PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(304) Be the First to Review this Item

ENDRESS+HAUSER  CLD134-E00030AA1

ANALYSIS / TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS
GENERAL PURPOSE


 Info/Quote Request
 Shipping Rates
 Volume discount
      



ENDRESS+HAUSER CLD134-E00030AA1 (1)
  • Overview
  • Benefits
  • Specs
  • Documents

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

Part# with Options:        CLD134-E00030AA1
Price with Options:        Please Email us your request for quote   

Options:    

Housing
(1) Housing for EH Smartec S CLD134
Process Connection
(2) Process Connection for EH Smartec S CLD134
Cable Entry
(3) Cable Entry for EH Smartec S CLD134
Power Supply
(4) Power Supply for EH Smartec S CLD134
Output
(5) Output for EH Smartec S CLD134
Additional Option
(6) Additional Option for EH Smartec S CLD134

  Availability 2 Weeks  ]

Hygienic measuring system for conductivity and concentration for applications in the food, beverage and pharmaceutical industries and in biotechnology

Application

The inductive conductivity measuring system is specifically designed for use in hygienic applications in the food, beverage and pharmaceutical industries and in biotechnology. Thanks to its hygiene certificates and its food-safe, virgin PEEK design without any joints or crevices, it meets the strict demands of these industries. Both compact and remote system versions are available. The Smartec CLD134 is ideal for:

  • Phase separation of product/water and product/product mixtures in pipe systems
  • Control of cleaning in place (CIP) processes in the return line
  • Concentration control in the remaking of CIP cleaning agents
  • Product monitoring in pipes, bottling plants and quality assurance
  • Leakage monitoring

in the following industries:

  • Dairies
  • Breweries
  • Beverages (water, juices, soft drinks)
  • Pharmaceuticals and biotechnology
Your benefits
  • Unique hygienic design, therefore no risk of recontamination
  • Has all the hygiene certificates required in the hygiene sector
  • Hygiene-compliant stainless steel transmitter housing
  • Durable thanks to fully encapsulated, sealless design
  • Fast measurement with temperature response time t 90 under 26 s, ensuring safe and efficient phase separation
  • Flexible thanks to a variety of operating options:
    • Keypad
    • HART handheld terminal
    • PROFIBUS PA/DP
    • PC with FieldCare software package (with FDT/DTM technology)
  • Basic version upgradeable by extending functions with remote parameter set configuration (measuring range switching)
Measuring Principle

An oscillator (1) generates an alternating magnetic field in the primary coil (2), which induces a current flow (3) in the medium. The strength of the current depends on the conductivity and thus on the ion concentration in the medium. The current flow in the medium, in turn, generates a magnetic field in the secondary coil (4). The resulting induced current is measured by the receiver (5) and used to determine the conductivity.

Measuring Principle Inductive
Application Food, beverage and pharmaceutical industries and biotechnology.
Characteristic Specifically intended for use in hygienic applications and especially suitable for following applications:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring.
Measurement range 100 S/cm - 2000 mS/cm
cellconstant k : 6.31/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with FDA certified virgin PEEK body including all hygienic certifications.
Material In contact with medium: Virgin PEEK
Surface roughness: Ra<0.9m
Process temperature Process temperature: -10C - 125C
(14F - 257F)
Sterilisation: 150C/5 bar (max. 60 min.)
(302F/72.5 psi)
Process pressure 12 bar(174 psi)/20C(68F)
8 bar(116 psi)/125C(257F)
temperature sensor Pt 1000 (class A)with a temperature response time T90 < 27s.
Connection Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50.
Ingres protection IP67
Output Conductivity, concentration and temperature.0/4-20 mA, HART, Profibus
Additional Certifications FDA, EHEDG, 3A, biological reactivity (USP class VI part 87 and 88)


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > GENERAL PURPOSE :    3 Items found.
CLD18-AGCP (300) ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

  

 

 
CLS54D-AAMV5A2A (301) ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

  

 

 
CLD132-PMV110AA1 (169) ENDRESS+HAUSER  CLD132-PMV110AA1

EH Smartec CLD132 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt100 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. Relay output and 2-line display. IP67.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
CLD134-E00030AA1

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site