Process Control Instruments, Field Devices and Industrial Automation
SKU# (267)

ENDRESS+HAUSER  FQR56-AAAAAVEA1

$1,446.54     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



ENDRESS+HAUSER FQR56-AAAAAVEA1 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Soliwave FQR56 Microwave barrier emitter for non-contact point level detection in bulk solids. Up to 100m measurement range. Suitable as level limit switch. ATEX, CSA and IECEx Approvals.

Part# with Options:        FQR56-AAAAAVEA1
Price with Options:        1,446.54

Options:    

Approval
(1) Approval for EH FQR56 & FQR56
Power Supply
(2) Power Supply for EH FQR56, FDR56 & FTR20
Housing
(3) Housing for EH FQR56
Electrical Connection
(4) Electrical Connection for EH FQR56, FDR56 & FTR20
Process Connection
(5) Process Connection for EH FQR56 & FDR56
Window Transmission
(6) Window Transmission for EH FQR56 & FDR56

  Availability 2 Weeks  ]

Application

The Soliwave microwave barrier uses a contact-free procedure for detection. It can be installed in contai- ners, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside.

Suitable as level limit switch for controlling and counting all types of bulk solids or piece goods (such as bags or boxes). Typical bulk solids include:

  • Wood chips, wood dust or flour
  • Plaster, cement, ash
  • Paper or cardboard shred
  • Gravel, sand
  • Dried powders in general

The FQR56 emitter and FDR56 transceiver are compact transmitters with integrated power unit, and the transceiver has an additional integrated switching amplifier, which ena- bles easy electrical installation onsite.

The microwave barrier has an optional analog output (4 20 mA current output) for analysis of build-up, fouling etc. This allows, for example, the progress of fouling to be evaluated from "uncontaminated" to "contaminated" (the limits can be configured individually).

Your benefits
  • Flush-mounted installation, non-contact installation possible
  • Easy installation using R 11⁄2 or 11⁄2 NPT thread or suitable installation brackets
  • Electronics housing can be rotated by 360, allowing orientation into optimum position after installation
  • Mechanical robustness
    • No wear
    • Process-wetted ceramic sensor diaphragm (optional)
    • Long service life
    • Maintenance-free
  • Indication of the signal strength on the transceiver
  • Adjustable sensitivity
  • Direct connection of the supply voltage (emitter and transceiver separately or together)
  • Mechanically compatible to FQR50/FDR50 microwave barrier, existing process connections can continue to be used; likewise, accessories such as adapter flanges, installation brackets and sight glasses can still be used.
  • Conforms to ATEX, CSA and IECEx
Measuring principle

The FQR56 emitter puts out the microwave signal via an integrated horn antenna. The FDR56 transceiver directly opposite detects this signal and generates the selected output signal (relay, solid-state relay or 4 - 20 mA current output).

The range of the path is influenced by the different types of materials. The attenuation of the microwaves here depends on the electric characteristics of the attenuating material. Materials with the capacity to con- duct electricity, such as metals, reflect the waves, while other materials with lower conductivity only weaken them or are even penetrated. The attenuation of

The complete measuring system for limit detection consists of an FQR56 emitter and a FDR56 transceiver.

Measuring Principle Microwave barrier
Characteristic / Application Transmitter
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination

Installation:
Non-contact installation (transmission window) or front-flush installation (contact)
Specialities Measurement range: max. 100 m
Supply / Communication 85 ... 253VAC
20 ... 30 VDC/ 20 ... 60 VAC
Ambient temperature -40 C...+70 C
(-40 F...+158 F)
Process temperature Non-contact installation: any
Within installation:
-40 C...+70 C (-40 F...+158 F)
With HT-Adapter:
up to +450 C (+842 F)
Process pressure absolute / max. overpressure limit Non-contact installation: any
Within installation:
0.5 bar...6.8 bar (7.2 psi...99 psi) abs.
With HD-Adapter:
up to +21 bar (+305 psi) abs.
Min. density of medium Solid weight: > 10 g/l
Main wetted parts Non-contact installation:
no wetted parts
Within installation:
316Ti or Aluminium;
PTFE or Ceramic
Process connection 1-1/2" R, 1-1/2" G, 1-1/2" NPT
Process connection hygienic Non-contact installation
Certificates / Approvals ATEX, CSA C/US, IEC Ex
Design approvals EN10204-3.1
Options Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55
Components Transceiver: FDR56
Application limits Solid weight: < 10 g/l

  • MICROWAVE BARRIER > HAZARDOUS LOCATIONS
    FDR56-AA1AAAVEA1 EH Soliwave FDR56 Microwave barrier receiver for non-contact point level detection in bulk solids. Up to 100m measurement range. Suitable as level limit switch. ATEX, CSA and IECEx Approvals. ..

  • SWITCHING UNITS > HAZARDOUS LOCATIONS
    FTR325-B1A1 EH Nivotester FTR325 Microwave Barrier Switch amplifier for Soliwave FQR50/FDR50. 1 channel. Relay and DPDT communication. Rail Mounting. SPDT level and SPST alarm/level outputs. ATEX and IECEx Approvals. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> MICROWAVE BARRIER > HAZARDOUS LOCATIONS :    47 Items found.
FTW31-A1A2EA0A
(264)

ENDRESS+HAUSER  FTW31-A1A2EA0A

EH Liquipoint FTW31 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

Configure

$157.82 
FTW32-A1D2EA0A
(265)

ENDRESS+HAUSER  FTW32-A1D2EA0A

EH Liquipoint FTW32 Conductive Point level Rod probe for multipoint detection (up to 5 switch points). G 1 1/2 or NPT1 1/2" Process Connection. ATEX Approval.

Configure

$184.95 
FTL325N-O1A1
(250)

ENDRESS+HAUSER  FTL325N-O1A1

EH Nivotester FTL325N Vibronic Point level switching unit with NAMUR input for rail mounting or single installation in hazardous explosion areas. SIL2 safety approval. ATEX, FM and CSA approvals.

Configure

$191.56 
FTW325-A2A1A
(266)

ENDRESS+HAUSER  FTW325-A2A1A

EH Nivotester FTW325 Conductive Point level switch with intrinsically safe signal circuit. 2 channels. Compact housing for DIN rail. 2 relays (SPDT/DPDT). FM, CSA and ATEX Approvals.

Configure

$228.96 
FTC260-AA2B1
(192)

ENDRESS+HAUSER  FTC260-AA2B1

EH Minicap FTC260 Capacitive rod probe for point level detection in bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1" or R 1" Process Connection. PNP transistor or relay output. IP66. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

Configure

$327.94 
FTE20-AA11AA31
(210)

ENDRESS+HAUSER  FTE20-AA11AA31

EH Soliswitch FTE20 Rotary paddle Point level switch for bulk solids. Extremely robust polymer suitable for dust explosive areas. NPT 1 1/2", NPT 1 1/4" or G 1 1/2" Process Connection. ATEX, FM and IECEx approvals.

Configure

$328.87 
11375Z-RXG1A5A5
(257)

ENDRESS+HAUSER  11375Z-RXG1A5A5

EH 11375Z One rod probe for point level detection of conductive liquids with higher temperatures. 316Ti Rod. PTFE Partial Insulaion. G 1/2 Process Connection. Relay Communication. ATEX Approval.

Configure

$446.05 
11362Z-R1AA4A11CA
(259)

ENDRESS+HAUSER  11362Z-R1AA4A11CA

EH 11362Z Double rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

Configure

$447.23 
FDU90-RG1AA
(211)

ENDRESS+HAUSER  FDU90-RG1AA

EH Prosonic FDU90 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 10ft) with FMU9X. 4-20mA HART communication. PVDF main wetted parts. G/NPT 1 1/2" and G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

Configure

$452.34 
FTC325-A2A31
(231)

ENDRESS+HAUSER  FTC325-A2A31

EH Nivotester FTC325 Capacitive Point Level Switch for liquids and solids. Intrinsically safe signal circuit. 2-wire PFM or 3-wire input. Includes 2 Relays and Compact Housing with DIN-rail mounting. ATEX, FM, CSA and INMETRO approvals.

Configure

$453.99 
FMI21-A1D1A1
(233)

ENDRESS+HAUSER  FMI21-A1D1A1

EH Liquicap FMI21 Capacitive rod probe for continuos level measurement in conductive liquids. 316L, 1.4404 or PP wetted parts. NPT 1 1/2 or G 1 1/2 Process Connection. ATEX and CSA Approvals.

Configure

$498.35 
FTC262-AA32B1
(232)

ENDRESS+HAUSER  FTC262-AA32B1

EH Minicap FTC262 Capacitive rope probe for point level detection in light bulk solids. Polyphenylene sulphide (PPS) wetted parts. NPT 1 1/2 or R 1 1/2 Process Connection. PNP transistor and relay outputs. Optional Aluminium Housing. ATEX , FM and CSA Approvals.

Configure

$513.84 
FDU91-RG1AA
(212)

ENDRESS+HAUSER  FDU91-RG1AA

EH Prosonic FDU91 Ultrasonic Time-of-Flight level and flow sensor for continuous and non-contact measurement (up to 33ft) with FMU9X. 4-wire HART communication. PVDF main wetted parts. G/NPT 1" Process Connection. IP68. ATEX, FM, CSA, INMETRO and IECEx approvals.

Configure

$517.00 
FTL50-AGE2AA1E4A
(237)

ENDRESS+HAUSER  FTL50-AGE2AA1E4A

EH Liquiphant FTL50 Vibronic Compact Point level switch for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

Configure

$525.60 
11961Z-RCG1AB5
(256)

ENDRESS+HAUSER  11961Z-RCG1AB5

EH 11961Z One rod probe for point level detection of conductive liquids steam boilers. Highly resistant. 316Ti Rod. G 1/2 Process Connection. Relay Communication. ATEX Approval.

Configure

$595.98 
FTL51-AGE2DB1E4A
(241)

ENDRESS+HAUSER  FTL51-AGE2DB1E4A

EH Liquiphant FTL51 Vibronic Point level switch with extension tube for liquids measurement in hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

Configure

$599.45 
FTM20-AA22A
(254)

ENDRESS+HAUSER  FTM20-AA22A

EH Soliphant FTM20 Vibronic Compact Point level limit switch for bulk solids in dust or hazardous areas. 1 1/4" NPT, 1 1/2" NPT or R Process Connection. ATEX, FM, CSA and IECEx approvals.

Configure

$611.84 
11363Z-R1AA4A111CA
(260)

ENDRESS+HAUSER  11363Z-R1AA4A111CA

EH 11363Z Triple rod probe for point level detection of conductive liquids in plastic vessels. High resistant. 316Ti Rod. NPT 1 1/2" Process Connection. Relay Communication. ATEX approval.

Configure

$631.07 
FTL325P-O1A1
(248)

ENDRESS+HAUSER  FTL325P-O1A1

EH Nivotester FTL325P Vibronic Point level switching unit for connection to Liquiphant or Soliphant. DIN-Rail. Intrinsically safe signal circuit. SIL3 safety approval. ATEX, FM and CSA approvals.

Configure

$635.21 
FTL50H-AGQ2AC1E4A
(238)

ENDRESS+HAUSER  FTL50H-AGQ2AC1E4A

EH Liquiphant FTL50H Vibronic Compact Point level switch for liquids in food industry (hygienic). Hazardous areas. G/R/NPT 3/4 or G/R/NPT 1 Process Connection. SIL2 and SIL3 safety approvals. ATEX, FM and CSA approvals.

Configure

$644.13 
Page: 1 | 2 | 3 | All