Process Control Instruments, Field Devices and Industrial Automation
SKU# (288)

ENDRESS+HAUSER  CPS92-0PB2ESA




ENDRESS+HAUSER CPS92-0PB2ESA (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

Part# with Options:        CPS92-0PB2ESA
Price with Options:        Please Email us your request for quote   

Options:    

Shaft Length
(1) Shaft Length for EH CPS92
Head
(2) Head for EH CPS92

  Availability 4 Weeks  ]

Application
  • Chemical processes
  • Pulp and paper industry
  • Contaminated media:
    • Solids
    • Emulsions
    • Precipitation reactions
    • Dispersions
Your benefits
  • Open aperture for use in contaminated media
  • Low maintenance thanks to gel filling
  • Long service life thanks to new, stabilized gel
  • Not affected by fluctuations in pressure and temperature
  • Fast response time
Other advantages of Memosens technology
  • Maximum process safety thanks to non-contact, inductive signal transmission
  • Data security thanks to digital data transmission
  • Very easy to use as sensor data saved in the sensor
  • Recording of sensor load data in the sensor enables predictive maintenance with the Memobase Plus CYZ71D
Measuring principle ORP measurement

The ORP potential is a unit of measurement for the state of equilibria between oxidizing and reducing components of a medium. The ORP is measured using a platinum or gold electrode instead of the pH-sensitive glass membrane. Analog to the pH measurement, an integrated Ag/AgCl reference system is used as a reference electrode.

Measuring system

A complete measuring system consists of the following components at least:

  • ORP electrode CPS92D or CPS92
  • Transmitter, e.g. Liquiline CM42, CM44x/R, Mycom S CPM153, Liquisys M CPM2x3
  • Memosens data cable CYK10 for Memosens sensors or CPK9 for analog sensors
  • Immersion, flow or retractable assembly, e.g. Cleanfit CPA871/875

Measuring Principle Sensor ORP / Redox
Application Processapplications, heavy soiled media, emulsions, suspensions, precipitations
Characteristic Very robust, easy cleanable.
Measurement range -1500 mV - +1500 mV
Measuring principle - Gel compact electrode with open aperture - measuring part as platinum cap.
Design All shaft lengths - advanced gel technology
Material Glass electrode and platinum cap.
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature max. 110C (230F)
Process pressure max. 13bar (189psi)
Ex certification Simple operational device, no certification necessary.
Connection TOP68 connection head
Ingres protection IP68

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..


  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing...


  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA871-AACA1ACB1C EH Cleanfit CPA871 Manual or automatic process retractable compact assembly for the water, wastewater and chemical industries. Suitable for vessels and pipes. Accepts standard 12mm pH and ORP sensors. NPT 1 1/2 or DN40/50/80 Process Connection...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA875-AAC1E1CA1A1A EH Cleanfit CPA875 Manual or automatic process retractable assembly for sterile and hygienic applications. Accepts standard (12mm) pH, ORP, oxygen and NIR sensors. DN25/50/65/100 Process Connection...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA473-A3A1A1A7 EH Cleanfit CPA473 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50/65 Process Connection...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA140-231A110 EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA240-23AA110 EH Flowfit CPA240 Durable Flow assembly for all applications with high temperatures and pressures. Pipe installation. Accepts up to 3 pH and ORP sensors. DN25 or NPT 1/2 Process Connection...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA250-A00 EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection...


  • PH & ORP ANALIZERS > ASSEMBLY
    CPA640-G311 EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection...


  • PH ANALIZERS > CABLES
    CPK9-NHA1A EH CPK9 Measuring Cable for Analog Sensors. IP68..



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ORP ELECTRODES > GENERAL PURPOSE :    34 Items found.
CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CCS142D-AAS80
(330)

ENDRESS+HAUSER  CCS142D-AAS80

EH Chloromax CCS142D Digital disinfection memosens sensor for determining free chlorine in drinking water applications. Thread NPT 3/4 head. Amperometric and membrane-covered. Corrosion and moisture resistant. Integrated temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CUE26-A
(320)

ENDRESS+HAUSER  CUE26-A

EH Turbimax CUE26 Handheld turbidity meter for on-site quality control. White Light Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

OUSAF11-AA105A1A10A
(323)

ENDRESS+HAUSER  OUSAF11-AA105A1A10A

EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range.

CCS241-N
(328)

ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CCS141-N
(172)

ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

CAT810-AAD1A11
(337)

ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

CUE24-A
(318)

ENDRESS+HAUSER  CUE24-A

EH Turbimax CUE24 laboratory turbidity meter for quality control. White Light measurement. 0 - 1000 NTU measurement range. RS232 Output. ABS Housing.



 
CLD132-PMV110AA1
(169)

ENDRESS+HAUSER  CLD132-PMV110AA1

EH Smartec CLD132 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt100 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. Relay output and 2-line display. IP67.

Page: 1 | 2 | All