Process Control Instruments, Field Devices and Industrial Automation
SKU# (230)

ENDRESS+HAUSER  FTI56-AAM1RG1W2A1A




ENDRESS+HAUSER FTI56-AAM1RG1W2A1A (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Liquicap FTI56 Capacitive Point Level Rope Probe for bulk solids. R/NPT 1 1/2 Process Connection. PTFE, PA, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

Part# with Options:        FTI56-AAM1RG1W2A1A
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FTI56
Inactive Length L3
(2) Inactive Length L3 EH FTI56
Active Probe Length L1
(3) Active Probe Length L1 EH FTI56
Insulation Rope
(4) Insulation Rope for EH FTI56
Process Connection
(5) Process Connection EH FTI56
Electronics & Output
(6) Electronics & Output EH FTI52/56
Housing
(7) Housing EH FTI56
Cable Entry
(8) Cable Entry EH FTI52/56
Type of Probe
(9) Type of Probe EH FTI52/56
Additional Option
(10) Additional Option EH FTI56

  Availability 9 Days  ]

Application

Solicap M is used for point level detection in bulk solids and can be operated in minimum or maximum fail-safe mode.

Due to its robust construction, it can also be used to provide accurate measurements in applications with very high tensile loads (up to 60 kN for rope version) or lateral loads (up to 300 Nm for rod version).

In combination with Fieldgate (for remote interrogation of measured values using internet technology), Solicap M represents an ideal solution for material provisioning and logistical optimization (inventory control).

Your benefits
  • Extremely robust design for harsh process conditions
  • Easy and fast commissioning as calibration is performed at the press of a button
  • Universal application thanks to wide range of certificates and approvals
  • Two-stage overvoltage protection against static discharges from the silo
  • Active buildup compensation for bulk solids that tend to cake
  • Use in safety systems with specific requirements in terms of functional safety to SIL2/SIL3 in conjunction with electronic insert FEI55
  • Increased safety due to permanent automatic monitoring of electronics
  • Reduction in storage costs thanks to easy-to-shorten rod model (for partial insulation) and rope model (for partial and full insulation)
  • Two-point control (e.g. for controlling a handling device)
Measuring principle

The principle of capacitance point level detection is based on the change in capacitance of a capacitor as a result of the probe being covered by bulk solids. The probe and container wall (conductive material) form an electric capacitor. When the probe is in air (1), a certain low initial capacitance is measured. If the container is being filled, the capacitance of the capacitor increases as more of the probe is covered (2), (3).

The point level switch switches when the capacitance C S specified during calibration is reached. In addition, a probe with inactive length ensures that the effects of medium buildup or condensate near the process connection are avoided. A probe with active buildup compensation compensates for the effects of buildup on the probe in the area of the process connection.

Measuring Principle Capacitive Solid
Characteristic / Application Fully / partly isulated rope probe for small-grain / large-grain solids
Simple calibration
Suitable for abrasive media
Very robust probe
Specialities Inactive length
High tensile loading
Extremely robust probe
Supply / Communication 19 ... 253V AC
10 ... 55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11 ... 36V DC
PFM
3-wire
Ambient temperature -50C ... 70C
(-58F ... 158F)
Process temperature -50C ... 180C
(-58F ... 356F)
Process pressure absolute / max. overpressure limit Vacuum ... 25 bar
(Vacuum ... 362 psi)
Main wetted parts PTFE, PA, 316L, Steel
Max. tensile strength 60 kN
Process connection Thread R1 1/2, NPT1 1/2
Flanges from DN50.../ASME 2".../JIS...
Sensor length 0.5m ... 22m
(1.6ft ... 72ft)
Inactive length: 0.1m....1m
(3"...39")
Communication 2- wire 19-253 VAC
DC PNP
Relais DPDT
PFM
3-wire
8/16 mA
Certificates / Approvals ATEX, FM, CSA, IEC Ex, TIIS, NEPSI
Safety approvals SIL
Components PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire: FTC325
Application limits DK min 2


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CAPACITIVE PROBES > FM-CSA :    25 Items found.
FTI55-AAK1RG1W2A1A
(225)

ENDRESS+HAUSER  FTI55-AAK1RG1W2A1A

EH Solicap FTI55 Capacitive Point Level Rod Probe for bulk solids. NPT 1 1/2 Process Connection. PE, PPS, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FTI51-AAH1GCJW2A1A
(224)

ENDRESS+HAUSER  FTI51-AAH1GCJW2A1A

EH Liquicap FTI51 Capacitive Point Level Rod Probe for highly viscous liquids. G/NPT 1/2 to G/NPT 1 1/2 Process Connection. PTFE, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FTI52-AAC1GDJW2A1A
(228)

ENDRESS+HAUSER  FTI52-AAC1GDJW2A1A

EH Liquicap FTI52 Capacitive Point Level Rope Probe for highly viscous liquids. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. FEP, PFA or 316L main wetted parts. IP66/67. FM and CSA approvals.

FMI52-A1CGDJV2A1A
(229)

ENDRESS+HAUSER  FMI52-A1CGDJV2A1A

EH Liquicap FMI52 Capacitive Rod Probe for continuous level measurement in liquids (large ranges). HART communication. FEP, PFA or 316L main wetted parts. G/NPT 3/4 to G/NPT 1 1/2 Process Connection. IP66/67. FM and CSA approvals.

FMI51-A1HGCJV2A1A
(223)

ENDRESS+HAUSER  FMI51-A1HGCJV2A1A

EH Liquicap FMI51 Capacitive Rod Probe for continuous level measurement in liquids (extremely high temperatures). HART communication. PFA or 316L main wetted parts. DN50 to D100 Process Connection. IP66. FM and CSA approvals.

FMU40-ANB1A2
(217)

ENDRESS+HAUSER  FMU40-ANB1A2

EH Prosonic FMU40 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 16ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. G/NPT 1 1/2" Process Connection. FM and CSA approvals.

FMP50-AAAAAAAAA1GDJ
(201)

ENDRESS+HAUSER  FMP50-AAAAAAAAA1GDJ

EH Levelflex FMP50 Guided Time-of-Flight Radar for level measurement in liquids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 316L, PPS or Viton main wetted parts. IP66/68 NEMA4X/6P. FM and CSA approvals.

FTI77-A1AVVRG1W2A1A
(227)

ENDRESS+HAUSER  FTI77-A1AVVRG1W2A1A

EH Solicap FTI77 Capacitive Point Level Rod Probe for bulk solids in high temperatures. R 1 1/2 or NPT 1 1/2 Process Connection. Ceramic, 316L or Steel main wetted parts. IP66/67. FM and CSA approvals.

FMU42-AMB1A22A
(218)

ENDRESS+HAUSER  FMU42-AMB1A22A

EH Prosonic FMU42 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 33ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN80 or DN100 Process Connection. FM and CSA approvals.

FMP56-AAAAAALBABGDE
(206)

ENDRESS+HAUSER  FMP56-AAAAAALBABGDE

EH Levelflex FMP56 Guided Time-of-Flight Radar for continuos level measurement in bulk solids. G 3/4 or MNPT 3/4 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMP51-AAAAAAABA4GDJ
(202)

ENDRESS+HAUSER  FMP51-AAAAAAABA4GDJ

EH Levelflex FMP51 Guided Time-of-Flight Radar for level measurement for highest demands in liquids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 316, 316L, Alloy C, Ceramic or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR50-AAAAAABMGGF
(190)

ENDRESS+HAUSER  FMR50-AAAAAABMGGF

EH Micropilot FMR50 Time-of-Flight Radar for continuos level measurement in liquids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. Encapsulated PVDF or PP clad horn antenna. FM and CSA approvals.

FMU44-AMB1A22A
(220)

ENDRESS+HAUSER  FMU44-AMB1A22A

EH Prosonic FMU44 Ultrasonic Time-of-Flight Transmitter for level measurement in liquids and bulk solids (up to 66ft). 2-wire or 4-wire HART communication. PVDF main wetted parts. DN100 to DN200 Process Connection. FM and CSA approvals.

FMR56-AAAAAABNXR0
(195)

ENDRESS+HAUSER  FMR56-AAAAAABNXR0

EH Micropilot FMR56 Time-of-Flight Radar for continuous non-contact level measurement in solids. DN80 to DN150 Process Connection. 2-wire or 4-wire HART communication. PP or UP Main wetted parts. FM and CSA approvals.

FMP57-AAAAAAAFA4GGE
(207)

ENDRESS+HAUSER  FMP57-AAAAAAAFA4GGE

EH Levelflex FMP57 Guided Time-of-Flight Radar for continuos level measurement in the highest demands in bulk solids. DN50 to DN200 Process Connection. 2-wire or 4-wire HART communication. 304, 316, 316Ti, 316L, PEEK, PPS or PA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FTL80-AASAABA1AAJVBJ
(240)

ENDRESS+HAUSER  FTL80-AASAABA1AAJVBJ

EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CSA approvals.

FTL81-AASAABA1ABJVBJ
(245)

ENDRESS+HAUSER  FTL81-AASAABA1ABJVBJ

EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals.

FMP52-AAAAAACBTJK
(203)

ENDRESS+HAUSER  FMP52-AAAAAACBTJK

EH Levelflex FMP52 Guided Time-of-Flight Radar for level measurement with coated probe in aggressive liquids. DN50 to DN100 Process Connection. 2-wire or 4-wire HART communication. 304, 304L, 316, 316L, PTFE or PFA main wetted parts. IP66/IP68 NEMA4X/6P. FM and CSA approvals.

FMR57-AAAAAABCA6RGJ1
(196)

ENDRESS+HAUSER  FMR57-AAAAAABCA6RGJ1

EH Micropilot FMR57 Time-of-Flight Radar for continuous non-contact level measurement in bulk solids (highest demands). DN80 to DN100 Process Connection. 2-wire or 4-wire HART communication. 316L, PEEK, PTFE, Polyamid Main wetted parts. FM and CSA approvals.

FMR52-AAAAAABOCFK
(193)

ENDRESS+HAUSER  FMR52-AAAAAABOCFK

EH Micropilot FMR52 Time-of-Flight Radar for continuos non-contact level measurement in aggressive liquids. DN50 to DN150 Process Connection. 2-wire or 4-wire HART communication. PTFE-filled and flush-mounted horn antenna. FM and CSA approvals.

Page: 1 | 2 | All