EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

Part# with Options:        FTC325-A2A31
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FTC325
Input & Housing
(2) Input & Housing for EH FTC325
Power Supply
(3) Power Supply for EH FTC325
Switch Output
(4) Switch Output for EH FTC325

  Availability 8 Days  ]

Application
  • Point level detection in tanks containing liquids and silos containing bulk solids. For capacitance sensors, which may also be used in hazardous areas of category ATEX II (1) GD
  • Overfill protection for tanks containing flammable or non-flammable fluids hazardous to water
  • Dry running protection for pumps
  • Two-point control (s with 3-WIRE)
Your benefits
  • Intrinsically safe signal circuit [EEx ia] IIC for using sensors in hazardous areas
  • Calibration using operating keys
  • High functional safety thanks to:
    • fail-safe pulse-frequency modulation (PFM) or 3-WIRE technology
    • Checkable relay function
  • Compact housing for easy series mounting on a standard DIN rail in the cabinet
  • Pluggable terminal blocks make wiring easy
  • Can be used with FEI57S (PFM), FEI53 (3-WIRE)
  • Limit value and alarm relay
  • WHG approval (PFM)
  • Protection against maloperation and manipulation
    • each change of the device configuration leads to signaling via the red LED and a fault message
Measuring principle

Probe and tank (or ground tube/counterpotential) form a capacitor whose capacitance changes with the level of the product.

PFM

The electronic insert FEI57 converts the change of capacitance into a change of frequency, which switches the output relay in the Nivotester FTC325 PFM.

3WIRE

The electronic insert FEI53 converts the change of capacitance into a voltage signal, which switches the output relay in the Nivotester FTC325 3-WIRE.

Characteristic / ApplicationTransmitter with intrinsically safe signal
Calibrating using operating keys
adjustable operating delay
2-wire PFM
3-wire
Rail mounting:
Wide: 45mm (PFM
)Wide: 22,5 mm
With adjustable hysteresis
SpecialitiesMin / Max - changeover
Test/correction key (PFM)
Supply / Communication85V ... 253V AC
20V ... 60V DC
Ambient temperatureSerial montage
-20 C ... 50 C
(-4 F ... 122 F)
Communication2 Relays
Certificates / ApprovalsATEX, FM, CSA, TIIS, INMETRO
Safety approvalsOverfill prevention WHG


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> SWITCHING UNITS > HAZARDOUS LOCATIONS :    47 Items found.
FTW31-A1A2EA0A
(264)

ENDRESS+HAUSER  FTW31-A1A2EA0A

EH Liquipoint FTW31 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTL325N-O1A1
(250)

ENDRESS+HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

FTW325-A2A1A
(266)

ENDRESS+HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

FMI21-A1D1A1
(233)

ENDRESS+HAUSER  FMI21-A1D1A1

EH Liquicap FMI21 Capacitive rod probe for continuos level measurement in conductive liquids. 316L, 1.4404 or PP wetted parts. NPT 1 1/2 or G 1 1/2 Process Connection. ATEX and CSA Approvals.

FTC262-AA32B1
(232)

ENDRESS+HAUSER  FTC262-AA32B1

EH Minicap FTC262 Capacitive rope probe for point level detection in light bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1 1/2 or R 1 1/2 Process Connection. PNP transistor and relay outputs. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

11375Z-RXG1A5A5
(257)

ENDRESS+HAUSER  11375Z-RXG1A5A5

EH 11375Z One rod probe for point level detection of conductive liquids with higher temperatures. 316Ti Rod. PTFE Partial Insulaion. G 1/2 Process Connection. Relay Communication. ATEX Approval.

11362Z-R1AA4A11CA
(259)

ENDRESS+HAUSER  11362Z-R1AA4A11CA

EH 11362Z Double rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FDU90-RG1AA
(211)

ENDRESS+HAUSER  FDU90-RG1AA

EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTM20-AA22A
(254)

ENDRESS+HAUSER  FTM20-AA22A

EH Soliphant FTM20 Vibronic Compact Point level limit switch for bulk solids in dust or hazardous areas. 1 1/4" NPT, 1 1/2" NPT or R Process Connection. ATEX, FM, CSA and IECEx approvals.

FDU91-RG1AA
(212)

ENDRESS+HAUSER  FDU91-RG1AA

EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTL50-AGE2AA1E4A
(237)

ENDRESS+HAUSER  FTL50-AGE2AA1E4A

EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11961Z-RCG1AB5
(256)

ENDRESS+HAUSER  11961Z-RCG1AB5

EH 11961Z One rod probe for point level detection of conductive liquids steam boilers. Highly resistant. 316Ti Rod. G 1/2 Process Connection. Relay Communication. ATEX Approval.

FTL51-AGE2DB1E4A
(241)

ENDRESS+HAUSER  FTL51-AGE2DB1E4A

EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11363Z-R1AA4A111CA
(260)

ENDRESS+HAUSER  11363Z-R1AA4A111CA

EH 11363Z Triple rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FTM21-AM622A
(255)

ENDRESS+HAUSER  FTM21-AM622A

EH Soliphant FTM21 Vibronic Compact Point level limit switch with extension tube for bulk solids in dust or hazardous areas. Stainless Steel Housing (316L). 1 1/4" NPT or 1 1/2" NPT Process Connection. ATEX, FM, CSA and IECEx approvals.

FTL325P-O1A1
(248)

ENDRESS+HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.

FTL50H-AGQ2AC1E4A
(238)

ENDRESS+HAUSER  FTL50H-AGQ2AC1E4A

EH Liquiphant FTL50H Vibronic Compact Point level switch for liquids in food industry (hygienic). Hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.