Process Control Instruments, Field Devices and Industrial Automation
SKU# (276)

ENDRESS+HAUSER  CPA875-AAC1E1CA1A1A




ENDRESS+HAUSER CPA875-AAC1E1CA1A1A (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Cleanfit CPA875 Manual or automatic process retractable assembly for sterile and hygienic applications. Accepts standard (12mm) pH, ORP, oxygen and NIR sensors. DN25/50/65/100 Process Connection.

Part# with Options:        CPA875-AAC1E1CA1A1A
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CPA875
Actuation Unit & Position Switch
(2) Actuation Unit & Position Switch for EH CPA875
Service Chamber/stroke & Sensor
(3) Service Chamber/stroke & Sensor for EH CPA875
Material Seals & Wetted Parts
(4) Material Seals & Wetted Parts for EH CPA875
Material & Surface Wetted Parts
(5) Material & Surface Wetted Parts for EH CPA875
Process Connection
(6) Process Connection for EH CPA875
Connection Service Chamber
(7) Connection Service Chamber for EH CPA875
Version
(8) Version for EH CPA875
Function
(9) Function for EH CPA875

  Availability 4 Weeks  ]

Retractable process assembly for sterile and hygienic applications for in-line measurement with standard 12 mm sensors for parameters such as pH, ORP, oxygen and NIR

Application

The modular retractable assembly has been consistently developed with safety in mind:

  • Safety in operation
  • Safety during cleaning for hygienic processes
  • Protection against contamination in sterile processes

The assembly is therefore perfectly suitable for use in the following industries:

  • Food and beverages
  • Biotechnology
  • Life sciences
  • Special chemicals
Your benefits
  • Maximum availability with minimum maintenance
  • Safe measurement and accurate measured values
  • Higher product quality thanks to reliable measurement results
  • Modular design ensures investment is secure
  • EHEDG-certified assembly: process connection and service chamber
  • Features certified to FDA and USP Class VI

Measuring Principle Sensor ORP / Redox
Application Food and beverages, biotechnology,life sciences,special chemicals
Installation retractable process assembly
Characteristic open and closed tanks, piping
Design -sterile and hygienic stile - manual or pneumatic
Material holder: stainless steel 1.4435 (AISI 316L), seals: EPDM-FDA, FKM-FDA, FFKM-FDA
Dimension immersion depth: 28 - 81 mm
( 1.10 inch - 3.19 inch), depending on process adaption
Process temperature - 10 - 140 C
(14 - 284 F)
Process pressure pneumatic drive: 16 bar, (232 psi)
manual drive: 8 bar, (116 psi)
Connection aseptic DN25 clampable, aseptic DN50 screw-in , clamp ISO 2852,ASME BPE, Varivent N

  • OXYGEN SENSORS > GENERAL PURPOSE
    COS22-AA1A2B22 EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor. ..

  • OXYGEN SENSORS > GENERAL PURPOSE
    COS81D-AAA2CB11 EH Memosens COS81D Digital optical sensor for Oxygen (O2) in Hygienic applications. 0,004 to 30 mg/l measurement range. Stainless steel sensor body. 0 to 190 psi process pressure. Pt100 temperature sensor. ATEX, CSA and IECEx approvals. ..

  • OXYGEN SENSORS > HAZARDOUS LOCATIONS
    COS22D-AA1A2B22 EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals. ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS16D-7AT2C EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals. ..

  • PH ELECTRODES > FM
    CPS11-1AA2ESA EH Orbisint CPS11 pH Analog Electrode for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in hazardous areas. ..

  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ASSEMBLY :    31 Items found.
CYH112-AA11A11A1
(365)

ENDRESS+HAUSER  CYH112-AA11A11A1

EH Flexdip CYH112 Modular holder system for water and wastewater sensors and assemblies. Up to 6 bar pressure. Works for floor, wall or rail fixings. UV photometric measuring principle.

CPA640-G311
(129)

ENDRESS+HAUSER  CPA640-G311

EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection.

CYA112-AA11A1AA
(364)

ENDRESS+HAUSER  CYA112-AA11A1AA

EH Flexdip CYA112 Immersion Modular assembly for water and wastewater. UV photometric measuring principle. Stainless steel or PVC versions.

CCA151-AAB1
(367)

ENDRESS+HAUSER  CCA151-AAB1

EH Flowfit CCA151 Flow assembly for disinfection measurement in drinking and process water with chlorine dioxide sensors. Plexiglas Housing. Panel, wall or pipe mounting.

CPA842-AA1E1AAA1
(374)

ENDRESS+HAUSER  CPA842-AA1E1AAA1

EH Unifit CPA842 hygienic process assembly for food and beverage industries. Accepts 12mm pH, ORP, Oxygen (O2), conductivity or cell growth sensors. DN25 or DN50 Process Connection.

CPA442-A1D1B11
(373)

ENDRESS+HAUSER  CPA442-A1D1B11

EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection.

COA250-A
(311)

ENDRESS+HAUSER  COA250-A

EH Cleanfit COA250 flow assembly for Dissolved Oxygen sensors. Wall mounting or unsupported installation in pipes. PVC Material. 871 psi max pressure.

CUA250-B
(184)

ENDRESS+HAUSER  CUA250-B

EH Flowfit CUA250 Turbidity assembly for water and wastewater applications in CUS31/CUS41/CUS51D turbidity sensors. PVC holder body. DN20 or DN50 process connection. Up to 6 bar process pressure.

CCA250-A0
(173)

ENDRESS+HAUSER  CCA250-A0

EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing.

CPA250-A00
(285)

ENDRESS+HAUSER  CPA250-A00

EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection.

CUA120-A
(183)

ENDRESS+HAUSER  CUA120-A

EH CUA 120 Flange Adapter for mounting of CUS turbidity sensors. PVC or Stainless Steel Material. For mounting on weld-on flange. Up to 6 bar process pressure.

CPA111-00A
(284)

ENDRESS+HAUSER  CPA111-00A

EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors.

CPA510-0110
(282)

ENDRESS+HAUSER  CPA510-0110

EH DipFit CPA510 immersion assembly for DN50 adapters. Includes bayonet lock-mounted electrode holder. Accepts pH and ORP sensors.

CLA111-00A
(306)

ENDRESS+HAUSER  CLA111-00A

EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock.

CPA240-23AA110
(286)

ENDRESS+HAUSER  CPA240-23AA110

EH Flowfit CPA240 Durable Flow assembly for all applications with high temperatures and pressures. Pipe installation. Accepts up to 3 pH and ORP sensors. DN25 or NPT 1/2 Process Connection.

CUA252-AAB111
(393)

ENDRESS+HAUSER  CUA252-AAB111

EH Flowfit CUA252 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Polyethylene holder body. G 1 1/4 process connection. Up to 6 bar process pressure.

CLA140-3A1A110
(305)

ENDRESS+HAUSER  CLA140-3A1A110

EH Dipfit CLA140 immersion assembly for conductivity sensors in applications with aggressive media. Includes flange connection and holder with bayonet lock. Thread G3/4 sensor connection. IP65.

CPA140-231A110
(283)

ENDRESS+HAUSER  CPA140-231A110

EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors.

CYA251-AAA2A111
(396)

ENDRESS+HAUSER  CYA251-AAA2A111

EH Flowfit CYA251 flow assembly for nitrate/SAC, turbidity and oxygen in water and wastewater. UV photometric measuring principle. PVC Material.

CUA262-AAA121
(394)

ENDRESS+HAUSER  CUA262-AAA121

EH Flowfit CUA262 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Stainless steel holder body. Up to 6 bar process pressure.



 
Page: 1 | 2 | All