InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(327) Be the First to Review this Item

ENDRESS+HAUSER  CVM40-AA1A1A1A

CONTROLLERS / ANALYSIS
TRANSMITTERS


 Info/Quote Request
 Shipping Rates
 Volume discount
      



ENDRESS+HAUSER CVM40-AA1A1A1A (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Memograph CVM40 1 or 2 channel universal graphic transmitter for inline photometers and data manager. Operates sensors for UV absorption, color, NIR absorption, turbidity and cell growth. IP65.

Part# with Options:        CVM40-AA1A1A1A
Price with Options:        Please Email us your request for quote   

Options:    

Input Signal
(1) Input Signal for EH CVM40
Power Supply
(2) Power Supply for EH CVM40
Housing
(3) Housing for EH CVM40
Operation Language
(4) Operation Language for EH CVM40
Calibration
(5) Calibration for EH CVM40

  Availability 2 Weeks  ]

Graphic transmitter for inline photometers and data manager

Measure, analyze, record, visualize, and communicate

Application

The graphic transmitter for inline photometers & data manager Memograph CVM40 provides information on all photometric process variables. It can operate up to two photometric sensors for UV absorption, color, NIR absorption, turbidity and cell growth. Values are correctly measured, analyzed, and recorded. The measurement data are stored in the 256 MB internal memory & on an SD card or USB stick. CVM40 boasts a modular design, intuitive operation & a comprehensive security concept.

The solution for all your tasks. For example, for:

  • Life science and pharmaceutical industry
  • Food and beverage industry
  • Process measuring technology
  • Environmental applications
Your benefits
  • UL-listed for Canada and USA, 4 approval
  • Memograph CVM40 provides precise measurement values under any condition.
  • Up to 4 optical channels for operation of max. 2 photometric sensors, 2 universal analog channels support multiparameter combined measuring or recording purposes.
  • Menu-guided calibration of photometric sensors.
  • Maintenance and service cycle reminders will pop up and be logged in device history.
  • Security package with person-specific access authorization and electronic signature (FDA 21 CFR Part 11).
  • Integrated Web server, fieldbus (PROFIBUS, Modbus), common standard protocols and interfaces such as USB, TCP/IP, OPC & Ethernet are supported.
Measuring principle

The measuring principle is based on the Lambert-Beer law. There is a linear dependency between the light absorption and the concentration of the absorbing substance. A light source emits radiation through the medium and the transmitted radiation is measured on the detector side. After passing through a filter for wavelength selection, the light intensity is determined by a photodiode and converted into a photo current. The final conversion into transmission (%) or absorption (AU, OD) units is done by the related transmitter.

Measuring system

A complete measuring system comprises:

  • Memograph CVM40
  • An optical sensor, e.g. OUSAF44
  • Flow assembly, e.g. OUA260
  • Cable set, e.g. OUK40

Measuring Principle UV photometric
Application Transmitter for in-line photometers and data manager
Measurement range 0-2,5 AU for Absorption
0-500 FTU or ppm for scattered light
Ingres protection Front panel: IP65 (NEMA4) Rear panel: IP20


  • OPTICAL SENSORS > GENERAL PURPOSE
    OUSAF11-AA105A1A10A EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range...


  • OPTICAL SENSORS > HAZARDOUS LOCATIONS
    OUSAF21-D0C0D1D1D1A1A EH OUSAF21 Optical sensor for the measurement of low color concentrations in water. 390-1100 nm wavelength range. Embedded validation filter. Female NPT Process Connection. 0,75" nominal diameter. FM and ATEX approvals...


  • OPTICAL SENSORS > HAZARDOUS LOCATIONS
    OUSAF22-B0C0A EH OUSAF22 Optical sensor combined with OUA260 flow assembly for the measurement of color concentrations in liquids. 390-1100 nm wavelenght range. 0-2,5 AU measurement range. Embedded validation filter. FM and ATEX approvals...


  • OPTICAL SENSORS > HAZARDOUS LOCATIONS
    OUSAF44-B0A0 EH OUSAF44 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 254-365 nm wavelenght range. 0-2,5 AU measurement range. CIP, SIP, FM and ATEX approvals. IP65...


  • OPTICAL SENSORS > GENERAL PURPOSE
    OUSBT66-AA05A1A EH OUSBT66 Cell growth and biomass sensor for the measurement of Hygienic NIR absorption in fermentation and crystallization applications. 0-4 AU measurement range. LED light source. IP68...


  • OPTICAL ANALIZERS > ASSEMBLY
    OUA260-BA1B04D1A1A EH OUA260 flow assembly for absorption, color and turbidity measurements with OUSAFXX and OUSTF10 optical sensors. Ultra-hygienic design...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ANALYSIS > TRANSMITTERS :    9 Items found.
CCM223-EK0005 (331) ENDRESS+HAUSER  CCM223-EK0005

EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54.

  

 

 
CPM223-PR0005 (293) ENDRESS+HAUSER  CPM223-PR0005

EH Liquisys CPM223 pH and ORP compact 1 channel 4-wire transmitter for analog and digital glass and ISFET sensors. Simple menu and two-point calibration. Two-line display. IP65. CSA Approval.

  

 

 
CLM223-CD0005 (307) ENDRESS+HAUSER  CLM223-CD0005

EH Liquisys CLM223 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

  

 

 
CM14-AAK (274) ENDRESS+HAUSER  CM14-AAK

EH Liquiline CM14 1 channel 4-wire transmitter for pH/ORP, conductivity or dissolved oxygen sensors. Memosens hot plug and play. 0/4-20mA output. NEMA4X Polycarbonate housing. IP65. CSA approval.

  

 

 
CCM253-EK0005 (272) ENDRESS+HAUSER  CCM253-EK0005

EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

  

 

 
CLM253-CD0005 (309) ENDRESS+HAUSER  CLM253-CD0005

EH Liquisys CLM253 Conductivity transmitter for use with all analog conductive and inductive sensors. 0/4-20 mA, HART and PROFIBUS interfaces. PC/ABS Housing. IP65. CSA Approval.

  

 

 
CPM253-PR0005 (294) ENDRESS+HAUSER  CPM253-PR0005

EH Liquisys CPM253 pH and ORP compact 1 channel 4-wire transmitter for analog and digital Memosens sensors. Simple menu and two-point calibration. Two-line display. PC/ABS housing. CSA Approval.

  

 

 
CLM223F-CF0005 (308) ENDRESS+HAUSER  CLM223F-CF0005

EH Liquisys CLM223F Conductivity transmitter for use with all analog conductive and inductive sensors 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval.

  

 

 
CM42-CAA000EAE00 (130) ENDRESS+HAUSER  CM42-CAA000EAE00

EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
CVM40-AA1A1A1A

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site