resp. chlorine dioxide sensors CCS120, CCS140, CCS141, CCS240, CCS241 or CCS142D. Additionally there are two mounting positions for sensors with Pg 13.5 thread and 120 mm (4.72 inch) installation length, e.g. pH or ORP sensors.

Main areas of application are:

  • Drinking water
  • Washwater
  • Process applications
  • Swimming pool water
Your benefits
  • Needle valve to adjust the flow and flow meter for optical control
  • Inductive proximity switch in combination with Liquisys M CCM223/253: a "Flow alarm" can be activated
  • Potential matching pin for pH measurement
  • Cap screwed from below allows calibration of the pH and ORP sensors without sensor removal
Measuring system

A complete measuring system comprises:

  • Flowfit CCA250
  • Chlorine sensor, e.g. CCS142D
  • Measuring cable, e.g. CYK10
  • Transmitter, e.g. Liquiline M

Optional:

  • up to two pH sensors, e.g. Orbisint CPS11D
  • Junction box for cable extension, e.g. RM junction box

Measuring Principle Free chlorine
Application Drinking water, water, waste water, pool, process
Characteristic - Flow through holder with 3 different emplacements : 1x chlorine/chlordioxide/total chlorine sensor and 2x pH/ORP sensor.
Design - Flow through holder made of plexiglas with flow control and proximity switch as alarm relais to the transmitter.
- Three different emplacements
- Calibration directly in the holder because of the screw off calibration cap.
- Optional cleaning device for the chlorine/chlordioxide/total chlorine sensor.
Material Plexiglas (PMMA)
Dimension 85mm x 85mm x 240mm
Process temperature max. 45C
Process pressure max. 4bar

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS120-AS0 EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Threa ..
  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS140-A EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional ..

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS120-AS0 EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head. ..

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS140-A EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assem ..

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS240-N EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor. ..

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS241-N EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor. ..

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS50D-AA11BF EH Memosens CCS50D Digital Sensor for Amperometric measurement of dissolved Chlorine Dioxide (Cl2) in process and drinking water. 0-5 to 0-200 mg/l ClO2 range. Integrated 10k NTC temperature sensor. ..

  • PH ELECTRODES > FM
    CPS11-1AA2ESA EH Orbisint CPS11 pH Analog Electrode for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in hazardous areas. ..

  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CHLORINE ANALIZERS > ASSEMBLY :    31 Items found.
CYH112-AA11A11A1
(365)

ENDRESS+HAUSER  CYH112-AA11A11A1

EH Flexdip CYH112 Modular holder system for water and wastewater sensors and assemblies. Up to 6 bar pressure. Works for floor, wall or rail fixings. UV photometric measuring principle.

CPA640-G311
(129)

ENDRESS+HAUSER  CPA640-G311

EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection.

CYA112-AA11A1AA
(364)

ENDRESS+HAUSER  CYA112-AA11A1AA

EH Flexdip CYA112 Immersion Modular assembly for water and wastewater. UV photometric measuring principle. Stainless steel or PVC versions.

CCA151-AAB1
(367)

ENDRESS+HAUSER  CCA151-AAB1

EH Flowfit CCA151 Flow assembly for disinfection measurement in drinking and process water with chlorine dioxide sensors. Plexiglas Housing. Panel, wall or pipe mounting.

CPA842-AA1E1AAA1
(374)

ENDRESS+HAUSER  CPA842-AA1E1AAA1

EH Unifit CPA842 hygienic process assembly for food and beverage industries. Accepts 12mm pH, ORP, Oxygen (O2), conductivity or cell growth sensors. DN25 or DN50 Process Connection.

CPA442-A1D1B11
(373)

ENDRESS+HAUSER  CPA442-A1D1B11

EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection.

COA250-A
(311)

ENDRESS+HAUSER  COA250-A

EH Cleanfit COA250 flow assembly for Dissolved Oxygen sensors. Wall mounting or unsupported installation in pipes. PVC Material. 871 psi max pressure.

CUA250-B
(184)

ENDRESS+HAUSER  CUA250-B

EH Flowfit CUA250 Turbidity assembly for water and wastewater applications in CUS31/CUS41/CUS51D turbidity sensors. PVC holder body. DN20 or DN50 process connection. Up to 6 bar process pressure.

CPA250-A00
(285)

ENDRESS+HAUSER  CPA250-A00

EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection.

CUA120-A
(183)

ENDRESS+HAUSER  CUA120-A

EH CUA 120 Flange Adapter for mounting of CUS turbidity sensors. PVC or Stainless Steel Material. For mounting on weld-on flange. Up to 6 bar process pressure.

CPA111-00A
(284)

ENDRESS+HAUSER  CPA111-00A

EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors.

CPA510-0110
(282)

ENDRESS+HAUSER  CPA510-0110

EH DipFit CPA510 immersion assembly for DN50 adapters. Includes bayonet lock-mounted electrode holder. Accepts pH and ORP sensors.

CLA111-00A
(306)

ENDRESS+HAUSER  CLA111-00A

EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock.

CPA240-23AA110
(286)

ENDRESS+HAUSER  CPA240-23AA110

EH Flowfit CPA240 Durable Flow assembly for all applications with high temperatures and pressures. Pipe installation. Accepts up to 3 pH and ORP sensors. DN25 or NPT 1/2 Process Connection.

CUA252-AAB111
(393)

ENDRESS+HAUSER  CUA252-AAB111

EH Flowfit CUA252 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Polyethylene holder body. G 1 1/4 process connection. Up to 6 bar process pressure.

CLA140-3A1A110
(305)

ENDRESS+HAUSER  CLA140-3A1A110

EH Dipfit CLA140 immersion assembly for conductivity sensors in applications with aggressive media. Includes flange connection and holder with bayonet lock. Thread G3/4 sensor connection. IP65.

CPA140-231A110
(283)

ENDRESS+HAUSER  CPA140-231A110

EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors.

CYA251-AAA2A111
(396)

ENDRESS+HAUSER  CYA251-AAA2A111

EH Flowfit CYA251 flow assembly for nitrate/SAC, turbidity and oxygen in water and wastewater. UV photometric measuring principle. PVC Material.

CUA262-AAA121
(394)

ENDRESS+HAUSER  CUA262-AAA121

EH Flowfit CUA262 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Stainless steel holder body. Up to 6 bar process pressure.



 
OUA260-BA1B04D1A1A
(326)

ENDRESS+HAUSER  OUA260-BA1B04D1A1A

EH OUA260 flow assembly for absorption, color and turbidity measurements with OUSAFXX and OUSTF10 optical sensors. Ultra-hygienic design.

Page: 1 | 2 | All