Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CM14-AAK (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Liquiline CM14 1 channel 4-wire transmitter for pH/ORP, conductivity or dissolved oxygen sensors. Memosens hot plug and play. 0/4-20mA output. NEMA4X Polycarbonate housing. IP65. CSA approval.

Part# with Options:        CM14-AAK
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CM14
Sensor Input
(2) Sensor Input for EH CM14

  Availability 4 Days  ]

4-wire-controller based on digital Memosens technology for pH/ORP, conductivity and oxygen

Application

Liquiline CM14 is a 4-wire-controller in compact design for installation in panels or cabinets.

  • Wastewater treatment
  • Water treatment and drinking water monitoring
  • Ion exchanger
  • Surface water monitoring
Your benefits
  • Compact instrument in 48 x 96 mm panel mounted housing
  • Easy to operate
  • Memosens technology
    • Use of precalibrated sensors
    • Safety thanks to active detection of cable break
  • Two contacts for limit contactor
  • Second current output for temperature
Memosens technology

Memosens makes your measuring point safer and more reliable:

  • Non-contact, digital signal transmission enables optimum galvanic isolation
  • No galvanic corrosion
  • Completely watertight
  • Laboratory sensor calibration possible, thus increasing measured value availability
  • Predictive maintenance thanks to recording of sensor data, e.g.:
    • Total hours of operation
    • Hours of operation with very high or very low measured values
    • Hours of operation with high temperatures
    • Number of steam sterilizations
    • Sensor condition

Measuring Principle Sensor ORP / Redox
Application Water, waste water
Characteristic 4-wire transmitter with a two-line display
Measuring principle conductivity transmitter for digital Memosens sensors.
Design panel housing (48x96 mm)
Material panel housing, polycarbonate
front membrane polyester
Dimension 48 mm x 96 mm x 152 mm(built in depth)
3.74x3.74x5.98 inch (built in depth)
temperature sensor Display and current output
Ex certification no
Ingres protection Front IP65 , NEMA 4X, Body IP20
Input One-channel-transmitter
Output 0/4-20mA
Additional Certifications CSA C/US general purpose
UL listed

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..

  • ORP ELECTRODES > FM
    CPF82D-7PA1O EH Orbipac CPF82D ORP compact digital electrode with memosens for processes in mining industries and treatment of wastewater. PTFE diaphragm. NPT 3/4" Threaded connection. Platinum. Optional temperature sensor. IP68. FM Ex Approval. ..

  • OXYGEN SENSORS > HAZARDOUS LOCATIONS
    COS22D-AA1A2B22 EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals. ..

  • OXYGEN SENSORS > HAZARDOUS LOCATIONS
    COS51D-AS800 EH Oxymax COS51D digital memosens amperometric sensor for the measurment of Oxygen (O2) in water, wastewater and utilities applications. Corrosion and moisture resistant. 0 to 2000 hPa measuring range. Thread NPT 3/4 Head. POM sensor body and membrane cap ..

  • PH ELECTRODES > FM
    CPF81D-7NN1O EH Orbipac CPF81D pH compact digital electrode with memosens for processes in mining industries and treatment of wastewater. NPT 3/4" Threaded connection. Optional temperature sensor. IP68. FM Ex approval. ..

  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha ..

  • TURBIDITY SENSORS > GENERAL PURPOSE
    CUS51D-AAC1A2 EH Turbimax CUS51D memosens smart sensor for suspended solids and turbidity measurement in water, wastewater and utilities applications. Self-cleaning functionality. Corrosion and moisture resistant. 0 to 150g/l measurement range. Stainless steel sensor. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ANALYSIS > TRANSMITTERS :    13 Items found.
CCM223-EK0005
(331)

ENDRESS+HAUSER  CCM223-EK0005

EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54.

COM223-DX0005
(312)

ENDRESS+HAUSER  COM223-DX0005

EH Liquisys COM223 Dissolved Oxygen transmitter for use with COS41 and COS61 sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CPM223-PR0005
(293)

ENDRESS+HAUSER  CPM223-PR0005

EH Liquisys CPM223 pH and ORP compact 1 channel 4-wire transmitter for analog and digital glass and ISFET sensors. Simple menu and two-point calibration. Two-line display. IP65. CSA Approval.

CLM223-CD0005
(307)

ENDRESS+HAUSER  CLM223-CD0005

EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

COM253-DX0005
(313)

ENDRESS+HAUSER  COM253-DX0005

EH Liquisys COM253 Dissolved Oxygen field transmitter for use with COS41 and COS61 sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

CCM253-EK0005
(272)

ENDRESS+HAUSER  CCM253-EK0005

EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CLM253-CD0005
(309)

ENDRESS+HAUSER  CLM253-CD0005

EH Liquisys CLM253 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

CPM253-PR0005
(294)

ENDRESS+HAUSER  CPM253-PR0005

EH Liquisys CPM253 pH and ORP compact 1 channel 4-wire transmitter for analog and digital Memosens sensors. Simple menu and two-point calibration. Two-line display. PC/ABS housing. CSA Approval.

CYM290-A1
(356)

ENDRESS+HAUSER  CYM290-A1

EH Liquiline To Go CYM290 portable multiparameter measuring device for Memosens pH, ORP, conductivity and dissolved oxygen sensors. Waterproof. IP66 and IP67.



 
CLM223F-CF0005
(308)

ENDRESS+HAUSER  CLM223F-CF0005

EH Liquisys CLM223F Conductivity transmitter for use with all analog conductive and inductive sensors 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CM42-CAA000EAE00
(130)

ENDRESS+HAUSER  CM42-CAA000EAE00

EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals.

CYM291-A1
(357)

ENDRESS+HAUSER  CYM291-A1

EH Liquiline To Go Ex CYM291 portable multiparameter measuring device for Memosens pH, ORP, conductivity and dissolved oxygen sensors. Waterproof. IP66 and IP67. For hazardous areas to Zone 0. IECEx and ATEX approvals.



 
CVM40-AA1A1A1A
(327)

ENDRESS+HAUSER  CVM40-AA1A1A1A

EH Memograph CVM40 1 or 2 channel universal graphic transmitter for inline photometers and data manager. Operates sensors for UV absorption, color, NIR absorption, turbidity and cell growth. IP65.