InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(330) Be the First to Review this Item

ENDRESS+HAUSER  CCS142D-AAS80

ANALYSIS / CHLORINE SENSORS
GENERAL PURPOSE


 Information Request
 Shipping Rates
 Volume discount
      



ENDRESS+HAUSER CCS142D-AAS80 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Chloromax CCS142D Digital disinfection memosens sensor for determining free chlorine in drinking water applications. Thread NPT 3/4 head. Amperometric and membrane-covered. Corrosion and moisture resistant. Integrated temperature sensor.

Part# with Options:        CCS142D-AAS80
Price with Options:        Please Email us your request for quote   

Options:    

Measuring Range
(1) Measuring Range for EH CCS240
Approval
(2) Approval for EH CCS240

  Availability 8 Days  ]

Digital sensor with Memosens technology for determining free chlorine

Membrane-covered amperometric sensor for process and drinking water applications

Application

Oxidants such as chlorine or inorganic chlorine compounds are used to disinfect water. They must be dosed immediately, depending on the operating conditions. If the concentrations are too low, this could jeopardize the disinfection process. On the other hand, concentrations which are too high can cause corrosion, skin irritation and affect the taste of the water.

The CCS142D chlorine sensor is used to measure free chlorine in the following areas:

  • Drinking water
  • Process water
  • Industrial water treatment
Your benefits
  • Sensor with digital signal processing:
    • Not sensitive to electromagnetic interference thanks to digital communication with the transmitter
    • Calibration data saved in the sensor, making it possible to calibrate at any transmitter or location and install subsequently at the measuring point
  • Ultimate measuring reliability:
    • Measurement practically independent of the flow at flow velocities above 15 cm/s (~0.5 ft/s)
    • Long calibration and maintenance intervals
    • No change in measured value in the event of fluctuations in conductivity
  • Membrane-covered sensor, therefore:
    • Easy membrane replacement thanks to prefabricated membrane head
    • Minimum maintenance
  • Zero-point calibration not required. No complex installation of an activated carbon filter, as found with open chlorine sensors
Measuring Principle

The concentration of free chlorine is determined according to the amperometric measuring principle. The hypochlorous acid (HOCl) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl - ) on the gold cathode. On the silver anode, silver is oxidized to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the free chlorine concentration in the medium under constant conditions. The concentration of hypochlorous acid in the medium depends on the pH value. This dependence can be compensated by measuring the pH value in the flow assembly.

The transmitter transforms the current signal into the measuring unit concentration in mg/l.

Function

The membrane-covered sensor CCS142D consists of a cathode (working electrode) and an anode (counterelectrode) in an electrolyte which is separated from the medium by a membrane. The membrane prevents the electrolyte from leaking and protects against contaminant penetration.

The measuring system is calibrated by determining the free chlorine based on the DPD method (photometric method). The calibration value determined is entered in the transmitter.

Measuring system

A complete measuring system consists of:

  • A CCS142D chlorine sensor
  • An assembly, e.g. Flowfit CCA250
  • A Memosens data cable CYK10
  • A transmitter, e.g. Liquiline CM44x

Optional:

  • RM junction box for cable extension
  • When using the assembly CCA250: additional sensor(s), e.g. pH sensor CPS71D

Measuring Principle Free chlorine
Application Water treatment (drinking water, service water, process water, distribution network)
Characteristic amperometric measurement of free chlorine
Measurement range 0,01..5 mg/l / 0,05..20mg/l free chlorine
Measuring principle membrane-covered amperometric sensor
Design Sensor for use in flow cell (CCA250)
or for immersion use (thread NPT 3/4 on top)
Memosens-technology.
Material Sensor shaft: PVC. Membrane: PTFE
Dimension Diameter sensor body: 25mm
diamter sealing seat for flow cell: 31mm
length overall: 148mm
Process temperature 0..45C, not freezing
Process pressure ambient to 2bar abs
temperature sensor Integrated (Memosens)
Connection Memosens


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS140-A EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assem..


  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS141-N EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA..


  • CHLORINE ANALIZERS > ASSEMBLY
    CCA250-A0 EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing...



B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CHLORINE SENSORS > GENERAL PURPOSE :    5 Items found.
CCS140-A (171) ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

  

 

 
CCS240-N (329) ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

  

 

 
CCS120-AS0 (170) ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.

  

 

 
CCS241-N (328) ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

  

 

 
CCS141-N (172) ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
CCS142D-AAS80

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site