EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

Part# with Options:        CPS31D-7AC21
Price with Options:        Please Email us your request for quote   

Options:    

Application Range
(1) Application Range for EH CPS31D
Approval
(2) Approval for EH CPS31D

  Availability 7 Days  ]

Application
  • Drinking water
  • Swimming pool water
  • pH compensation for measuring free chlorine
Your benefits
  • One or three ceramic diaphragms
  • Optional salt ring for extended operating life
  • Very low level of ion depletion in electrolyte
  • Gel filling, no electrolyte refill required
  • Can be used up to 4 bar (60 psi) absolute pressure
  • Can be used up to 80 ̊C (176 F)
  • Shaft length 120 mm
  • Memosens plug-in head
  • ESA or GSA plug-in head
Further benefits offered by Memosens technology
  • Maximum process safety thanks to non-contact, inductive signal transmission
  • Digital data transmission ensures data security
  • Very easy to use as sensor-specific data are stored in the sensor
  • Recording of sensor load data in the sensor enables predictive maintenance
Measuring principle pH measurement

The pH value is a measure of the acid or base character of a medium. Depending on the pH value of the medium, the electrode's membrane glass provides an electrochemical potential. This is the result of H + ions selectively penetrating the outer layer of the membrane. As a result, an electrochemical boundary layer forms here with an electric potential. An integrated Ag/AgCl reference system forms the required reference electrode.

The transmitter converts the measured voltage into the corresponding pH value according to the Nernst equation.

Measuring Principle Glass electrode
Application Drinking water and swimming pool water, pH compensation to measure free chlorine
Characteristic Standard applications in water, long lifetime
Measurement range pH 1 - 12
Measuring principle Gel filled reference with one or three diaphragms, option saltring
Design Shaft length 120 mm, with temperature sensor
Material Glass / Ceramics
Dimension Shaft length 120 mm
Process temperature 0 - 80 C (32 - 176 F)
Process pressure 1 - 4 bar abs (15 - 60 psi)
temperature sensor NTC 30k
Ex certification None
Connection Memosens
Ingres protection IP68

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..

  • CHLORINE ANALIZERS > ASSEMBLY
    CCA250-A0 EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA250-A00 EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA640-G311 EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection. ..

  • PH ANALIZERS > CABLES
    CPK9-NHA1A EH CPK9 Measuring Cable for Analog Sensors. IP68 ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> PH ELECTRODES > GENERAL PURPOSE :    47 Items found.
CPS31-1AB2ESA
(378)

ENDRESS+HAUSER  CPS31-1AB2ESA

EH Ceratex CPS31 analog pH glass electrode for application in drinking water and swimming pools. 1 - 12 pH measurement range. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS71-1TB2ESA
(389)

ENDRESS+HAUSER  CPS71-1TB2ESA

EH Ceragel CPS71 Analog pH glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. IP68.

CPS72-0PT2ESA
(390)

ENDRESS+HAUSER  CPS72-0PT2ESA

EH Ceragel CPS72 Analog ORP glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CPF201-C1A
(375)

ENDRESS+HAUSER  CPF201-C1A

EH Purisys CPF201 Analog pH glass electrode for pure and ultrapure water. 1-13 pH measurement range. 43.5psi max pressure. IP68.

CM72-AAADB1C1A1A1
(354)

ENDRESS+HAUSER  CM72-AAADB1C1A1A1

EH Liquiline CM72 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity and oxygen). PEEK Housing. IP67 and IP68. 4-20ma Output. CSA Approval.

COS41-8S
(349)

ENDRESS+HAUSER  COS41-8S

EH Oxymax COS41 2-electrode amperometric sensor for the measurement of Dissolved Oxygen (O2) on water and wastewater applications. 0,05 - 20mg/l measuring range. Integrated NTC temperature sensor.

CCS50D-AA11BF
(350)

ENDRESS+HAUSER  CCS50D-AA11BF

EH Memosens CCS50D Digital Sensor for Amperometric measurement of dissolved Chlorine Dioxide (Cl2) in process and drinking water. 0-5 to 0-200 mg/l ClO2 range. Integrated 10k NTC temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CM82-AAXAB2C1A1A1
(355)

ENDRESS+HAUSER  CM82-AAXAB2C1A1A1

EH Liquiline CM82 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity, oxygen and chlorine). Configurable multiparameter. PEEK Housing. IP67 and IP68. 4-20ma and HART Outputs. Optional Bluetooth. CSA Approval.

CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 