EH Cleanfit CPA450 Manual retractable assembly for water & wastewater, chemical, pulp & paper and power industries. Accepts 12mm DO, pH and ORP sensors. DN32 Process Connection.

Part# with Options:        CPA450-0B110
Price with Options:        Please Email us your request for quote   

Options:    

Immersion Depth Max & Material
(1) Immersion Depth Max & Material for EH CPA450
Process Connection
(2) Process Connection for EH CPA450
Material & Seal
(3) Material & Seal for EH CPA450
Equipment & Cable Protection
(4) Equipment & Cable Protection for EH CPA450

  Availability 8 Days  ]

Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Application
  • Pulp and paper industry
  • Chemical industry
  • Measurement in fibrous or coating media
  • Tanks and process vessels
  • Pipelines
  • Power plants
  • Wastewater treatment

The retractable assembly permits replacement of pH/ORP or oxygen sensors while the tank is full or under process conditions.

Your benefits
  • Easy installation and removal of the DO/pH/ORP sensor for easy service
  • Sensor cleaning and calibraton without process interruption
  • Process is sealed off reliably by a ball valve made of stainless steel
  • Uses standard and ISFET sensors of 120 mm length
  • 3 immersion depths up to 700 mm (27.5"), adjustable
  • Safety equipment for operation up to 12 bar (175 psi)
  • Integrated rinse and calibration connections
  • Available as stainless steel, alloy C4 and titanium version

Measuring Principle Sensor ORP / Redox
Application Water, waste water, process
Installation Manually retractable assembly
Characteristic Open and closed tank, piping.
Design - manually retractable assembly for 120 mm electrodes - rinse chamber connection G1/4"
Material Stainless steel 1.4404, Hastelloy C4, titanium
Dimension Immersion depth up to 700 mm
(27.56 inch)
Process temperature max. 130C
(266F)
Process pressure max. 4 bar (20 bar)
(58 psi (290 psi))
Connection Thread G 1 1/4", thread NPT 1 1/4"flange DN32 PN16; flange ASME 1 1/4"
Additional Certifications 3.1B EN 10204

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..

  • PH ANALIZERS > CABLES
    CPK9-NHA1A EH CPK9 Measuring Cable for Analog Sensors. IP68 ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH ELECTRODES > FM
    CPS11-1AA2ESA EH Orbisint CPS11 pH Analog Electrode for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in hazardous areas. ..

  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> PH & ORP ANALIZERS > ASSEMBLY :    31 Items found.
CYH112-AA11A11A1
(365)

ENDRESS+HAUSER  CYH112-AA11A11A1

EH Flexdip CYH112 Modular holder system for water and wastewater sensors and assemblies. Up to 6 bar pressure. Works for floor, wall or rail fixings. UV photometric measuring principle.

CPA640-G311
(129)

ENDRESS+HAUSER  CPA640-G311

EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection.

CYA112-AA11A1AA
(364)

ENDRESS+HAUSER  CYA112-AA11A1AA

EH Flexdip CYA112 Immersion Modular assembly for water and wastewater. UV photometric measuring principle. Stainless steel or PVC versions.

CCA151-AAB1
(367)

ENDRESS+HAUSER  CCA151-AAB1

EH Flowfit CCA151 Flow assembly for disinfection measurement in drinking and process water with chlorine dioxide sensors. Plexiglas Housing. Panel, wall or pipe mounting.

CPA842-AA1E1AAA1
(374)

ENDRESS+HAUSER  CPA842-AA1E1AAA1

EH Unifit CPA842 hygienic process assembly for food and beverage industries. Accepts 12mm pH, ORP, Oxygen (O2), conductivity or cell growth sensors. DN25 or DN50 Process Connection.

CPA442-A1D1B11
(373)

ENDRESS+HAUSER  CPA442-A1D1B11

EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection.

COA250-A
(311)

ENDRESS+HAUSER  COA250-A

EH Cleanfit COA250 flow assembly for Dissolved Oxygen sensors. Wall mounting or unsupported installation in pipes. PVC Material. 871 psi max pressure.

CUA250-B
(184)

ENDRESS+HAUSER  CUA250-B

EH Flowfit CUA250 Turbidity assembly for water and wastewater applications in CUS31/CUS41/CUS51D turbidity sensors. PVC holder body. DN20 or DN50 process connection. Up to 6 bar process pressure.

CCA250-A0
(173)

ENDRESS+HAUSER  CCA250-A0

EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing.

CPA250-A00
(285)

ENDRESS+HAUSER  CPA250-A00

EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection.

CUA120-A
(183)

ENDRESS+HAUSER  CUA120-A

EH CUA 120 Flange Adapter for mounting of CUS turbidity sensors. PVC or Stainless Steel Material. For mounting on weld-on flange. Up to 6 bar process pressure.

CPA111-00A
(284)

ENDRESS+HAUSER  CPA111-00A

EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors.

CPA510-0110
(282)

ENDRESS+HAUSER  CPA510-0110

EH DipFit CPA510 immersion assembly for DN50 adapters. Includes bayonet lock-mounted electrode holder. Accepts pH and ORP sensors.

CLA111-00A
(306)

ENDRESS+HAUSER  CLA111-00A

EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock.

CPA240-23AA110
(286)

ENDRESS+HAUSER  CPA240-23AA110

EH Flowfit CPA240 Durable Flow assembly for all applications with high temperatures and pressures. Pipe installation. Accepts up to 3 pH and ORP sensors. DN25 or NPT 1/2 Process Connection.

CUA252-AAB111
(393)

ENDRESS+HAUSER  CUA252-AAB111

EH Flowfit CUA252 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Polyethylene holder body. G 1 1/4 process connection. Up to 6 bar process pressure.

CLA140-3A1A110
(305)

ENDRESS+HAUSER  CLA140-3A1A110

EH Dipfit CLA140 immersion assembly for conductivity sensors in applications with aggressive media. Includes flange connection and holder with bayonet lock. Thread G3/4 sensor connection. IP65.

CPA140-231A110
(283)

ENDRESS+HAUSER  CPA140-231A110

EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors.

CYA251-AAA2A111
(396)

ENDRESS+HAUSER  CYA251-AAA2A111

EH Flowfit CYA251 flow assembly for nitrate/SAC, turbidity and oxygen in water and wastewater. UV photometric measuring principle. PVC Material.

CUA262-AAA121
(394)

ENDRESS+HAUSER  CUA262-AAA121

EH Flowfit CUA262 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Stainless steel holder body. Up to 6 bar process pressure.



 