Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CLS21D-C1E1 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Condumax CLS21D 2-electrode Digital conductive conductivity sensor for medium and high measuring ranges. Memosens technology. NPT 1" or G1 Process Connection. IP68. ATEX, FM and CSA Approvals.

Part# with Options:        CLS21D-C1E1
Price with Options:        Please Email us your request for quote   

Options:    

Measuring Range & Cell Constant
(1) Measuring Range & Cell Constant for EH CLS21D
Process Connection
(2) Process Connection for EH CLS21D
Approval
(3) Approval for EH CLS15D & CL21D

  Availability In Stock  ]

Application

Measurement in media with average or high conductivity:

  • Separation of media with average conductivity (milk/water)
  • Separation of media with high conductivity (alkali/water)
  • Drinking water treatment
  • Wastewater treatment

Sensors with temperature probes are used in conjunction with conductivity measuring devices that support automatic temperature compensation:

  • Liquiline CM442/CM444/CM448 (only CLS21D)
  • Liquiline CM42
  • Liquiline CM14 (only CLS21D)
  • Liquisys CLM223/253 (only CLS21)

The resistivity in MΩ cm can also be measured using these transmitters.

Your benefits
  • Different designs for optimum adaptation to the process or mounting location
  • Installation in pipe or flow assembly
  • Compact design
  • With plug-in head (IP68 (CLS21D), IP65 (CLS21)) or fixed cable (IP67)
  • High chemical, thermal and mechanical resistance
  • Manufacturer inspection certificate stating the individual cell constant
Other advantages of Memosens technology
  • Maximum process safety owing to non-contact, inductive signal transmission
  • Data security thanks to digital data transmission
  • Very easy to use as sensor data saved in the sensor
  • Recording of sensor load data in the sensor enables predictive maintenance
Measuring principle

Conductivity of liquids is determined with a measuring arrangement where two electrodes are located in the medium. An alternating voltage that causes a current to flow through the medium is applied at these electrodes. The electrical resistance, or its reciprocal value - conductance G - is calculated based on Ohm's law. The specific conductance κ is determined from the conductance value using the cell constant k, which depends on the sensor geometry.

Measuring system

A complete measuring system comprises the following components at least:

  • The conductively measuring conductivity sensor CLS21D or CLS21
  • A transmitter, e.g. Liquiline M CM42
  • A measuring cable, e.g. Memosens data cable CYK10 or CYK71 for analog sensors

Measuring Principle Conductive
Application Water, waste water, process, media separation, industrial water.
Characteristic 2-electrode system for application in the middle application range.
Measurement range k=1: 10,0 S/cm - 20,0 mS/cm
Measuring principle Conductive conductivity cell with graphite electrodes for applications in the middle range.
Design 2-electrode system with parallel arranged electrodes
Material Cell shaft: PES
Electrodes: graphite
Dimension Diameter: 24 mm
(0.936 inch)
Length: 61 mm
2.37 inch)
Process temperature 100C (212F)
max. 135C(max. 275F) 30 minutes
Process pressure max. 16 bar at 20С
(max. 232psi at 68F)
temperature sensor NTC
Connection Process connection: DN25, DN40, G1", Cable: Memosens connector CYK10
Ingres protection IP68 (connector)

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..


  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex...


  • CONDUCTIVITY ANALIZERS > ASSEMBLY
    CLA111-00A EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS :    20 Items found.
CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

CLS16-3C1A1P
(298)

ENDRESS+HAUSER  CLS16-3C1A1P

EH Condumax CLS16D 2-electrode Analog conductive conductivity sensor for hygienic applications. DN50 Process Connection. IP68. ATEX Approval.

CLS15D-A1A1
(271)

ENDRESS+HAUSER  CLS15D-A1A1

EH Condumax CLS15D 2-electrode Digital conductive conductivity sensor for applications in pure and ultrapure water. Memosens technology. 1/2"NPT or 3/4" NPT Process Connection. IP68. ATEX, FM and CSA Approvals.

CLS50-A1B1
(303)

ENDRESS+HAUSER  CLS50-A1B1

EH Indumax CLS50 Analog toroidal conductivity sensor for standard, hazardous and high-temperature chemistry applications. Inductive cell. PEEK or PFA material. Integrated Pt100 temperature sensor. IP67. ATEX, FM and CSA approvals.

CLS21-C1E4A
(297)

ENDRESS+HAUSER  CLS21-C1E4A

EH Condumax CLS21 2-electrode Analog conductive conductivity sensor for medium and high measuring ranges. NPT 1" or G1 Process Connection. IP65/67. ATEX Approval.

CLS54-AMV5012
(302)

ENDRESS+HAUSER  CLS54-AMV5012

EH Indumax CLS54 Analog toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. DN40 to DN125 Process Connection. Integrated Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm Measurement range. IP68. ATEX, FM and CSA Approvals.

CLS52-A1MV1A1
(168)

ENDRESS+HAUSER  CLS52-A1MV1A1

EH Indumax CLS52 analog toroidal conductivity sensor for hygienic and sterile applications. Stainless steel Pt100 temperature sensor. Inductive measuring cell. 0 - 2000 mS/cm measuring range. IP67. ATEX and qualitity certifications.

CLS50D-AA1B11
(188)

ENDRESS+HAUSER  CLS50D-AA1B11

EH Indumax CLS50D Digital Memosens toroidal inductive conductivity sensor for hazardous and high-temperature chemistry applications. Corrosion and moisture resistant. PEEK or PFA material. Integrated Pt1000 temperature sensor. IP67. ATEX, CSA, FM and IECEx approvals.

CLS16D-3C1P1
(296)

ENDRESS+HAUSER  CLS16D-3C1P1

EH Condumax CLS16D 2-electrode Digital conductive conductivity sensor for hygienic applications. Memosens technology. DN50 Process Connection. IP68. ATEX, FM and CSA Approvals.

COS51D-AS800
(179)

ENDRESS+HAUSER  COS51D-AS800

EH Oxymax COS51D digital memosens amperometric sensor for the measurment of Oxygen (O2) in water, wastewater and utilities applications. Corrosion and moisture resistant. 0 to 2000 hPa measuring range. Thread NPT 3/4 Head. POM sensor body and membrane cap.

CLS30-D1C4A
(167)

ENDRESS+HAUSER  CLS30-D1C4A

EH Condumax W CLS30 2-electrode conductivity sensor for waste water and concentrate applications. Pt100 temperature sensor. 0,1-200,0mS/cm measuring range. 10ft cable connection. PP/PTFE Material. DN25 Process connection. IP65. ATEX and qualitity certifications.

COS22D-AA1A2B22
(178)

ENDRESS+HAUSER  COS22D-AA1A2B22

EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals.

OUSAF44-B0A0
(325)

ENDRESS+HAUSER  OUSAF44-B0A0

EH OUSAF44 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 254-365 nm wavelenght range. 0-2,5 AU measurement range. CIP, SIP, FM and ATEX approvals. IP65.

OUSAF22-B0C0A
(322)

ENDRESS+HAUSER  OUSAF22-B0C0A

EH OUSAF22 Optical sensor combined with OUA260 flow assembly for the measurement of color concentrations in liquids. 390-1100 nm wavelenght range. 0-2,5 AU measurement range. Embedded validation filter. FM and ATEX approvals.

OUSAF21-D0C0D1D1D1A1A
(321)

ENDRESS+HAUSER  OUSAF21-D0C0D1D1D1A1A

EH OUSAF21 Optical sensor for the measurement of low color concentrations in water. 390-1100 nm wavelength range. Embedded validation filter. Female NPT Process Connection. 0,75" nominal diameter. FM and ATEX approvals.

CPS341D-7A1B1
(292)

ENDRESS+HAUSER  CPS341D-7A1B1

EH Ceramax CPS341D Digital non-glass pH memosens electrode for hygienic applications. Corrosion, moisture resistant. 87psi max pressure. IP68. ATEX approval. 0-10pH; 0-140oC; 6 bar.