EH Nivotester FTL825 Vibronic Point level switching unit for Liquiphant FTL80, FTL81 and FTL85. DIN-Rail. FailSafe overfill prevention. 2 SPST safety contact point level, 1 SPST signal contact and 1 SPDT fault contact. SIL3 safety approval. ATEX, FM and CSA approvals.

Part# with Options:        FTL825-AA3A4
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH FTL825
Power Supply
(2) Power Supply for EH FTL825 & FTL325P

  Availability 8 Days  ]

Applications
  • Fail-safe point level detection in liquids
  • For point level switches to zone 0
  • Use in safety systems requiring functional safety to
    SIL3 in accordance with IEC 61508 Ed.2.0 /
    IEC 61511-1 / ISA 84-1
  • Safety-critical systems up to SIL3 in the chemicals, petrochemicals and oil & gas industries where
    • redundant or diverse systems are either not recommended or not possible
    • the longest possible test cycles are desirable
    • proof tests are either not possible or only with great difficulty and expense
Your Benefits
  • SIL3 functional safety due to:
    • internal two-channel design and permanent self-monitoring
    • line monitoring up to the sensor
    • permanent monitoring of the Liquiphant FailSafe point level switch
  • Permanent, visualized LIVE signal
  • Advanced diagnostic function and fault display
  • Verification of the entire measuring system, including downstream control and signal devices, by means of proof test button or remote control
  • Integrated locking function (self-holding)
  • Clear identification ensures there is no risk of confusion (LIVE signal)
  • 4 switching outputs (can be analyzed separately):
    • 2 as level safety contacts based on the quiescent current principle for a redundant output signal
    • 1 x signaling contact (e.g. lamp)
    • 1 x fault-signaling contact as changeover contact
  • Proof test: proof testing interval up to 12 years
Signal transmission

The Nivotester supplies the Liquiphant FailSafe FTL8x point level switch with direct voltage via a two-wire cable. At the same time, it analyzes the current values (4-20 mA discrete) of the Liquiphant and returns a switching signal. The signal inputs of the Nivotester FTL825 are galvanically isolated from the mains and the output and can be ordered as intrinsically safe inputs.

Signal analysis

The Nivotester FailSafe FTL825:

  • Evaluates the current of the point level switch and switches the safety contacts for the level alarm accordingly
  • Switches a signaling contact in addition to the safety contacts
  • Switches a separate fault-signaling contact in the event of a device malfunction
  • Evaluates a dynamic signal (LIVE signal) and indicates the status of this signal using an LED
  • Signals the switching state of the point level switch on the front panel by means of a yellow LED
Operating mode

Minimum/maximum detection (MIN/MAX) can be selected by connection coding on the electronic insert and Nivotester.

MAX = maximum detection:
The output of the Nivotester switches in a safety-oriented manner when the tuning fork is covered (demand mode). Used for overfill protection for example.

MIN = minimum detection:
The output of the Nivotester switches in a safety-oriented manner when the tuning fork is exposed (demand mode). Used for dry running protection and pump protection for example.

Measuring Principle Vibration Liquids
Characteristic / Application FailSafe level transmitter point level. Top hat rail mounting
Connection to FTL80/81/85
Permanent self-monitoring,LIVE-Signal.
Specialities SIL 3 according to IEC61508.
Supply / Communication 85 - 253 VAC/DC
20 - 30 VAC/20-60VDC
Ambient temperature 20 to +60 C
(4 to +140 F)
Communication 2x SPST safety contact point level
1x SPST signal contact
1X SPDT fault contact
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI
Safety approvals Overfill prevention WHG
Leakage Detection
Marine approval GL/ ABS/ LR/ BV/ DNV

  • VIBRATION SWITCHES > FM-CSA
    FTL80-AASAABA1AAJVBJ EH Liquiphant FTL80 Vibronic Compact Point level switch for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. FEL85 electronics; 2 wire (4 to 20mA) output. LED Display. SIL3 safety approval. FM and CS ..

  • VIBRATION SWITCHES > FM-CSA
    FTL81-AASAABA1ABJVBJ EH Liquiphant FTL81 Vibronic Point level switch with extension tube for liquids in hazardous areas. FailSafe overfill prevention. G/R/MNPT 3/4 or G/R/MNPT 1 Process Connection. SIL3 safety approval. FM and CSA approvals. ..

  • VIBRATION SWITCHES > FM-CSA
    FTL85-AASAABN1NBNEZN EH Liquiphant FTL85 Vibronic Coated Point level switch for liquids in hazardous areas. FailSafe overfill prevention. DN25 to DN100 Process Connection. SIL3 safety approval. FM and CSA approvals. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> SWITCHING UNITS > HAZARDOUS LOCATIONS :    47 Items found.
FTW31-A1A2EA0A
(264)

ENDRESS+HAUSER  FTW31-A1A2EA0A

EH Liquipoint FTW31 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

FTL325N-O1A1
(250)

ENDRESS+HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

FTW325-A2A1A
(266)

ENDRESS+HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

FMI21-A1D1A1
(233)

ENDRESS+HAUSER  FMI21-A1D1A1

EH Liquicap FMI21 Capacitive rod probe for continuos level measurement in conductive liquids. 316L, 1.4404 or PP wetted parts. NPT 1 1/2 or G 1 1/2 Process Connection. ATEX and CSA Approvals.

FTC262-AA32B1
(232)

ENDRESS+HAUSER  FTC262-AA32B1

EH Minicap FTC262 Capacitive rope probe for point level detection in light bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1 1/2 or R 1 1/2 Process Connection. PNP transistor and relay outputs. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

11375Z-RXG1A5A5
(257)

ENDRESS+HAUSER  11375Z-RXG1A5A5

EH 11375Z One rod probe for point level detection of conductive liquids with higher temperatures. 316Ti Rod. PTFE Partial Insulaion. G 1/2 Process Connection. Relay Communication. ATEX Approval.

11362Z-R1AA4A11CA
(259)

ENDRESS+HAUSER  11362Z-R1AA4A11CA

EH 11362Z Double rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FDU90-RG1AA
(211)

ENDRESS+HAUSER  FDU90-RG1AA

EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTC325-A2A31
(231)

ENDRESS+HAUSER  FTC325-A2A31

EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

FTM20-AA22A
(254)

ENDRESS+HAUSER  FTM20-AA22A

EH Soliphant FTM20 Vibronic Compact Point level limit switch for bulk solids in dust or hazardous areas. 1 1/4" NPT, 1 1/2" NPT or R Process Connection. ATEX, FM, CSA and IECEx approvals.

FDU91-RG1AA
(212)

ENDRESS+HAUSER  FDU91-RG1AA

EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

FTL50-AGE2AA1E4A
(237)

ENDRESS+HAUSER  FTL50-AGE2AA1E4A

EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11961Z-RCG1AB5
(256)

ENDRESS+HAUSER  11961Z-RCG1AB5

EH 11961Z One rod probe for point level detection of conductive liquids steam boilers. Highly resistant. 316Ti Rod. G 1/2 Process Connection. Relay Communication. ATEX Approval.

FTL51-AGE2DB1E4A
(241)

ENDRESS+HAUSER  FTL51-AGE2DB1E4A

EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

11363Z-R1AA4A111CA
(260)

ENDRESS+HAUSER  11363Z-R1AA4A111CA

EH 11363Z Triple rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

FTM21-AM622A
(255)

ENDRESS+HAUSER  FTM21-AM622A

EH Soliphant FTM21 Vibronic Compact Point level limit switch with extension tube for bulk solids in dust or hazardous areas. Stainless Steel Housing (316L). 1 1/4" NPT or 1 1/2" NPT Process Connection. ATEX, FM, CSA and IECEx approvals.

FTL325P-O1A1
(248)

ENDRESS+HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.

Page: 1 | 2 | 3 | All