Process Control Instruments, Field Devices and Industrial Automation
SKU# (309)

ENDRESS+HAUSER  CLM253-CD0005

CONTROLLERS / ANALYSIS
TRANSMITTERS




ENDRESS+HAUSER CLM253-CD0005 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Liquisys CLM253 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

Part# with Options:        CLM253-CD0005
Price with Options:        Please Email us your request for quote   

Options:    

Sensor Input & Software
(1) Sensor Input & Software for EH CLM223/253
Power Supply
(2) Power Supply for EH C*M223/253
Output
(3) Output for EH C*M223/253
Additional Contact
(4) Additional Contact for EH C*M223/253

  Availability 7 Days  ]

Transmitter for conductive and inductive sensors

Application
  • Ultrapure water
  • Water treatment
  • Ion exchanger and reverse osmosis
  • Cooling water desalination
  • Wastewater
Your benefits
  • Field or panel-mounted housing
  • Easy to use
    • Simple menu structure
    • Calibration using the CAL key
  • Manual contact control and user-defined alarm configuration

The basic device can be extended with:

  • 2 or 4 contacts for use as
    • Limit contacts (also for temperature)
    • P(ID) controller
    • Timer for simple rinse processes or Chemoclean
  • Plus package:
    • Configurable current output characteristic
    • Ultrapure water monitoring (USP/EP, conductive)
    • Concentration Measurement
    • Process check system (PCS): Sensor signal live check
  • HART or PROFIBUS-PA/-DP
  • 2nd current output: temperature, main measured value, actuating variable
  • Current input for flow monitoring or for feedforward control
Measuring system

A complete measuring system comprises:

Version 1 (free chlorine and chlorine dioxide)

  • Transmitter Liquisys M CLM223 or CLM253
  • sensor with or without an integrated temperature sensor
  • If necessary, measuring cable: CYK71 or CPK9 (conductive measurement) or CLK5 (inductive measurement)

and optional:

  • Immersion assembly, e.g. CLA111
  • Extension cable, junction box VBM
  • Weather protection cover CYY101 for field housing

Measuring Principle Conductive
Application Water, waste water, process
Characteristic 4-wire transmitter with a two-line display
Design Conductivity transmitter in a PC/ABS-field housing
Material PC/ABS
Dimension 247x170x115 mm
temperature sensor Display and current output
Ex certification No
Ingres protection IP65
Input One-channel transmitter
Output 0/4-20mA, Hart, Profibus.
Additional Certifications CSA Gen. Purpose.
Export Info
Made inGermany

  • ANALYSIS > TRANSMITTERS
    CLM223-CD0005 EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval. ..

  • CONDUCTIVITY ANALIZERS > ASSEMBLY
    CLA111-00A EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock. ..

  • CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS15-A1A1A EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval. ..

  • CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS16-3C1A1P EH Condumax CLS16D 2-electrode Analog conductive conductivity sensor for hygienic applications. DN50 Process Connection. IP68. ATEX Approval. ..

  • CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS21-C1E4A EH Condumax CLS21 2-electrode Analog conductive conductivity sensor for medium and high measuring ranges. NPT 1" or G1 Process Connection. IP65/67. ATEX Approval. ..

  • PH ANALIZERS > CABLES
    CPK9-NHA1A EH CPK9 Measuring Cable for Analog Sensors. IP68 ..

  • TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS50-A1B1 EH Indumax CLS50 Analog toroidal conductivity sensor for standard, hazardous and high-temperature chemistry applications. Inductive cell. PEEK or PFA material. Integrated Pt100 temperature sensor. IP67. ATEX, FM and CSA approvals. ..

  • TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS52-A1MV1A1 EH Indumax CLS52 analog toroidal conductivity sensor for hygienic and sterile applications. Stainless steel Pt100 temperature sensor. Inductive measuring cell. 0 - 2000 mS/cm measuring range. IP67. ATEX and qualitity certifications. ..

  • TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS54-AMV5012 EH Indumax CLS54 Analog toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. DN40 to DN125 Process Connection. Integrated Pt1000 temperature sensor. 100 ÁS/cm - 2000 mS/cm Measurement range. IP68. ATEX, FM and CSA Approvals. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ANALYSIS > TRANSMITTERS :    13 Items found.
CCM223-EK0005
(331)

ENDRESS+HAUSER  CCM223-EK0005

EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54.

COM223-DX0005
(312)

ENDRESS+HAUSER  COM223-DX0005

EH Liquisys COM223 Dissolved Oxygen transmitter for use with COS41 and COS61 sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CPM223-PR0005
(293)

ENDRESS+HAUSER  CPM223-PR0005

EH Liquisys CPM223 pH and ORP compact 1 channel 4-wire transmitter for analog and digital glass and ISFET sensors. Simple menu and two-point calibration. Two-line display. IP65. CSA Approval.

CLM223-CD0005
(307)

ENDRESS+HAUSER  CLM223-CD0005

EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

COM253-DX0005
(313)

ENDRESS+HAUSER  COM253-DX0005

EH Liquisys COM253 Dissolved Oxygen field transmitter for use with COS41 and COS61 sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

CM14-AAK
(274)

ENDRESS+HAUSER  CM14-AAK

EH Liquiline CM14 1 channel 4-wire transmitter for pH/ORP, conductivity or dissolved oxygen sensors. Memosens hot plug and play. 0/4-20mA output. NEMA4X Polycarbonate housing. IP65. CSA approval.

CCM253-EK0005
(272)

ENDRESS+HAUSER  CCM253-EK0005

EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CPM253-PR0005
(294)

ENDRESS+HAUSER  CPM253-PR0005

EH Liquisys CPM253 pH and ORP compact 1 channel 4-wire transmitter for analog and digital Memosens sensors. Simple menu and two-point calibration. Two-line display. PC/ABS housing. CSA Approval.

CYM290-A1
(356)

ENDRESS+HAUSER  CYM290-A1

EH Liquiline To Go CYM290 portable multiparameter measuring device for Memosens pH, ORP, conductivity and dissolved oxygen sensors. Waterproof. IP66 and IP67.



 
CLM223F-CF0005
(308)

ENDRESS+HAUSER  CLM223F-CF0005

EH Liquisys CLM223F Conductivity transmitter for use with all analog conductive and inductive sensors 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

CM42-CAA000EAE00
(130)

ENDRESS+HAUSER  CM42-CAA000EAE00

EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals.

CYM291-A1
(357)

ENDRESS+HAUSER  CYM291-A1

EH Liquiline To Go Ex CYM291 portable multiparameter measuring device for Memosens pH, ORP, conductivity and dissolved oxygen sensors. Waterproof. IP66 and IP67. For hazardous areas to Zone 0. IECEx and ATEX approvals.



 
CVM40-AA1A1A1A
(327)

ENDRESS+HAUSER  CVM40-AA1A1A1A

EH Memograph CVM40 1 or 2 channel universal graphic transmitter for inline photometers and data manager. Operates sensors for UV absorption, color, NIR absorption, turbidity and cell growth. IP65.