Process Control Instruments, Field Devices and Industrial Automation
SKU# (194)

ENDRESS+HAUSER  FMR54-AAAAAAAAA8CGJ




ENDRESS+HAUSER FMR54-AAAAAAAAA8CGJ (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Micropilot FMR54 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids (strong steam, ammonia). High temperature and high pressure applications. DN80 to DN300 Process Connection. 2-wire or 4-wire HART communication. 316L Main wetted parts. FM and CSA approvals.

Part# with Options:        FMR54-AAAAAAAAA8CGJ
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FMR50 & FMR54
Power Supply
(2) Power Supply for EH FMR50/52/54/56
Display & Operation
(3) Display & Operation for EH FMR50/52/54/56
Housing
(4) Housing for EH FMR52/54/57
Electrical Connection
(5) Electrical Connection for EH FMR50/52/54/56
Antenna
(6) Antenna for EH FMR54
Seal
(7) Seal for EH FMR54
Process Connection
(8) Process Connection for EH FMR54

  Availability 10 Days  ]

Application
  • Continuous, non-contact level measurement of liquids, pastes and slurries
  • Rod antenna (FMR53); horn or planar antenna (FMR54)
  • Maximum measuring range: 20 m (66 ft); for FMR54 with planar antenna in stilling well: 38 m (125 ft)
  • Temperature: 196 to +400 C (321 to +752 F)
  • Pressure: 1 to +160 bar (14.5 to +2 320 psi)
  • Accuracy: 6 mm
  • International explosion protection certificates; WHG; marine approvals
  • Linearity protocol (3-point, 5-point)
Your benefits
  • Reliable measurement even for changing product and process conditions
  • HistoROM data management for easy commissioning, maintenance and diagnostics
  • Highest reliability due to Multi-Echo Tracking
  • SIL2 according to IEC 61508, SIL3 in case of homogeneous or heterogeneous redundancy
  • Seamless integration into control or asset management systems
  • Intuitive user interface in national languages
  • Easy proof test for SIL and WHG
Measuring principle

The Micropilot is a "downward-looking" measuring system, operating based on the time-of-flight method (ToF). It measures the distance from the reference point (process connection) to the product surface. Radar impulses are emitted by an antenna, reflected off the product surface and received again by the radar system.

Measuring Principle Level radar
Characteristic / Application Continuous non contact level measurement for use in high-pressure and high-temperature applications,
Horn or planar antenna
Specialities SIL 2 according to IEC 61508,
Safety and reliability with Multi-Echo Tracking
HistoROM
Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Frequency C-band (~6 GHz)
Accuracy +/- 6 mm (0.24 in)
Ambient temperature -40...+80 C
(-40...+176 F)
Process temperature -60...+400C
(-76...+752F)
Process pressure absolute / max. overpressure limit Vacuum...160 bar
(Vacuum...2320 psi)
Main wetted parts 316L
Process connection Flange:
DN80...DN300,
ASME 3"...12",
JIS 10K, 20K
Max. measurement distance 20 m (65 ft)
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, KC
Safety approvals Overfill prevention WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000
Marine approval GL/ ABS/ LR/ BV/ DNV
Options Display,
Customized parameterization
PWIS free
Gastight feed through
Application limits Maximum measuring range is dependent on the tank form and/or application
Free space with nozzle FMR51, FMR52, FMR53
Stilling well with ball valve:
FMR51, FMR52
Hygiene requirements:
FMR52, FMR53
316L or Alloy C non-resistant:
FMR52, FMR53


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> RADAR TRANSMITTERS > FM-CSA :    25 Items found.
FTI55-AAK1RG1W2A1A
(225)

ENDRESS+HAUSER  FTI55-AAK1RG1W2A1A

EH Solicap FTI55 Capacitive Point Level Rod Probe for bulk solids. NPT 1 1/2 Process Connection. PE, PPS, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI56-AAM1RG1W2A1A
(230)

ENDRESS+HAUSER  FTI56-AAM1RG1W2A1A

EH Liquicap FTI56 Capacitive Point Level Rope Probe for bulk solids. R/NPT 1 1/2 Process Connection. PTFE, PA, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI51-AAH1GCJW2A1A
(224)

ENDRESS+HAUSER  FTI51-AAH1GCJW2A1A

EH Liquicap FTI51 Capacitive Point Level Rod Probe for highly viscous liquids. G/NPT 1/2 to G/NPT 1 1/2 Process Connection. PTFE, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FTI52-AAC1GDJW2A1A
(228)

ENDRESS+HAUSER  FTI52-AAC1GDJW2A1A

EH Liquicap FTI52 Capacitive Point Level Rope Probe for highly viscous liquids. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. FEP, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FMI52-A1CGDJV2A1A
(229)

ENDRESS+HAUSER  FMI52-A1CGDJV2A1A

EH Liquicap FMI52 Capacitive Rod Probe for continuous level measurement in liquids (large ranges). HART communication. FEP, PFA or 316L main wetted parts. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. IP66/67. FM and CSA approvals.

FMI51-A1HGCJV2A1A
(223)

ENDRESS+HAUSER  FMI51-A1HGCJV2A1A

EH Liquicap FMI51 Capacitive Rod Probe for continuous level measurement in liquids (extremely high temperatures). HART communication. PFA or 316L main wetted parts. DN50 to D100 Process Connection. IP66. FM and CSA approvals.

FMU40-ANB1A2
(217)

ENDRESS+HAUSER  FMU40-ANB1A2

EH Prosonic FMU40 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 16ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. G/NPT 1 1/2" Process Connection. FM and CSA approvals.

FMP50-AAAAAAAAA1GDJ
(201)

ENDRESS+HAUSER  FMP50-AAAAAAAAA1GDJ

EH Levelflex FMP50 Guided Time-of-Flight Radar for level measurement in liquids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 316L, PPS or Viton main wetted parts. IP66/68 NEMA4X/6P. FM and CSA approvals.

FTI77-A1AVVRG1W2A1A
(227)

ENDRESS+HAUSER  FTI77-A1AVVRG1W2A1A

EH Solicap FTI77 Capacitive Point Level Rod Probe for bulk solids in high temperatures. R 1 1/2 or NPT 1 1/2 Process Connection. Ceramic, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FMU42-AMB1A22A
(218)

ENDRESS+HAUSER  FMU42-AMB1A22A

EH Prosonic FMU42 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 33ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN80 or DN100 Process Connection. FM and CSA approvals.

FMP56-AAAAAALBABGDE
(206)

ENDRESS+HAUSER  FMP56-AAAAAALBABGDE

EH Levelflex FMP56 Guided Time-of-Flight Radar for continuos level measurement in bulk solids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMP51-AAAAAAABA4GDJ
(202)

ENDRESS+HAUSER  FMP51-AAAAAAABA4GDJ

EH Levelflex FMP51 Guided Time-of-Flight Radar for level measurement for highest demands in liquids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 316, 316L, Alloy C, Ceramic or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR50-AAAAAABMGGF
(190)

ENDRESS+HAUSER  FMR50-AAAAAABMGGF

EH Micropilot FMR50 Time-of-Flight Radar for continuos level measurement in liquids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. Encapsulated PVDF or PP clad horn antenna. FM and CSA approvals.

FMU44-AMB1A22A
(220)

ENDRESS+HAUSER  FMU44-AMB1A22A

EH Prosonic FMU44 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 66ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN100 to DN200 Process Connection. FM and CSA approvals.

FMR56-AAAAAABNXR0
(195)

ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

FMP57-AAAAAAAFA4GGE
(207)

ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FTL80-AASAABA1AAJVBJ
(240)

ENDRESS+HAUSER  FTL80-AASAABA1AAJVBJ

EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CSA approvals.

FTL81-AASAABA1ABJVBJ
(245)

ENDRESS+HAUSER  FTL81-AASAABA1ABJVBJ

EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals.

FMP52-AAAAAACBTJK
(203)

ENDRESS+HAUSER  FMP52-AAAAAACBTJK

EH Levelflex FMP52 Guided Time-of-Flight Radar for level measurement with coated probe in aggressive liquids. DN50 to DN100 Process Connection. 2-wire or 4-wire HART communication. 304, 304L, 316, 316L, PTFE or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR57-AAAAAABCA6RGJ1
(196)

ENDRESS+HAUSER  FMR57-AAAAAABCA6RGJ1

EH Micropilot FMR57 Time-of-Flight Radar for continuous non-contact level measurement in bulk solids (highest demands). DN80 to DN100 Process Connection. 2-wire or 4-wire HART communication. 316L, PEEK, PTFE, Polyamid Main wetted parts. FM and CSA approvals.

Page: 1 | 2 | All