InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(329) Be the First to Review this Item

ENDRESS+HAUSER  CCS240-N

ANALYSIS / CHLORINE SENSORS
GENERAL PURPOSE


 Info/Quote Request
 Shipping Rates
 Volume discount
      



ENDRESS+HAUSER CCS240-N (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

Part# with Options:        CCS240-N
Price with Options:        Please Email us your request for quote   

Options:    

Version
(1) Version for EH CCS240

  Availability 7 Days  ]

Sensors for chlorine dioxide

Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Application

Chlorine dioxide is used for disinfection of water. Its dosing must be carefully controlled to suit the application. Too low a concentration makes the degree of disinfection questionable.

Too high a concentration can result in corrosion effects, impairment of taste or skin irritation.

The CCS240 and CCS241 sensors are applied for measurement of chlorine dioxide in the following fields:

  • Drinking water treatment
  • Pool water treatment
  • Industrial water treatment
Your benefits
  • Measurement in the CCA250 flow assembly is almost independent of flow rate in the range above 30 l/h
  • No zero point calibration necessary. This means complicated installation of an active carbon filter, as in open chlorine dioxide sensors, is not necessary.
  • Measured values are not affected by conductivity fluctuation of the medium.
  • The CCS240 sensor is ready for measurement after a polarisation time of approx. 10 ... 30 minutes. The CCS241 sensor requires 45 ... 90 min.
  • Easy membrane replacement thanks to ready-made membrane head
  • Recalibration intervals approx. 1 ... 4 months under constant operating conditions
Function

The CCS240 and CCS241 sensors are used for measurement of chlorine dioxide. The membrane-covered CCS240 / CCS241 sensors consist of a cathode serving as the working electrode and an anode acting as the counter electrode. These electrodes are immersed in an electrolyte. Electrodes and electrolyte are separated from the medium by a membrane. The membrane prevents the loss of electrolyte and the penetration of contaminants.

To calibrate the measuring system, determine the content of chlorine dioxide using the DPD method. You need a photometer with the pertaining reagents. The determined value is the calibration value for the transmitter.

Measuring Principle

The concentration of chlorine dioxide is determined according to the amperometric measuring principle. The chlorine dioxide (ClO 2 ) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl - ) on the gold cathode. On the silver anode, silver is oxidized to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the chlorine dioxide concentration in the medium. This process takes place within a wide pH and temperature range.

Measuring system

A complete measuring system comprises at least:

  • Chlorine dioxide sensor
  • Liquisys M CCM223/253 transmitter
  • Special measuring cable
  • Flow assembly
  • Reference measuring instrument for determination of chlorine dioxide according to the DPD method

Measuring Principle Chlorine dioxide
Application Waste water, pool
Characteristic Amperometric measurement of dissolved Chlordioxide
Measurement range 0,05 - 20ppm Chlordioxide;
Measuring principle - closed (membrane covered) measuring cell.
- Reduction of Chlordioxid (ClO2) to Chlorid at the cathode at appr. 120mV.
Design Closed amperometric 2-electrode measuring cell with PTFE membrane
Material Sensor shaft : PVC
Membrane : PTFE
Membrane cap : PBT (GF30); PVDF
Dimension Diameter : appr. 25mm
Length : 160mm
Process temperature 2C ... 45C
Process pressure 0bar - 1bar
temperature sensor With NTC-temperature sensor
Connection Fixed cable


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS241-N EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor...


  • ANALYSIS > TRANSMITTERS
    CCM253-EK0005 EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval...


  • ANALYSIS > TRANSMITTERS
    CCM223-EK0005 EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54...


  • CHLORINE ANALIZERS > ASSEMBLY
    CCA250-A0 EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CHLORINE SENSORS > GENERAL PURPOSE :    5 Items found.
CCS142D-AAS80 (330) ENDRESS+HAUSER  CCS142D-AAS80

EH Chloromax CCS142D Digital disinfection memosens sensor for determining free chlorine in drinking water applications. Thread NPT 3/4 head. Amperometric and membrane-covered. Corrosion and moisture resistant. Integrated temperature sensor.

  

 

 
CCS140-A (171) ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

  

 

 
CCS120-AS0 (170) ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.

  

 

 
CCS241-N (328) ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

  

 

 
CCS141-N (172) ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
CCS240-N

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site