ENDRESS+HAUSER  CCS241-N




ENDRESS+HAUSER CCS241-N (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

Part# with Options:        CCS241-N
Price with Options:        Please Email us your request for quote   

Options:    

Version
(1) Version for EH CCS241

  Availability 7 Days  ]

Sensors for chlorine dioxide

Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Application

Chlorine dioxide is used for disinfection of water. Its dosing must be carefully controlled to suit the application. Too low a concentration makes the degree of disinfection questionable.

Too high a concentration can result in corrosion effects, impairment of taste or skin irritation.

The CCS240 and CCS241 sensors are applied for measurement of chlorine dioxide in the following fields:

  • Drinking water treatment
  • Pool water treatment
  • Industrial water treatment
Your benefits
  • Measurement in the CCA250 flow assembly is almost independent of flow rate in the range above 30 l/h
  • No zero point calibration necessary. This means complicated installation of an active carbon filter, as in open chlorine dioxide sensors, is not necessary.
  • Measured values are not affected by conductivity fluctuation of the medium.
  • The CCS240 sensor is ready for measurement after a polarisation time of approx. 10 ... 30 minutes. The CCS241 sensor requires 45 ... 90 min.
  • Easy membrane replacement thanks to ready-made membrane head
  • Recalibration intervals approx. 1 ... 4 months under constant operating conditions
Function

The CCS240 and CCS241 sensors are used for measurement of chlorine dioxide. The membrane-covered CCS240 / CCS241 sensors consist of a cathode serving as the working electrode and an anode acting as the counter electrode. These electrodes are immersed in an electrolyte. Electrodes and electrolyte are separated from the medium by a membrane. The membrane prevents the loss of electrolyte and the penetration of contaminants.

To calibrate the measuring system, determine the content of chlorine dioxide using the DPD method. You need a photometer with the pertaining reagents. The determined value is the calibration value for the transmitter.

Measuring Principle

The concentration of chlorine dioxide is determined according to the amperometric measuring principle. The chlorine dioxide (ClO 2 ) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl - ) on the gold cathode. On the silver anode, silver is oxidized to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the chlorine dioxide concentration in the medium. This process takes place within a wide pH and temperature range.

Measuring system

A complete measuring system comprises at least:

  • Chlorine dioxide sensor
  • Liquisys M CCM223/253 transmitter
  • Special measuring cable
  • Flow assembly
  • Reference measuring instrument for determination of chlorine dioxide according to the DPD method

Measuring Principle Chlorine dioxide
Application Drinking water, water, process
Characteristic Amperometric measurement of dissolved chlordioxide
Measurement range 0,01 - 5ppm Chlordioxide
Measuring principle - closed (membrane covered) measuring cell.
- Reduction of chlordioxide (ClO2) to chlorid at the cathode with appr. 120mV.
Design Closed amperometric 2-electrode measuring cell with PTFE membrane.
Material Sensor shaft : PVC
Membrane : PTFE
Membrane cap : PBT (GF30); PVDF
Dimension Diameter : appr. 25mm
Length : 160mm
Process temperature 2C ... 45C
Process pressure 0bar - 1bar
temperature sensor With NTC-temperature sensor
Connection Fixed cable

  • ANALYSIS > TRANSMITTERS
    CCM223-EK0005 EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54. ..

  • ANALYSIS > TRANSMITTERS
    CCM253-EK0005 EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval. ..

  • CHLORINE ANALIZERS > ASSEMBLY
    CCA250-A0 EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing. ..

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS240-N EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CHLORINE SENSORS > GENERAL PURPOSE :    34 Items found.
CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CCS142D-AAS80
(330)

ENDRESS+HAUSER  CCS142D-AAS80

EH Chloromax CCS142D Digital disinfection memosens sensor for determining free chlorine in drinking water applications. Thread NPT 3/4 head. Amperometric and membrane-covered. Corrosion and moisture resistant. Integrated temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CUE26-A
(320)

ENDRESS+HAUSER  CUE26-A

EH Turbimax CUE26 Handheld turbidity meter for on-site quality control. White Light Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

OUSAF11-AA105A1A10A
(323)

ENDRESS+HAUSER  OUSAF11-AA105A1A10A

EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range.

CCS141-N
(172)

ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

CAT810-AAD1A11
(337)

ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

CUE24-A
(318)

ENDRESS+HAUSER  CUE24-A

EH Turbimax CUE24 laboratory turbidity meter for quality control. White Light measurement. 0 - 1000 NTU measurement range. RS232 Output. ABS Housing.



 
CUE21-A1A
(185)

ENDRESS+HAUSER  CUE21-A1A

EH Turbimax CUE21 online turbidity meter with sample condition adjustment. Infrared Measurement. 0 - 1000 NTU measurement range. 100-240 VAC. 4-20 mA or RS-485 output. Automatic ultrasonic cleaning function. ABS Housing. IP66.



 
Page: 1 | 2 | All