Process Control Instruments, Field Devices and Industrial Automation
SKU# (301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

$1,396.05     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



ENDRESS+HAUSER CLS54D-AAMV5A2A (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

Part# with Options:        CLS54D-AAMV5A2A
Price with Options:        1,396.05

Options:    

Approval
(1) Approval for EH CLS54D
Process Connection
(2) Process Connection for EH CLS54D
Sensor Material
(3) Sensor Material for EH CLS54D
Cable Length
(4) Cable Length for EH CLS54D
Cable Connection
(5) Cable Connection for EH CLS54D

  Availability 2 Weeks  ]

Application

The CLS54D conductivity sensor is specifically designed for use in hygienic applications in the food, beverage and pharmaceutical industries and in biotechnology. Thanks to its hygiene certificates and its food-safe, virgin PEEK design without any joints or crevices, it meets the strict demands of these industries. The CLS54 is ideal for:

  • Phase separation of product/water and product/product mixtures in pipe systems
  • Control of cleaning in place (CIP) processes in the return line
  • Concentration control in the remaking of CIP cleaning agents
  • Product monitoring in pipes, bottling plants and quality assurance
  • Leakage monitoring

in the following industries:

  • Dairies
  • Breweries
  • Beverages (water, juices, soft drinks)
  • Pharmaceuticals and biotechnology

Use with Liquiline CM42, CM44x and CM14 transmitters.

Your benefits
  • Unique hygienic design, therefore no risk of recontamination
  • Has all the process connections commonly used in the hygiene sector
  • Fast measurement with temperature response time t 90 under 26 s, ensuring safe and efficient phase separation
Other advantages of Memosens technology
  • Maximum process safety
  • Data security thanks to digital data transmission
  • Very easy to use as sensor data saved in the sensor
  • Recording of sensor load data in the sensor enables predictive maintenance
Measuring principle

An oscillator (1) generates an alternating magnetic field in the primary coil (5), which induces a current flow (4) in the medium. The strength of the current depends on the conductivity and thus on the ion concentration in the medium. The current flow in the medium, in turn, generates a magnetic field in the secondary coil (3). The resulting induced current is measured by the receiver (2) and used to determine the conductivity.

Measuring Principle Inductive
Application Food, beverage and pharmaceutical industries and in biotechnology.
Characteristic Specifically intended for use in hygienic applications and especially suitable for following applications:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring.
Measurement range 100 S/cm - 2000 mS/cm Cell constant k: 6,3 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications.
Material In contact with medium: Virgin PEEK
Surface roughness: Ra<0.8m
Process temperature Process temperature: -10C - +125C
(14F - 257F)
Sterilisation: 150C/5 bar (max. 60 min.)
(302F / 72.5 psi)
Process pressure 12 bar(174 psi)/20C(68F)
8 bar(116 psi)/125C(257F)
temperature sensor Pt1000 (class A)with a temperature response time T90 < 27s.
Connection Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50.
Ingres protection IP68/NEMA6P
Additional Certifications FDA, EHEDG, 3-A,Bioreaktivitt (USP class VI part 87 and 88).
Export Info
Made inGermany

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > GENERAL PURPOSE :    34 Items found.
CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

Configure

$416.04 
CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

Configure

$421.29 
COS41-8S
(349)

ENDRESS+HAUSER  COS41-8S

EH Oxymax COS41 2-electrode amperometric sensor for the measurement of Dissolved Oxygen (O2) on water and wastewater applications. 0,05 - 20mg/l measuring range. Integrated NTC temperature sensor.

Configure

$1,190.61 
CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

Configure

$1,347.89 
CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

Configure

$1,554.79 
CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

Configure

$1,674.00 
CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



$1,797.48 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

Configure

$1,874.93 
CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

Configure

$1,895.93 
COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

Configure

$2,064.87 
CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

Configure

$2,073.80 
COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

Configure

$2,082.00 
CUE26-A
(320)

ENDRESS+HAUSER  CUE26-A

EH Turbimax CUE26 Handheld turbidity meter for on-site quality control. White Light Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



$2,126.77 
CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



$2,126.77 
OUSAF11-AA105A1A10A
(323)

ENDRESS+HAUSER  OUSAF11-AA105A1A10A

EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range.

Configure

$2,213.43 
CCS241-N
(328)

ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

Configure

$2,398.12 
CCS141-N
(172)

ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

Configure

$2,428.48 
CAT810-AAD1A11
(337)

ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

Configure

$2,794.01 
CLD132-PMV110AA1
(169)

ENDRESS+HAUSER  CLD132-PMV110AA1

EH Smartec CLD132 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt100 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. Relay output and 2-line display. IP67.

Configure

$2,933.51 
CUS51D-AAC1A2
(182)

ENDRESS+HAUSER  CUS51D-AAC1A2

EH Turbimax CUS51D memosens smart sensor for suspended solids and turbidity measurement in water, wastewater and utilities applications. Self-cleaning functionality. Corrosion and moisture resistant. 0 to 150g/l measurement range. Stainless steel sensor. G1 and NPT3/4 connection. IP68.

Configure

$3,429.87 
Page: 1 | 2 | All