EH Liquiline CM14 1 channel 4-wire transmitter for pH/ORP, conductivity or dissolved oxygen sensors. Memosens hot plug and play. 0/4-20mA output. NEMA4X Polycarbonate housing. IP65. CSA approval.

Part# with Options:        CM14-AAK
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CM14
Sensor Input
(2) Sensor Input for EH CM14

  Availability 4 Days  ]

4-wire-controller based on digital Memosens technology for pH/ORP, conductivity and oxygen

Application

Liquiline CM14 is a 4-wire-controller in compact design for installation in panels or cabinets.

  • Wastewater treatment
  • Water treatment and drinking water monitoring
  • Ion exchanger
  • Surface water monitoring
Your benefits
  • Compact instrument in 48 x 96 mm panel mounted housing
  • Easy to operate
  • Memosens technology
    • Use of precalibrated sensors
    • Safety thanks to active detection of cable break
  • Two contacts for limit contactor
  • Second current output for temperature
Memosens technology

Memosens makes your measuring point safer and more reliable:

  • Non-contact, digital signal transmission enables optimum galvanic isolation
  • No galvanic corrosion
  • Completely watertight
  • Laboratory sensor calibration possible, thus increasing measured value availability
  • Predictive maintenance thanks to recording of sensor data, e.g.:
    • Total hours of operation
    • Hours of operation with very high or very low measured values
    • Hours of operation with high temperatures
    • Number of steam sterilizations
    • Sensor condition

Measuring Principle Sensor ORP / Redox
Application Water, waste water
Characteristic 4-wire transmitter with a two-line display
Measuring principle conductivity transmitter for digital Memosens sensors.
Design panel housing (48x96 mm)
Material panel housing, polycarbonate
front membrane polyester
Dimension 48 mm x 96 mm x 152 mm(built in depth)
3.74x3.74x5.98 inch (built in depth)
temperature sensor Display and current output
Ex certification no
Ingres protection Front IP65 , NEMA 4X, Body IP20
Input One-channel-transmitter
Output 0/4-20mA
Additional Certifications CSA C/US general purpose
UL listed

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos..


  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing...


  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing...


  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha..


  • PH ELECTRODES > FM
    CPF81D-7NN1O EH Orbipac CPF81D pH compact digital electrode with memosens for processes in mining industries and treatment of wastewater. NPT 3/4" Threaded connection. Optional temperature sensor. IP68. FM Ex approval...


  • ORP ELECTRODES > FM
    CPF82D-7PA1O EH Orbipac CPF82D ORP compact digital electrode with memosens for processes in mining industries and treatment of wastewater. PTFE diaphragm. NPT 3/4" Threaded connection. Platinum. Optional temperature sensor. IP68. FM Ex Approval...


  • OXYGEN SENSORS > HAZARDOUS LOCATIONS
    COS22D-AA1A2B22 EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals...


  • OXYGEN SENSORS > HAZARDOUS LOCATIONS
    COS51D-AS800 EH Oxymax COS51D digital memosens amperometric sensor for the measurment of Oxygen (O2) in water, wastewater and utilities applications. Corrosion and moisture resistant. 0 to 2000 hPa measuring range. Thread NPT 3/4 Head. POM sensor body and membrane cap..


  • TURBIDITY SENSORS > GENERAL PURPOSE
    CUS51D-AAC1A2 EH Turbimax CUS51D memosens smart sensor for suspended solids and turbidity measurement in water, wastewater and utilities applications. Self-cleaning functionality. Corrosion and moisture resistant. 0 to 150g/l measurement range. Stainless steel sensor. ..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ANALYSIS > TRANSMITTERS :    11 Items found.
CCM223-EK0005
(331)

ENDRESS+HAUSER  CCM223-EK0005

EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54.

COM223-DX0005
(312)

ENDRESS+HAUSER  COM223-DX0005

EH Liquisys COM223 Dissolved Oxygen transmitter for use with COS41 and COS61 sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CPM223-PR0005
(293)

ENDRESS+HAUSER  CPM223-PR0005

EH Liquisys CPM223 pH and ORP compact 1 channel 4-wire transmitter for analog and digital glass and ISFET sensors. Simple menu and two-point calibration. Two-line display. IP65. CSA Approval.

CLM223-CD0005
(307)

ENDRESS+HAUSER  CLM223-CD0005

EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

COM253-DX0005
(313)

ENDRESS+HAUSER  COM253-DX0005

EH Liquisys COM253 Dissolved Oxygen field transmitter for use with COS41 and COS61 sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

CCM253-EK0005
(272)

ENDRESS+HAUSER  CCM253-EK0005

EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CLM253-CD0005
(309)

ENDRESS+HAUSER  CLM253-CD0005

EH Liquisys CLM253 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

CPM253-PR0005
(294)

ENDRESS+HAUSER  CPM253-PR0005

EH Liquisys CPM253 pH and ORP compact 1 channel 4-wire transmitter for analog and digital Memosens sensors. Simple menu and two-point calibration. Two-line display. PC/ABS housing. CSA Approval.

CLM223F-CF0005
(308)

ENDRESS+HAUSER  CLM223F-CF0005

EH Liquisys CLM223F Conductivity transmitter for use with all analog conductive and inductive sensors 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CM42-CAA000EAE00
(130)

ENDRESS+HAUSER  CM42-CAA000EAE00

EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals.

CVM40-AA1A1A1A
(327)

ENDRESS+HAUSER  CVM40-AA1A1A1A

EH Memograph CVM40 1 or 2 channel universal graphic transmitter for inline photometers and data manager. Operates sensors for UV absorption, color, NIR absorption, turbidity and cell growth. IP65.