InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(272) Be the First to Review this Item

ENDRESS+HAUSER  CCM253-EK0005

CONTROLLERS / ANALYSIS
TRANSMITTERS


 Information Request
 Shipping Rates
 Volume discount
      



ENDRESS+HAUSER CCM253-EK0005 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

Part# with Options:        CCM253-EK0005
Price with Options:        Please Email us your request for quote   

Options:    

Sensor Input
(1) Sensor Input for EH CCM223/253
Power Supply
(2) Power Supply for EH CCM223/253
Output
(3) Output for EH CCM223/253
Additional Contact
(4) Additional Contact for EH CCM223/253

  Availability 6 Days  ]

Application
  • Drinking water
  • Water treatment
  • Cooling water
  • Gas scrubbers
  • Reverse osmosis
  • Food processing
  • Swimming pool water
Your benefits
  • Field or panel-mounted housing
  • Universal application
  • pH compensation for free chlorine
  • Simple handling
    • Logically arranged menu structure
    • Calibration via CAL button
  • Safe operation
    • Overvoltage (lightning) protection
    • Manual contact control and user-defined alarm configuration

The basic unit can be extended with:

  • 2 or 4 additional contacts for use as:
    • Limit contacts (also for temperature)
    • P(ID) controller for chlorine and pH
    • Timer for simple rinse processes
    • Complete cleaning with Chemoclean
  • Plus package:
    • Manual pH compensation for Cl 2
    • Any current output configuration via table
    • Automatic cleaning start
    • Process monitoring and live check of sensor
  • HART or PROFIBUS PA / DP
  • 2nd current output for temperature, main measured value or actuating variable
  • Current input for flow rate monitoring with controller shut off or for feedforward control
Measuring system

A complete measuring system comprises:

Version 1 (free chlorine and chlorine dioxide)

  • The transmitter Liquisys M CCM223 or CCM253
  • A membrane covered sensor CCS140/141 for Cl2 or CCS240/241 for ClO2 or an open sensor 963 for Cl2
  • A flow assembly CCA250 (not necessary for sensor 963)

and optional:

  • A pH or ORP sensor
  • An INS proximity switch for flow monitoring (omitted with 963 sensor)
  • CMK extension cable for chlorine measurement if required
  • CYK71 extension cable for pH/ORP measurement if required
  • MK extension cable for INS proximity switch if required
  • VBC junction box

Version 2 (total chlorine)

  • The transmitter Liquisys M CCM223 or CCM253
  • A sensor for total chlorine CCS120
  • A flow assembly CCA250 or immersion assembly CYA611
  • A special measuring cable CPK9, PM wire internally

and optional:

  • A pH or ORP sensor
  • An INS proximity switch for flow monitoring (omitted with immersion assembly)
  • CMK extension cable (PM wire internally) for chlorine measurement if required
  • CYK71 extension cable for pH/ORP measurement if required
  • MK extension cable for INS proximity switch if required
  • VBC junction box

Measuring Principle Free chlorine
Application Drinking water, water, waste water, process, pool
Characteristic 4-wire transmitter for chlorine/chlordioxide in a field housing. Simple calibration with the "CAL"-button.
Design Overload protection, alarm relais, different controller functions (P(ID)), temperature display, 2-line display, current output galvanically separated.
Dimension 247mm x 170mm x 115mm
Input Chorine / Chlordioxide and pH/ORP Sensor.
Output - Chlorine/Chlordioxid, pH, Temperature : 0/4-20mA- Profibus- Hart + 0/4-20mA


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS140-A EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assem..


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS141-N EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA..


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS240-N EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor...


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS241-N EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor...


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS120-AS0 EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head...


  • CHLORINE ANALIZERS > ASSEMBLY
    CCA250-A0 EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing...



B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ANALYSIS > TRANSMITTERS :    9 Items found.
CCM223-EK0005 (331) ENDRESS+HAUSER  CCM223-EK0005

EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54.

  

 

 
CPM223-PR0005 (293) ENDRESS+HAUSER  CPM223-PR0005

EH Liquisys CPM223 pH and ORP compact 1 channel 4-wire transmitter for analog and digital glass and ISFET sensors. Simple menu and two-point calibration. Two-line display. IP65. CSA Approval.

  

 

 
CLM223-CD0005 (307) ENDRESS+HAUSER  CLM223-CD0005

EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

  

 

 
CM14-AAK (274) ENDRESS+HAUSER  CM14-AAK

EH Liquiline CM14 1 channel 4-wire transmitter for pH/ORP, conductivity or dissolved oxygen sensors. Memosens hot plug and play. 0/4-20mA output. NEMA4X Polycarbonate housing. IP65. CSA approval.

  

 

 
CLM253-CD0005 (309) ENDRESS+HAUSER  CLM253-CD0005

EH Liquisys CLM253 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

  

 

 
CPM253-PR0005 (294) ENDRESS+HAUSER  CPM253-PR0005

EH Liquisys CPM253 pH and ORP compact 1 channel 4-wire transmitter for analog and digital Memosens sensors. Simple menu and two-point calibration. Two-line display. PC/ABS housing. CSA Approval.

  

 

 
CLM223F-CF0005 (308) ENDRESS+HAUSER  CLM223F-CF0005

EH Liquisys CLM223F Conductivity transmitter for use with all analog conductive and inductive sensors 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

  

 

 
CM42-CAA000EAE00 (130) ENDRESS+HAUSER  CM42-CAA000EAE00

EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals.

  

 

 
CVM40-AA1A1A1A (327) ENDRESS+HAUSER  CVM40-AA1A1A1A

EH Memograph CVM40 1 or 2 channel universal graphic transmitter for inline photometers and data manager. Operates sensors for UV absorption, color, NIR absorption, turbidity and cell growth. IP65.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
CCM253-EK0005

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site